TECHNICAL DETAILS GGP6.6
Total Unit
GAS
OPERATING PRESSURE
TOTAL HEAT INPUT
NATURAL G20
20mb/8” W.G.
5.500 KW = 18767 Btu/h
BUTANE G30
29mb/11.2” W.G.
5.500 KW = 18767 Btu/h
PROPANE G31
37mb/14.8” W.G.
5.500 KW = 18767 Btu/h
G25
25mb/10” W.G.
5.000 KW = 17061 Btu/h
GAS RATE
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
0.582 M³/HR 20.553 FT³/HR
BUTANE G30
0.184 M³/HR 6.505 FT³/HR
0.957 LB/HR 0.434 KG/HR
PROPANE G31
0.243 M³/HR 8.565 FT³/HR
0.941 LB/HR 0.427 KG/HR
G25 @ 25mb
0.615 M³/HR 21.719 FT³/HR
INJECTORS
Natural G20 = INJECT 115
Butane G30 = INJECT 85
Propane G31 = INJECT 85
G25 @ 25mb = INJECT 115