10
Natural Gas Conversion Instructions
Please note conversion kits sold separately
Product:
AG2HP
–
2 Burner Gas Boiling Hob LPG
These instructions can be used for converting from LPG to Natural Gas
LPG units are designed and tested in accordance with all current regulations enforced to run
on the following gases only
Nat Gas G20 @ 20mbar 8” W.G.
PLEASE NOTE
This conversion must be carried out by a Gas Safe Registered Engineer.
This conversion kit includes
Description
Product Code
Quantity
Hob valve
bypass screw
NAT GAS Hob valve bypass
screw stamped with 85
COPBPS - 85
2
Hob burner
injector
NAT GAS Hob Burner
Injector stamped with 185
HOBINJECT185
2
Labels
NAT. GAS ONLY + G20
1
Instructions
CONVIN21-4