background image

 

 

7

Routine maintenance 

Have the condition and efficiency of the gas pipe as well as the pressure regulator (if installed) 
checked periodically. If anomalies are found, do not repair and have the faulty part replaced. 
 
To ensure good performance and safety, the gas regulator taps must be greased periodically. 
 

Periodic lubrication of the taps or malfunctions of the appliance must only be carried out by 
qualified personnel. 

 
 

Service and parts 

Before leaving the factory, this appliance was tested and adjusted by specialist skilled staff to give the 
best operating results. Any subsequent necessary repairs or adjustments must be carried out with 
the greatest care and attention. 
 
For this reason, we strongly advise you always to contact the Dealer who sold you the appliance or 
Parmco Service Department, specifying the nature of the problem, the model of the equipment 
(Mod.), the product number (Prod. No.), and the serial number (Ser. No.). These data are provided in 
the plate on the cover of this manual. Always request the use of original spare parts. 
 

Warranty conditions 

You new appliance is covered by a warranty. The warranty conditions are provided in full in the 
warranty page at the back of this manual. Keep the receipt or delivery note, both of which 
documents your purchase of the appliance and provides proof of date of purchase, in a safe place 
together with the manual.  
 
 

Summary of Contents for HO-1-2S-2G

Page 1: ...Installation and Operating Instructions Models HO 1 2S 2G HO 1 6S 4G HO 1 6S 3GW HO 1 6W 3GW HO 2 6S 4G HO 2 75S 4GW HO 2 9S 4GW HO 6 6S 3GW HO 6 77S 4GW HO 6 9S 4GW HO 7 6G 3GW 727626112013 ...

Page 2: ...ote of all detailed technical information and installation instructions It is essential that you only allow a qualified technician to install this appliance to ensure the safety and reliability of this appliance Furthermore not using appropiate personnel to install this appliance may affect any future warranty claims lodged so please check with Parmco Appliances before any installation is carried ...

Page 3: ... reading t ng symbols ng the instr fety informa ep by step ggestions an ormation co is appliance 73 23 a 89 336 90 396 93 68 and su ance uctions tallation tec nt types of hen units he instru will help yo ructions ation instruction nd Advice oncerning e e complies w and 90 683 6 relating to 6 relating to relating to bsequent a chnician gas ctions ou ns environmen with the foll 3 relating to o Elect...

Page 4: ...therwise contact your dealer before putting the appliance into operation The Manufacturer declines all responsibility in the case of failure to comply with accident prevention regulations Make sure that air is able to circulate freely around the appliance Poor ventilation results in a shortage of oxygen Make sure that the appliance is supplied with the type of gas indicated on the data plate on th...

Page 5: ...ry information contact a service agent or the Parmco s Service Department Servicing work on this appliance must be carried out by a qualified technician only Always request the use of original spare parts Environmental protection advice All the materials used are environmentally compatible and recyclable Please make your contribution to conserving the environment by using the separate waste collec...

Page 6: ... Symbol present on versions with lighting integrated in the control knob Dual triple flame version no gas flow maximum gas flow from central burner minimum gas flow from central burner maximum gas flow from outer and central burners simultaneously minimum gas flow from outer and central burners simultaneously A Burner cap B Lighting plug C Thermocouple D Triple flame cap 1 Hob 2 Auxiliary burner 3...

Page 7: ... attempts check that the burner cap and flame cap are correctly positioned To turn off the flame turn the control knob clockwise to the symbol Before removing pans from the burners always lower or turn off the flame For correct use of the hob For lower gas consumption and better efficiency Use only pans that are stable and fit for use on the burners with dimensions as shown in the table below It i...

Page 8: ...ter and a little liquid detergent Do not use the following products household detergents or bleaches soaped scouring pads not suitable for non stick utensils steel wool scouring pads stain removers for baths or sinks If the hob gets very dirty use specific commercial products Ignition plug Automatic burner ignition is provided when installed by a ceramic plug and a metal electrode B in fig 1 on pa...

Page 9: ...t necessary repairs or adjustments must be carried out with the greatest care and attention For this reason we strongly advise you always to contact the Dealer who sold you the appliance or Parmco Service Department specifying the nature of the problem the model of the equipment Mod the product number Prod No and the serial number Ser No These data are provided in the plate on the cover of this ma...

Page 10: ...x 0 98 HO 1 6S 3GW 1 x 0 50 2 x 0 65 0 1 x 0 98 HO 1 6S 4G 1 x 0 50 2 x 0 65 1 x 0 85 0 HO 2 75S 4GW 1 x 0 50 2 x 0 65 1 x 0 85 1 x 0 98 HO 2 6S 4G 1 x 0 50 2 x 0 65 1 x 0 85 0 HO 2 9S 4GW 1 x 0 50 2 x 0 65 1 x 0 85 1 x 0 98 HO 7 6G 3GW 1 x 0 50 2 x 0 65 0 1 x 0 98 Nominal Gas consumption per burner 3 6 MJ h 6 3 MJ h 10 44 MJ h 13 7 MJ h Universal LPG 2 75kPa Product Code No of burners x Injector ...

Page 11: ...ed close to the floor preferably on the side opposite to that on which the flue gases are discharged If it is not feasible to provide these openings in the room where the appliance is installed the necessary air may be taken from an adjacent room provided that this room is not a bedroom or a hazardous environment this room is not in a vacuum the ventilation between the room where the appliance is ...

Page 12: ...n the end of the gas train Complete with GJ threaded nut fit the gasket between the components as shown in the illustration The gaskets must comply with the local standards Screw the parts together without forcing it fit the union so that it points in the direction required then tighten all parts Connection Make sure the connection to the gas system is using a rigid metal pipe and regulation union...

Page 13: ...appliance and the mains with at least 3mm between the contacts of suitable rating for the load while complying with the regulations in force The switch must not break contact in the yellow green earth wire The brown live wire connected to the L terminal of the terminal board must always be connected to the live wire of the power supply mains In all cases the power supply lead must be positioned so...

Page 14: ...he supply pipeline Setting the minimum level 1 Light the burner as already described 2 Turn the tap to the minimum flame position 3 Remove the control knobs 4 LPG to NG Use a thin blade screwdriver to turn the by pass screw located above the left of the gas valve shaft as shown on the image Gently turn the by pass screw clockwise to the end then turn it anti clockwise 1 2 turn for the triple flame...

Page 15: ...on opening place the special gasket around the bottom edge of the hob It is important to fix this gasket evenly without gaps or overlapping in order to prevent liquid from seeping underneath the hob 1 Remove the pan stands and burners caps and turn the hob upside down taking care not to damage the ignition plugs and the thermocouples 2 Place the gasket around the bottom edge of the hob as shown in...

Page 16: ... methods for avoiding overheating are illustrated on the right The electrical connections of the hob and oven must be made separately both for electrical reasons and for simplifying the removal of the oven through the front of the cabinet The distance must be at least 750mm between the gas hob and the ventilation system and must be at least 850mm between the gas hob and the kitchen cabinet Cutout ...

Page 17: ...SXUFKDVH FDQ EH IRU WKH SURGXFW LWVHOI RU LI LQVWDOOHG ZLWK D NLWFKHQ RU KRXVH WKHQ SURRI RI SXUFKDVH FDQ EH IURP D 3DUPFR UHVHOOHU RI SURGXFWV VXSSOLHG E 3DUPFR Liability under this warranty will not be accepted for HDU DQG WHDU IURP QRUPDO GRPHVWLF XVH DPDJH LQ WUDQVSRUW DPDJH FDXVHG WR WKH SURGXFW E QHJOHFW DEXVH QHJOLJHQFH ZLOIXO DFW RU PLVXVH Q GHIHFW FDXVHG E DFFLGHQW PLVXVH QHJOHFW WDPSHULQ...