background image

 

 

Parry

-British Built for Purpose 

IN101-6

 

  

Safety Instructions 

 

 

IMPORTANT 

 

PLEASE READ INSTRUCTIONS FULLY BEFORE USE 

INSTALLATION INSTRUCTIONS 

 

THIS APPLIANCE IS ONLY FOR PROFESSIONAL USE AND MUST ONLY BE USED BY QUALIFIED 
PEOPLE. 
 

Attention should be drawn to the fact that parts of this unit by necessity, will get VERY HOT, 
and will cause burns if touched accidentally. Therefore, it is the responsibility of the 
supervisor or equivalent to provide SUITABLE PROTECTIVE CLOTHING for the user. 

 
THIS APPLIANCE MUST BE FITTED AND TESTED BY A REGISTERED FITTER BEFORE USE. 
 

The unit should be installed in compliance with the INSTALLATION INSTRUCTIONS and the 
NATIONAL REGULATIONS in force at the time. Particular attention should be paid to the Gas 
Safety (Installation and Use) Regulations and the Health and Safety at Work Act. 
 
All commercial gas catering equipment is recommended to be mounted below an extraction 
canopy. Please consult a ventilation engineer or refer to Guidelines DW172 to calculate the 
ventilation requirements for cooking areas containing different pieces of gas catering 
equipment. 

 

Each appliance requires a flow of fresh air for combustion. Under no circumstances should 
air vents on the appliances, or air vents installed by the fitter in the room of the appliance to 
supply combustion air, be altered or omitted in any way. 
 
To prevent shocks, all appliances whether gas or electric, must be earthed. 
 

 ANY GAS CONVERSIONS NEEDED TO BE MADE TO THE PRODUCT MUST BE CARRIED OUT 
BY A GAS SAFE REGISTERED ENGINEER 
 

To avoid scratching the highly polished exterior surface of this equipment whilst in transit, 
the protective film on the exterior surfaces has NOT been removed. 
 
It is IMPORTANT that this protective film is peeled off before the equipment is used. 

 

 

Summary of Contents for AG2H

Page 1: ...Instruction Manual AG2H AG2HP 2 Burner Gas Boiling Hob...

Page 2: ...opment of our highly skilled artisan workforce means that our clients have genuine peace of mind that they are buying hand crafted quality products supported by five star customer service All Parry pr...

Page 3: ...Maintenance Instructions 8 Fault Finding 9 Replacement Parts 9 Natural Gas Conversion Instructions 10 LPG Conversion Instructions 11 Conversion Procedure 12 13 Technical Information 14 Service Informa...

Page 4: ...y duty enamelled pan supports are ideal for heavy pots and pans while the high grade stainless steel is both durable and easy to clean AG2HP Ideal for smaller catering establishments the Parry LPG gas...

Page 5: ...atural KW Propane Butane 11 1 n a n a 8 7 BTU Natural BTU Propane Butane 37 873 n a n a 29 864 Input Gas Connection BSP Male BSP Male GAS INPUT PRESSURE Natural GAS INPUT PRESSURE Propane GAS INPUT PR...

Page 6: ...d the Health and Safety at Work Act All commercial gas catering equipment is recommended to be mounted below an extraction canopy Please consult a ventilation engineer or refer to Guidelines DW172 to...

Page 7: ...appliance This should not be blocked at any time This appliance should be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health...

Page 8: ...nts in force and be CE marked of a metal braided construction suitable for commercial catering equipment The hoses should be periodically examined and replaced as necessary The tube or hose shall be f...

Page 9: ...up to a maximum of 295mm diameter This ensures that there is satisfactory combustion and the pan is stable as it sits on the finger of the pan support We advise these appliances should not be left una...

Page 10: ...ne and clean all burner and flame retention ports Using a combination of brushes remove dust and lint from within the primary air ports venture and burners Check the burner aeration to ensure it is cl...

Page 11: ...ocouple Burner goes out when turned to low Blockage in tap Clean and re grease Irregular flame Burner ring cap not correctly located or low pressure Relocate and check pressure at test point Replaceme...

Page 12: ...in accordance with all current regulations enforced to run on the following gases only Nat Gas G20 20mbar 8 W G PLEASE NOTE This conversion must be carried out by a Gas Safe Registered Engineer This...

Page 13: ...ested in accordance with all current regulations enforced to run on the following gases only Propane G31 37mbar 14 8 W G PLEASE NOTE This conversion must be carried out by a Gas Safe Registered Engine...

Page 14: ...the gas supply before commencing conversion Remove pan support and burner caps Lift off aluminium burner plates Remove the solid top plate Using an 10mm spanner remove burner injector Replace with inj...

Page 15: ...y and replace with low rate screw from the conversion kit Connect the unit back to the gas supply Test for gas soundness Replace the facia and knobs accordingly When comversion is complete addix new d...

Page 16: ...HR BURNER LOW RATE FLOWRATE HEAT INPUT NATURAL G20 0 126 M HR 1 176 KW PROPANE G31 0 029 M HR 0 700 KW Total Unit GAS OPERATING PRESSURE TOTAL HEAT INPUT NATURAL G20 20mb 8 W G 11 113 KW 37918 Btu h P...

Page 17: ...person Enhanced 2 Years Warranty Parry Catering Midlands Ltd offer an enhanced warranty of two years including parts and labour on all of the Parry manufactured products To take advantage of this you...

Page 18: ...Parry British Built for Purpose IN101 6 16 Exploded View...

Page 19: ...CP600ISP 2 7 320MM Thermocouple 2 x M8X1 Locknuts THCP320ISP 2 8 Nat NAT GAS 09920909 C BP COPBPS 85 4 8 LPG CPB 09902187 COPBPS 50 4 9 COPRECI M14 x 1 5 NUT COPM14NUT 4 10 GAS KNOB 5 16 DIA SHAFT ULY...

Page 20: ...at Parry s discretion whether to repair or replace the equipment The warranty only applies if the equipment has been used in a professional manner following the manufacturer s instructions and mainte...

Page 21: ...levelling and setting up of doors on a six burner cooker Excessive carbon build up on griddle plates or overuse of lava rock on chargrills Recommended use by Parry no more than 2kg Appliances that hav...

Page 22: ...Parry British Built for Purpose IN101 6 20 Disposal Recycling The packaging should be disposed of in accordance with the regulations in force...