Parmco GD-2 Installation And Operating Instructions Manual Download Page 8

 

INSTALLATION OF MOUNTING ASSEMBLY  

READ COMPLETELY BEFORE STARTING  

NOTE: Pay close attention to the order of mount  
assembly parts, as they have been correctly  
assembled by the factory (see 2A). Also reference  
the cushion mount detail in illustration 2D for the  
proper position of the cushion mount (see page 8).  

  

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

Disassemble mount assembly from disposer by turning mount 
ring to the left (counter-clockwise) and remove. 

2.

 

Raise mount ring toward top of sink flange. Remove cushion 
mount. Remove mount ring. You may want to practice installing 
the cushion mount at this point before you are under the sink. 
See paragraph 8.  

3.

 

Unscrew support ring from sink flange and remove fiber gasket.  
You are now left with sink flange and rubber gasket. 

4.

 

The rubber gasket is used instead of plumbers putty with 
stainless steel sinks. Other sinks will require putty.  

5.

 

If no putty is used, insert sink flange through rubber gasket into 
sink opening. Do not rotate sink flange once it is seated.  

6.

 

If you use putty instead of the gasket, form a ring around 
underside of sink flange (see 2C). Insert flange into sink opening, 
press down hard to squeeze out excess putty (see 2B). From 
under sink, trim off excess putty flush with bottom edge of sink 
opening.  

7.

 

From underneath sink, slip fiber gasket onto exposed sink 
flange. With arrows pointing up, screw support ring into the sink 
flange, hand tighten until the sink flange will not move. At this 
point you may want to insert stopper in sink and fill with water 
to check sink flange seal and ensure there are no leaks.  

8.

 

Place mount ring over sink flange and hold in place while 
installing cushion mount (large side down) so the groove on the 
inside of cushion mount fits over lip on sink flange, similar to 
putting the lid on a plastic container (2D).  

9.

 

Cushion Mounting detail:

 When the cushion mount is installed 

correctly, the lip of the sink flange fits into the groove on the 
inside of the cushion mount and mount ring can be pulled 
downward over the cushion mount and will be free to rotate. 
The bottom bead of the cushion mount acts as a gasket 
between the bottom of the sink flange and the top of the 
disposer. See illustration 2D.  

10.

 

The disposer must be installed so that the reset button is readily 
accessible.  

 

RUBBER SINK 
FLANGE GASKET 

CUSHION MOUNT RING 

2C 

2D 

2A

 

2B 

Summary of Contents for GD-2

Page 1: ...Installation and Operating Instructions Models GD 2 GD 3 GD 5 GD 9 727626042016...

Page 2: ...se take special note of all detailed technical information and installation instructions It is essential that you follow these instructions to ensure the safety and reliability of this appliance Furth...

Page 3: ...15 IMPORTANT NOTE It is the law in New Zealand that this appliance must be installed by authorised persons The installation must comply with all the appropriate New Zealand Standards and Regulatory Re...

Page 4: ...ingers or hands into a waste disposer Turn the power switch to the off position before attempting to clear a jam or remove an object from the disposer When attempting to loosen a jam in a waste dispos...

Page 5: ...5 PRODUCT DESCRIPTION RUBBER CUSHION MOUNT RING...

Page 6: ...onditions 4 Before turning disposer off let water and disposer run for approximately 15 seconds after shredding or grinding stops This assures that all waste is thoroughly flushed through the trap and...

Page 7: ...to turn the mount ring tap on one of the extensions from the ring with a hammer Some mounting systems have tubular extensions Inserting a screwdriver into one tube will provide additional leverage fo...

Page 8: ...sink flange see 2C Insert flange into sink opening press down hard to squeeze out excess putty see 2B From under sink trim off excess putty flush with bottom edge of sink opening 7 From underneath sin...

Page 9: ...sition is achieved Hopper projections must be to extreme left of mounting slots see 3C 3D 4 If mount ring is hard to turn you may add a small amount of petroleum jelly or liquid soap to hopper project...

Page 10: ...an result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded DO NOT modify the plug provided with the app...

Page 11: ...11 TYPICAL INSTALLATION...

Page 12: ...chemical drain cleaners into the disposer as they can cause serious corrosion of metal parts If used resulting damage can be easily detected and all warranties are void Mineral deposits from your wat...

Page 13: ...eaker If wiring and electrical components are intact the unit may have internal problems that require service or replacement IF TURNTABLE DOES NOT ROTATE FREELY Turn off disposer Check for any foreign...

Page 14: ...to Improper seating of sink flange gasket centering putty or tightening Support ring not tightened properly Defective or improperly installed cushion mount If unit leaks at the waste elbow leak may b...

Page 15: ...can be from a Parmco reseller of products supplied by Parmco If the products are purchased in a second hand condition from other parties including but not limited to TradeMe Sella etc Liability under...