INSTRUCTION REF: IN146-7
DATE - 25/02/16
PAGE 7 of 14
www.parry.co.uk
To gain entry to components-
Remove top flue cover (4 screws on top), next remove 2 screws from front of right
hand side panel, pull off gas control knob, remove 3 screws from rear of side panel
and panel will lift off.
To change the thermocouple-
Thermo-couple is retained by pilot/ignition bracket. Loosen the 2 screws on this
bracket, to withdraw thermocouple disconnect nut on back of gas tap to remove
thermocouple, assemble in reverse.
To replace ignition electrode-
Loosen the 2 screws on pilot/ignition bracket and withdraw electrode, disconnect
lead.
To clean pilot injector-
Remove the 2 screws on bracket. Remove pilot head from inside cooking area.
Clean and reassemble in reverse order.
To replace gas tap/ffd unit-
Undo inlet and outlet unions, remove thermocouple from rear of tap unit, undo
locknut on tap bracket and remove tap/ffd. Reassemble in reverse order.
Check for gas soundness and correct operation of flame failure unit. Refit side panel
and flue cover.
PLEASE NOTE:
IF THE BURNER PLAQUES ARE CRACKED THEY WILL NOT BE COVERED BY
WARRANTY