CAUTION: This appliance must only be installed and used in rooms with permanent 
ventilation to local standards. 

          

Installation of the appliance and its connection to the electrical mains must only be carried out by 
QUALIFIED PERSONNEL. 
 
Before any procedure, it is important to check that the appliance is disconnected from the power 
supply. The manufacturer declines all responsibility for any damage arising from installation in breach 
of the regulations in force or from failure to comply with accident prevention regulations. 

 

Installation premises 

For proper operation of a gas appliance, the air necessary for the 
combustion of the gas must be able to flow into the room naturally. The air 
must flow into the room directly through openings in the outside walls. 
These openings must have an unobstructed cross-section not less than 
2m

3

/h for each kW of power (see total power in kW on the appliance 

nameplate). 
 
This opening must be constructed so that it will not be obstructed from the 
inside or outside; and placed close to the floor, preferably on the side 
opposite to that on which the flue gases are discharged. If it is not feasible 
to provide these openings in the room where the appliance is installed, the 
necessary air may be taken from an adjacent room, provided that: 
·this room is not a bedroom or a hazardous environment, 
·this room is not in a vacuum, 
·the ventilation between the room where the appliance is installed and the 

adjacent room is guaranteed by permanent openings. 

 
Note that the minimum height from the hob to the kitchen cabinet is 

850mm. 

 

Discharge of flue gases 

Gas cooking appliances must discharge their flue gases through hoods connected directly to flues or 
the outdoors. If it is not possible to install the hood (fig. B), an electric fan must be installed on the 
outside wall or the window of the room, provided it is possible for the ventilation opening to be 
increased in proportion to the delivery rate of the fan (fig. C). For a kitchen, the delivery rate of this 
electric fan must guarantee an hourly air exchange of 3-5 times its volume. In both instances, the use 
of flues already used by other appliances to discharge the flue gases is forbidden. 
 
Please note that the minimum height between the hob and the ventilation system is 750mm. 

Summary of Contents for HO-3-6G-3GW

Page 1: ...n and Operating Instructions W W K Models HO 1 6S 4G HO 1 2S 2G HO 1 6S 3GW HO 1 6W 3GW HO 2 6S 4G HO 2 75S 4GW HO 2 9S 4GW HO 3 6G 3GW HO 3 77G 4GW HO 3 9G 4GW HO 6 6S 3GW HO 6 77S 4GW HO 6 9S 4GW 72...

Page 2: ...te of all detailed technical information and installation instructions It is essential that you only allow a qualified technician to install this appliance to ensure the safety and reliability of this...

Page 3: ...bols ng the instr fety informa ep by step ggestions an ormation co is appliance 73 23 a 89 336 90 396 93 68 and su ance on Techn tallation tec nt types of hen units he instru will help yo ructions ati...

Page 4: ...ondition Otherwise contact your dealer before putting the appliance into operation x The Manufacturer declines all responsibility in the case of failure to comply with accident prevention regulations...

Page 5: ...his manual If you do not find the necessary information contact Parmco Service Department Servicing work on this appliance must be carried out by a qualified technician Always request the use of origi...

Page 6: ...present on versions with lighting integrated in the control knob Dual triple flame version no gas flow maximum gas flow from central burner minimum gas flow from central burner maximum gas flow from o...

Page 7: ...few attempts check that the burner cap and flame cap are correctly positioned To turn off the flame turn the control knob clockwise to the symbol Before removing pans from the burners always lower or...

Page 8: ...er and a little liquid detergent Do not use the following products x household detergents or bleaches x soaped scouring pads not suitable for non stick utensils x steel wool scouring pads x stain remo...

Page 9: ...necessary repairs or adjustments must be carried out with the greatest care and attention For this reason we strongly advise you always to contact the Dealer who sold you the appliance or Parmco Serv...

Page 10: ...E Injector Size MJ h Injector Size MJ h Small auxiliary 0 66 3 23 0 50 2 93 Medium semi rapid 0 97 5 78 0 65 5 09 Large rapid 1 18 9 74 0 80 8 05 Triple flame 4 x 0 82 1 x 0 75 18 62 4 x 0 53 1 x 0 47...

Page 11: ...placed close to the floor preferably on the side opposite to that on which the flue gases are discharged If it is not feasible to provide these openings in the room where the appliance is installed t...

Page 12: ...the end of the gas train Complete with GJ threaded nut fit the gasket between the components as shown in the illustration The gaskets must comply with the local standards Screw the parts together wit...

Page 13: ...liance and the mains with at least 3mm between the contacts of suitable rating for the load and complying with the regulations in force The switch must not break contact in the yellow green earth wire...

Page 14: ...e supply pipeline Setting the minimum level 1 Light the burner as already described 2 Turn the tap to the minimum flame position 3 Remove the control knobs 4 LPG to NG Use a thin blade screwdriver to...

Page 15: ...enly without gaps or overlapping in order to prevent liquid from seeping underneath the hob 1 Remove the pan stands and burners caps and turn the hob upside down taking care not to damage plugs and th...

Page 16: ...g overheating are illustrated on the right The electrical connections of the hob and oven must be made separately both for electrical reasons and for simplifying the removal of the oven through the fr...

Page 17: ...XUFKDVH FDQ EH IRU WKH SURGXFW LWVHOI RU LI LQVWDOOHG ZLWK D NLWFKHQ RU KRXVH WKHQ SURRI RI SXUFKDVH FDQ EH IURP D 3DUPFR UHVHOOHU RI SURGXFWV VXSSOLHG E 3DUPFR Liability under this warranty will not...

Reviews: