PAFS 550 A1
GB
│
IE
│
13
■
ATTENTION!
►
If you are using a metal container, earth the
paint spray gun
7
beforehand .
♦
Release the trigger
9
as soon as the cleaning
fluid starts flowing out .
♦
Lock the paint spray gun
7
by turning the safety
catch
6
with the tip as far back and up as
possible .
♦
Turn the function switch
e
to the vertical
position (PRIME) .
♦
Unlock the paint spray gun
7
by turning the
safety catch
6
so that its tip is facing down .
♦
Drain off the remaining paint by pulling the
trigger
9
. Hold the paint spray gun
7
over
the detergent container while doing so .
♦
Release the trigger
9
as soon as clear cleaning
fluid starts flowing out .
♦
Lock the paint spray gun
7
by turning the safety
catch
6
with the tip as far back and up as
possible .
♦
Turn the pressure regulator dial
3
to position 0
(off) . Remove the plug from the mains socket .
♦
Depressurise the appliance .
♦
Remove the high-pressure hose
w
from the
paint spray gun
7
with the aid of an adjustable
spanner .
♦
Disassemble the nozzle holder
a
along with
the nozzle
5
, holder
o
and plastic ring
i
(see fig . F) . Clean all parts thoroughly using
suitable cleaning agents .
♦
Lock the paint spray gun
7
by turning the safe-
ty catch
6
with the tip as far back and up as
possible .
NOTE
►
Clean the HEA filters
q
regularly . Replace
them if cleaning is no longer sufficient .
♦
Disconnect the suction hose
2
and the return
hose
1
from the appliance using the hose
clips
l
. Clean the outsides of the hoses .
♦
Remove the filter plate
u
of the intake filter
t
(see fig . E) .
♦
Clean the filter plate
u
thoroughly under
running water .
♦
Remove the high-pressure hose
w
from the
connecting thread
r
using an adjustable
spanner . Counter the connection thread
r
using a second adjustable spanner .
♦
Dip the inlet valve
h
into a container filled with
conservation agent (e .g . fine mechanical oil)
so that the fluid can be sucked up .
♦
Insert the plug into a mains power socket .
♦
Hold a cloth in front of the connecting
thread
r
. Turn the pressure regulator dial
3
to position 1 for about 5 seconds . This helps
to preserve the appliance . Turn the pressure
regulator dial
3
to position 0 (off) .
♦