8
Technical data
Model: HO-1, HO-2
NG (2kPa)
LPG (2.75kPA)
BURNER TYPE
Injector Size
MJ/h
Injector Size
MJ/h
Small auxiliary
0.72
3.36
0.50
3.86
Medium semi-rapid
0.97
5.99
0.65
6.32
Large rapid
1.15
10.08
0.85
9.88
Triple
flame
1.35 13.89 0.97 12.79
Model: HO-3, HO-6
NG (2kPa)
LPG (2.75kPA)
BURNER TYPE
Injector Size
MJ/h
Injector Size
MJ/h
Small auxiliary
0.66**
3.23
0.50*
2.93
Medium semi-rapid
0.97**
5.78
0.65*
5.09
Large rapid
1.18**
9.74
0.80*
8.05
Triple flame
4 x 0.82
1 x 0.75*
18.62
4 x 0.53
1 x 0.47*
13.32
* Injectors flat topped LPG style
** Injectors recessed natural gas style
Triple ring burner on natural gas requires extra primary aeration, hence the change in injector style.
Gas input connection
½” BSP
Electricity supply
AC 220-240v 50/60Hz
Appliance type
A1
Appliance class
class 3 (build in)