background image

15

GB

IE

NI

Storage

•  Empty the fuel tank with a petrol suc

-

tion pump.

•  Start the engine and allow the engine 

to run until the remaining petrol is used 
up.

•  Change the oil after each season. For 

this, remove the old engine oil from the 
warm engine and replenish with new 
oil.

•  Remove the spark plug. Fill approx. 20 

ml oil into the cylinder with an oil can. 
Pull the start rope slowly so that the oil 
protects the cylinder inside.  

 

Screw the spark plug back in.

•  Store the power generator in a dry, 

well ventilated and dustproof location 
and out of reach of children. 

Disposal / 
Environmental 
protection

•  The power generator, accessories and 

packaging should be properly recyc-
led.

•  Carefully empty the petrol and oil tank 

and take your power generator to a 

recycling plant. The plastic and metal 

parts used on your device can be 
properly sorted according to materials 

and grades and efficiently recycled.

•  Dispose of used oil and petrol residues 

at a disposal site and do not pour into 
sewers or down the drain.

•  Disposal of your sent in defective de

-

vices is carried out free of charge.

Guarantee

Dear Customer,

This equipment is provided with a 3-year 

guarantee from the date of purchase.
In case of defects, you have statutory rights 

against the seller of the product. These 

statutory rights are not restricted by our 
guarantee presented below.

Terms of Guarantee

The term of the guarantee begins on the 

date of purchase. Please retain the original 

receipt. This document is required as proof 

of purchase.
If a material or manufacturing defect occurs 
within three years of the date of purchase 
of this product, we will repair or replace – 
at our choice – the product for you free of 

charge. This guarantee requires the defec

-

tive equipment and proof of purchase to be 
presented within the three-year period with 
a brief written description of what consti-
tutes the defect and when it occurred.
If the defect is covered by our guarantee, you 
will receive either the repaired product or a 
new product. No new guarantee period be-
gins on repair or replacement of the product.

Guarantee Period and Statutory 
Claims for Defects

The guarantee period is not extended by 

the guarantee service. This also applies for 

replaced or repaired parts. Any damages 
and defects already present at the time of 
purchase must be reported immediately af-
ter unpacking. Repairs arising after expiry 
of the guarantee period are chargeable.

Summary of Contents for PS 2900 A1

Page 1: ...GENERATOR PSE 2900 A1 STROMERZEUGUNGSAGGREGAT Originalbetriebsanleitung GENERATOR Translation of the original instructions IAN 315810...

Page 2: ...self with all functions of the device Klappen Sie vor dem Lesen die Seite mit den Abbildungen aus und machen Sie sich anschlie end mit allen Funktionen des Ger tes vertraut GB IE NI Translation of the...

Page 3: ...3 1 2 6 7 4 5 5 21 25 25 23 15 12 15a 3 5 27 28 26 15a 12 23 16 14 13 12 22 24 8 9 10 11 19 20 21 12 25 24 22 18 17 15...

Page 4: ...uaranteed Translation of the original EC declaration of conformity 34 Exploded Drawing 36 Connection to power consuming devices 11 Overload protection 11 Cleaning and Servicing 11 Cleaning 11 Air filt...

Page 5: ...and back foldout pages Delivery Contents Unpack the equipment and check that it is complete Power generator 2 wheels 1 wheel axle with thread M12 2 bases 1 sliding bracket holder 1 sliding bracket 4 s...

Page 6: ...ime opera tion The machine may be operated short term 5 minutes at the output indicated Power generators can only be loaded up to their rated power under the operating conditions indicated If the powe...

Page 7: ...and instructions can cause electrical shock fire and or severe injuries Retain all safety directions and in structions for future use Safety information Power generator 1 The power generator must not...

Page 8: ...ys switch off when trans port or refuelling the engine Make sure that fuel is not spilled onto the engine or exhaust during refuelling Do not refuel or empty the tank near open flames fire or flying s...

Page 9: ...o assemble the power generator Bases 1 Screw the bases 12 onto the bottom of the frame at the points intended for this Use one screw M6x40 22 and one nut M6 24 each for this Wheels 1 First push the wh...

Page 10: ...ller neck Do not fill the tank fully so that the petrol has space to expand 3 Wipe petrol residues off the fuel cap and close the fuel cap again Initial start up Warning Disconnect all elec trical cab...

Page 11: ...7 in the event of an overload Pressing the overload switch 6 al lows the sockets 7 to be put back into operation CAUTION If this occurs reduce the electrical output consumed from the power generator...

Page 12: ...29 with a turning movement 2 Remove the spark plug 30 with the enclosed spark plug spanner 27 Assembly is carried out in reverse order Petrol filter The petrol filter 3 represents a filter cup locate...

Page 13: ...ain screw 10 3 Open the oil tank cap with dip stick 9 4 Open the oil drain screw 10 and drain the old engine oil into a collection container 5 After the old oil has drained out close the oil drain scr...

Page 14: ...ore each use After first 20 hours After 50 hours After 100 hours After 300 hours Visual inspection of power generator Checking the oil level Engine oil change First time Checking the air filter Cleani...

Page 15: ...his equipment is provided with a 3 year guarantee from the date of purchase In case of defects you have statutory rights against the seller of the product These statutory rights are not restricted by...

Page 16: ...the item number on the rating plate Should functional errors or other defects occur please initially contact the service department specified below by telepho ne or by e mail You will then receive fu...

Page 17: ...izzly Tools GmbH Co KG Stockst dter Stra e 20 63762 Gro ostheim Germany www grizzly service eu Replacement parts Accessories Spare parts and accessories can be obtained at www grizzly service eu If yo...

Page 18: ...mechanism responds Check oil level replenish engine oil Spark plug covered in soot Clean or replace spark plug Electrode spacing 0 6 mm No petrol Refill with petrol Defective motor Repair by Service C...

Page 19: ...it Ihres Ger tes ist somit sichergestellt Original EG Konformit ts erkl rung 35 Explosionszeichnung 36 Anschluss stromabnehmender Ger te 26 berlastungsschutz 27 Reinigung und Wartung 27 Reinigung 27 L...

Page 20: ...n Funktionsteile finden Sie auf den Ausklappseiten Lieferumfang Packen Sie das Ger t aus und kontrollieren Sie ob es vollst ndig ist Stromerzeugungsaggregat 2 R der 1 Radachse mit Gewinde M12 2 Standf...

Page 21: ...eistung betrie ben werden Stromerzeugungsaggregate k nnen nur un ter den angegebenen Betriebsbedingungen bis zu deren Nennleistung belastet wer den Wenn das Stromerzeugungsaggregat unter Bedingungen n...

Page 22: ...er Sicherheitshinweise und Anwei sungen k nnen elektrischen Schlag Brand und oder schwere Verletzun gen verursachen Bewahren Sie alle Sicherheitshin weise und Anweisungen f r die Zukunft auf Sicherhei...

Page 23: ...vor elektrischen Gefahren Den Stromerzeugungsaggregat nie mit nassen H nden anfassen Verwenden Sie im Freien nur daf r zugelassene und entsprechend gekennzeichnete Verl ngerungskabel H07RN Bei Verwen...

Page 24: ...in der N he geraucht wird oder in der N he von offenen Flammen Beim Betrieb in gut ventilierten R umen m ssen zus tzliche Ma nahmen zum Schutz vor Feuer und Explosionen ge troffen werden Verwenden Sie...

Page 25: ...0 6 l Maschinen l 15 W 40 ein Verwenden Sie dazu den leinf lltrichter 28 Benzin einf llen Warnung Benzin ist ent flammbar und gesundheits sch dlich Benzin in daf r vorgesehenen Beh l tern aufbewahren...

Page 26: ...n drehen 2 Ein Ausschalter 13 auf Stel lung ON bringen Chokehebel 17 in die linke Position bringen 3 Den Motor mit dem Startseilzug 14 starten hierf r am Griff kr ftig ziehen Sollte der Motor nicht ge...

Page 27: ...ngs und War tungsarbeiten regelm ig durch Dadurch ist eine lange und zuverl ssige Nutzung gew hrleistet Reinigung Das Stromerzeugungsaggre gat darf weder mit Wasser abgespritzt werden noch in Wasser g...

Page 28: ...and pr fen Stellen Sie das Stromerzeugungsag gregat auf ebenen Boden 1 ltankkappe mit Messstab 9 ff nen und ganz aus dem Tank ziehen 2 Zum Kontrollieren des lstands wischen Sie den Messstab mit einem...

Page 29: ...pe Service Zylinderkopf Service Ventilspiel nur bei einem autorisierten Fachbetrieb durchf hren lassen 4 lablassschraube 10 ffnen und altes Motoren l in einen Auffangbeh lter ablassen 5 Nach Auslaufen...

Page 30: ...rantie Sehr geehrte Kundin sehr geehrter Kunde Sie erhalten auf dieses Ger t 3 Jahre Ga rantie ab Kaufdatum Im Falle von M ngeln dieses Produkts stehen Ihnen gegen den Verk ufer des Produkts gesetzlic...

Page 31: ...n Kauf bereit Die Artikelnummer entnehmen Sie bitte dem Typenschild Sollten Funktionsfehler oder sonstige M ngel auftreten kontaktieren Sie zu n chst die nachfolgend benannte Servi ceabteilung telefon...

Page 32: ...nte Service Center Grizzly Tools GmbH Co KG Stockst dter Stra e 20 DE 63762 Gro ostheim Germany www grizzly service eu Ersatzteile Zubeh r Ersatzteile und Zubeh r erhalten Sie unter www grizzly servic...

Page 33: ...gt an lstand pr fen Motor l nachf llen Z ndkerze verru t Z ndkerze reinigen oder tauschen Elektrodenabstand 0 6 mm kein Benzin Benzin nachf llen Motor defekt Reparatur durch Service Center Stromerzeug...

Page 34: ...owing in accordance with the 2000 14 EC emissions guideline Guaranteed sound power level 96 dB A Measured sound power level 90 9 dB A Compliance evaluation process carried out in accordance with Appen...

Page 35: ...entsprechend der Ger uschemissionsrichtlinie 2000 14 EG best tigt Schallleistungspegel Garantiert 96 dB A Gemessen 90 9 dB A Angewendetes Konformit tsbewertungsverfahren entsprechend Anh VI 2000 14 E...

Page 36: ...36 Exploded Drawing Explosionszeichnung PSE 2900 A1 informativ informative 1 2 3...

Page 37: ...37 2019 05 20_rev02_ks...

Page 38: ...15a 11 17 16 10 9 14 18 31 30 29 15 8 7 7 6 22 24 4...

Page 39: ......

Page 40: ...GRIZZLY TOOLS GMBH CO KG Stockst dter Stra e 20 DE 63762 Gro ostheim GERMANY Last Information Update Stand der Informationen 05 2019 Ident No 72037954052019 GB IE NI IAN 315810...

Reviews: