ommend that persons with medical
implants consult their doctor and
the manufacturer of their medical
implant before operating the ma-
chine.
Assembly
Caution! Risk of injury!
- Ensure that you have sufficient
space in which to work, and that
you do not endanger other people.
- All covers and protective devices
must be assembled properly be-
fore commissioning.
- Disconnect the mains plug before
changing the setting on the de-
vice.
Setting up
Place the sharpening station on firm sur
-
face and fasten the device. Ideally, bolt the
drill to the surface. Use the mounting holes
for the work bench assembly (
9) in the
baseplate for this.
The screws and nuts required for as-
sembly are not part of the scope of
delivery.
Mount the sharpener
1. Select one of the three sharpeners.
2. In order to remove a sharpener from
the working position, you must press
down the release lever for the sharp-
ener (
13).
3. Remove the sharpener from the guide
rails, upwards.
4. In the storage positions, the sharpeners
are not fixed to the right and left side
and can be easily removed from the
guide rails.
5. In order to fasten the selected sharpen-
er in the working position, from above
push this into the guide rails. Press
the sharpener down until it snaps into
place.
The sharpeners also present
a safety device. Never use
this device without a sharp-
ener. Risk of injury!
Operation
Caution! Risk of injury!
- Always disconnect the plug from
the mains socket before working.
- Use only grinding disks and ac-
cessories recommended by the
manufacturer. The use of other
insertion tools and other accesso-
ries may cause risk of injury.
- Never operate the device without
the visual protection disk.
- Switch on the equipment only
when it is safely installed on the
work surface.
Despite spark protection,
always wear safety goggles
while working in order to
avoid eye injuries.
We recommend wearing ear pro-
tection to prevent damage to hear-
ing.
Keep your hands away
from the grinding wheel and
grinding belt when the device
is in operation. Injury haz-
ard.
Summary of Contents for PSS 65 C1
Page 3: ...1 5 4 7 8 9 12 10 11 13 13 6 3 2 15 16 14...
Page 4: ...14 15 10 12 11 180...
Page 21: ...21 GR CY LWA 73 5 dB A KWA 3 dB S6 20 10 20 80 S1 II...
Page 22: ...22 GR CY 3 1 A 2...
Page 23: ...23 GR CY 4...
Page 24: ...24 GR CY N 5 RCD Residual Current Device 30 mA...
Page 25: ...25 GR CY A O...
Page 26: ...26 GR CY 9 1 2 13 3 4 5...
Page 28: ...28 GR CY 1 2 6 4 5 3 7 6 4 7 5 6 10 6 10 7 8 10 5 1 2 3 4 10 5 6 7 8 10 1 2 2 3 4 5 10...
Page 29: ...29 GR CY 6 7 8 10 9 10 10 16 10 1 16 2 10 3 10 16 4 60 10...
Page 31: ...31 GR CY 3 16 16 10...
Page 32: ...32 GR CY 3 IAN 374688_2104...
Page 49: ...49...
Page 54: ...54...
Page 55: ...55 Exploded Drawing Explosionszeichnung o informative informativ PSS 65 C1 20210818_rev02_mt...
Page 56: ...56...
Page 57: ...4 10 6 5 7 10...
Page 58: ...10 2...
Page 59: ......