16 GB
Use of accessories / Maintenance and cleaning
Note!
These may only be used in combination
with a backing plate!
Cup brush, crimped wire
Dimensions:
ø 75 - 100 mm
Speed: min.
12.000
rpm
Cup brush, twisted wire
Dimensions: ø
75
mm
Speed: min.
12.000
rpm
Cup brush, knotted wire
Dimensions: ø
115
mm
Speed: min.
12.000
rpm
Adjusting the disc guard cover
WARNING!
DANGER OF INJURY!
Pull the mains plug out of the mains socket
before you carry out any task on the device.
DANGER OF INJURY!
Always use the an-
gle grinder with the disc guard cover
5
in
place. The disc guard cover must be securely
attached to the angle grinder. To ensure the
highest level of safety while using the device,
ensure that the smallest possible area of the
grinding or cutting tool is exposed to the oper-
ator at all times (see Fig. B, C). The disc guard
cover
5
is there to protect the operator from
pieces breaking off and accidental contact
with the grinding or cutting tool. The disc guard
cover has 5 set positions.
Turn the disc guard cover
5
into the desired
position (working position). The closed side of
the disc guard cover
5
must always be facing
the operator.
Using the auxiliary handle
CAUTION!
For safety reasons this device
must always be used with the auxiliary handle
4
in place. The auxiliary handle
4
can be screwed
on to the left, right or on the top of the head of the
device.
Maintenance and cleaning
WARNING!
DANGER OF INJURY!
Pull the mains plug out of the mains socket
before you carry out any task on the device.
Do not use sharp objects for cleaning
the device. Do not allow any liquids
to enter the device.
Otherwise the tool may
be damaged.
Have the carbon brushes replaced only at the
service centre or an accredited electrical
equipment repair centre. The device requires
no other maintenance.
Clean the device frequently; for best results do
this immediately after you have finished using it.
Use a dry cloth to clean the housing – under
no circumstances use petrol, solvents or clean-
ing agents that attack plastic.
A vacuum cleaner is required to thoroughly
clean the device.
Ventilation openings must always be kept free.
Remove any adhering dust with a narrow paint
brush.