PDSS 16 A1
■
22
│
GB
│
IE
Switching on and off
Switching on:
♦
First, press the trigger lock forwards and
then the trigger down to switch the tool on .
Switching off:
♦
Release the trigger .
♦
When you have finished working, disconnect
the tool from the compressed air source .
Maintenance and cleaning
WARNING! RISK OF INJURY!
Disconnect the tool from the
compressed air supply.
CAUTION!
►
Before maintenance, clean off any hazardous
substances that may have accumulated on
the tool (due to working processes) . Avoid
all skin contact with these substances . If the
skin comes into contact with hazardous dusts,
this can lead to severe dermatitis . If dust is
produced or swirled up during maintenance,
it can be inhaled .
NOTE
►
To ensure correct functioning and a long
service life for the tool, pay attention to the
following points:
■
Sufficient and continuous oil lubrication is highly
important for optimum functioning .
■
Check the speed and vibration levels after each
use .
■
Check the idle speed regularly and after any
maintenance is performed:
use a rev counter and perform the measure-
ment without any clamped tools . At a residual
pressure of 6 .3 bar, the idle speed may not be
exceeded under any circumstances .
■
If the tool is exhibiting excessive vibration levels,
the cause of the vibrations must be identified
and repaired .
■
Use only the genuine replacement parts recom-
mended by the manufacturer, otherwise you
could put users at risk . In doubt, contact the
Service Centre .
■
Clean the tool with a soft, dry cloth only .
■
Never use sharp or abrasive cleaning agents
under any circumstances .
Troubleshooting
Fault
Possible
cause
Remedy
Speed too
slow, air
escapes from
the outlet .
Motor parts
jamming due
to dirt .
Check the
pressure sup-
ply filter for
contamination .
Pressure sup-
ply too low .
Check the
pressure sup-
ply filter for
contamination .
Lubricate the
tool as de-
scribed in the
instructions .
If necessary,
repeat the
steps outlined
above .
Tool does
not move;
compressed
air escapes
completely
through the
outlet .
Motor is
jammed due
to material
build-up .
Lubricate the
tool as de-
scribed in the
instructions .
Summary of Contents for 292167
Page 3: ......