PARRY 7072 Instructions Manual Download Page 6

INSTRUCTION REF: IN146-7 
DATE  - 25/02/16 
PAGE 6 of 14 
 

 

www.parry.co.uk 

 
It is recommended the Grill be given approximately 10 minutes on full rate to warm 
up. Then cooking may commence. The Grill is best used on full rate and cooking 
varied by using shelf positions. 

COOKING GUIDE 

 
The centre of the burner plaques are intentionally blank to create an even heat 
distribution. 
 
There are 4 shelf positions for the grill pan, numbered 1-4, No1 being the nearest to 
the burner. This shelf is normally only used for rare cooking and searing the surface 
of meat. 
 
Toast is normally done on the shelf positions 2 or 3 where a better distribution is 
obtained: the time for toast is approximately 1 minute per side. 
 
Parry recommend that the maximum load, in respect of the loading of accessories 
used with the 7072 and 7073 Salamander Grills is a total of 20KG 
 
Operators should take care to systematically check and clean the cooking zone in 
particular the grill pan and receptacles before lighting to avoid the risk of fire. 
It will be found that it takes less time and effort to clean the unit every time it has 
been used, particularly whilst still warm before grease and spillages are burnt on. 
Proprietary cleaners must be used with care 

– they are highly corrosive and may 

cause damage to surfaces and components. The stainless outer panels require a 
wipe down with warm soapy water. 
 
DO NOT USE SCOURING PADS. 
 

MAINTENANCE INSTRUCTIONS 

 

MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY 
REGISTERED FITTERS

 
Parry recommends that this unit is serviced at least every 12 month 

PLEASE NOTE THE LOW RATE ADJUSTER ON THE PILOT HAS BEEN 
FACTORY SET AND SHOULD NOT BE ADJUSTED UNLESS BY A QUALIFIED 
ENGINEER IN WHICH CASE THE LOW RATE ADJUSTER SHOULD BE RE-
SEALED. 

 
Before commencing any maintenance or repair isolate appliance and disconnect 
from gas supply.  
 

Summary of Contents for 7072

Page 1: ...E 1 of 14 www parry co uk INSTRUCTIONS GAS SALAMANDER GRILL MODEL 7072 7073 Customer Information MODEL NUMBER ______________________ SERIAL NUMBER ______________________ PURCHASE DATE ________________...

Page 2: ...NTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS TECHNICAL DETAILS PARTS LIST SPARES LIST WARRANTY INFORMATION MODEL 7072 7073 Gas Salamander Grill The products stated above are designed and built to com...

Page 3: ...will cause burns if touched accidentally Therefore it is the responsibility of the supervisor or equivalent to provide SUITABLE PROTECTIVE CLOTHING for the user Users too should be aware of the regula...

Page 4: ...UST be installed by a competent person in accordance with these and any other relevant regulations Users too should be aware of the regulations governing the use of gas appliances particularly with re...

Page 5: ...ever is operating appliance is fully conversant with its operation and aware of dangers involved in incorrect operation and cleaning especially the danger of burns or scalds from the cooking medium an...

Page 6: ...rills is a total of 20KG Operators should take care to systematically check and clean the cooking zone in particular the grill pan and receptacles before lighting to avoid the risk of fire It will be...

Page 7: ...p to remove thermocouple assemble in reverse To replace ignition electrode Loosen the 2 screws on pilot ignition bracket and withdraw electrode disconnect lead To clean pilot injector Remove the 2 scr...

Page 8: ...reverse order 5 1 LPG to Natural Remove side cover 4 screws Disconnect the gas feed at injector elbow Undo back nut holding back nut to burner Remove existing injector and replace with NAT injector su...

Page 9: ...37mb 14 8 W G 5 43 KW 18527 Btu h G25 25mb 10 W G 5 6 KW 19107 Btu h GAS RATE NATURAL G20 0 5 M HR 17 95 FT HR BUTANE G30 0 397 kg HR 0 875 Lb HR PROPANE G31 0 391 kg HR 0 862 Lb HR G25 25mb 0 62 M HR...

Page 10: ...OPANE G31 37mb 14 8 W G 7 03 KW 24000 Btu h G25 25mb 10 W G 7 22 KW GAS RATE NATURAL G20 0 633 M HR 22 35 FT HR BUTANE G30 0 522 Kg HR 1 149 Lb HR PROPANE G31 0 506 Kg HR 1 113 Lb HR AIR FLOW RATE FOR...

Page 11: ...INSTRUCTION REF IN146 7 DATE 25 02 16 PAGE 11 of 14 www parry co uk EXPLODED VIEW...

Page 12: ...CW nut INJECT119 LPG INJECT193 NAT INJECT135 LPG INJECT220 NAT 15a 8mm Olive OLVCOMPR8 OLVCOMPR8 16 Pilot Assembly PILOT3WAY PILOT3WAY 17 Electrode ELECTRODE ELECTRODE 18 Thermocouple THCP450MM THCP45...

Page 13: ...used in a professional manor following the manufactures instructions and maintenance guide lines The warranty covers defects in the material and component failure only We are not liable for trading lo...

Page 14: ...riddle plates Over use of lava rock on the chargrills recommended use by Parry 2kg only Faulty electrics eg customers plug socket plug wiring junction box fault wrong fuse Any damages caused by the cu...

Reviews: