12
IE
NI
CY
⚠
WARNING!
Risk of injury due to pres-
sure jet! Lock the switch lever every time you
take a break.
3. When taking longer breaks: Move the On/
Off switch (2) to the “
O
” (OFF) position.
Bleeding
Bleeding the supply hose
1. Close the tap.
2. Remove the supply hose from the device.
3. For more, see: Connecting the water supply,
p. 10
Bleeding the device
1. Move the On/Off switch (2) to the “
I
” (ON)
position.
2. Wait until pressure has built up and the mo-
tor stops.
3. Move the On/Off switch (2) to the “
O
”
(OFF) position.
4. Press the switch lever (13) on the pistol grip
(1) until the pressure has been released.
5. Repeat these steps several times until there is
no more air in the device.
Ending operation
1. After working with cleaning agents:
• Empty the cleaning agent tank
• Rinse the device with clear water until the
lines are free of cleaning agent.
2. Release the switch lever (13) on the pistol
grip (1).
3. Move the On/Off switch (2) to the “
O
”
(OFF) position.
4. Close the tap.
5. Press the switch lever on the pistol grip until
the pressure has been released.
6. Unplug the mains plug and wind up the mains
connection cable (9).
7. Disconnect the device from the water supply.
Cleaning and
maintenance
⚠
WARNING!
Electric shock! Protect yourself
when performing maintenance or cleaning work.
Turn off the device. Pull out the mains plug.
You should have any repair and maintenance
work that is not described in these instructions
carried out by our Service Centre. Only use origi-
nal replacement parts.
Cleaning
NOTE!
Risk of damage! Improper cleaning can
damage the device. Never spray down the de-
vice with water. Do not clean the device under
running water. Do not use any abrasive cleaning
agents or solvents.
Always keep the device clean.
Cleaning after operation
1. Move the On/Off switch (2) to the “
O
”
(OFF) position.
2. Pull out the mains plug.
3. Keep the ventilation slits clean and free of ob-
jects.
4. Clean the device with a soft brush or a slight-
ly damp cloth.
Cleaning the standard Vario nozzle
In rare cases, the standard Vario nozzle may be-
come clogged by foreign bodies.
1. Remove the standard Vario nozzle (17).
2. Remove the foreign body from the front using
the nozzle cleaning needle (3).
3. Rinse the standard Vario nozzle with water
from the front to remove the foreign body.
Cleaning the quick connector with filter
insert
1. Remove the quick connector with filter insert
(20) from the device.
Summary of Contents for 351661 2007
Page 20: ...20 GR CY II 90 LWA dB...
Page 21: ...21 GR CY 29 IEC 60364 1 RCD 30 mA...
Page 22: ...22 GR CY 60 mm 2 2 5 mm...
Page 23: ...23 GR CY...
Page 24: ...24 GR CY BA EN 12729 450 1 13 16 28 6 5 4 1 2 11 23 10 3 14 1 4 28 5 RCD 30 mA...
Page 26: ...26 GR CY 2 24 1 1 Vario 1 7 2 8 3 4 5 2 OFF 25 2 60 mm 1 2 2 3 4 5 2 ON 6 7...
Page 28: ...28 GR CY 1 2 OFF 2 3 4 Vario Vario 1 Vario 17 2 3 3 Vario 1 20 2 3 4 1 2 1 1 2 3 4 5 6 5 6...
Page 29: ...29 GR CY 2 1 27 27 24 21 20 31 Vario 17 Vario 17 27 Vario 17 Vario 17 1...
Page 30: ...30 GR CY 3 IAN 351661_2007 e mail...
Page 48: ......
Page 49: ......