background image

JINCHI08 RevC 21/05/14 

Rope-

 Check the rope around the door.  If rope is 

becoming detached, use Hunter Stoves rope glue to 
reattach it.  If the rope is in a poor condition, a 
replacement rope kit may be ordered from the 
Hunter Stoves spares range. 
 

Chimney & Flue Ways-

 It is important that the 

chimney, flue ways and any connecting flue pipe are 
swept regularly.  This means at least once a year for 
smokeless fuels and at least twice a year for wood 
and other fuels.  
  
The baffle will need to be removed from its supports 
in order to sweep the chimney (see ‘Removing 
internal components’ instructions).   
Only wire-centred sweeps’ brushes fitted with a 
guide wheel should be used. 
 
If it is not possible to sweep all parts of the chimney 
through the appliance, ensure there is adequate 
access to cleaning doors. 
 

Periods of Prolonged Non-Use

 - 

If the stove is to be 

left unused for a prolonged period of time then it 
should be given a thorough clean to remove ash 
and unburned fuel residues. To enable a good flow 
of air through the appliance to reduce condensation 
and subsequent damage, leave the air controls fully 
open.

 

If the appliance has been unused for a long period 
of time, such as during the spring and summer 
months, a competent person should check the 
chimney for potential obstructions before lighting 
the stove. 

Gaskets- 

all gaskets used on this appliance are 

produced from a heat resistant material called 
Manniglas. The glass gasket will have to be replaced 
when a new piece of glass is fitted as the gaskets 
become brittle after firing the stove. Over time you  
may find that the gasket changes colour. This is due 
to reduction in the pigment used in the manufacture 
of the product and no cause for concern. 

 

Trouble Shooting

 

 
F

IRE WILL NOT BURN

 

Check that –  
 

 

Chimneys and flue ways are clear. 

 

A suitable fuel is being used. 

 

There is an adequate air supply into the room. 

 

An extractor fan is not fitted in the same room as 
the stove. 

 

Flue draught is above minimum level (see 
installation instructions). 

 

F

IRE BLAZING OUT OF CONTROL

 

Check that –  
 

 

The door is tightly closed. 

 

The air controls are in the closed position. 

 

A suitable fuel is being used. 

 

The glass is not loose. 

 

The door rope seal is in good condition. 

 

Flue draught is below maximum level (see 
installation instructions). 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Summary of Contents for Inset Chevin 8

Page 1: ...JINCHI08 RevC 21 05 14 Inset Chevin 8 Multi Fuel Inset Stove Installation and Operating Instructions ...

Page 2: ...missions Without the permanent bypass in place the appliance is not an exempt appliance and so may leave the householder liable for a fine up to 1000 INSET Chevin 8 Parkray Stoves Trevilla Park Slaugtherbridge Camelford PL32 9TT DSEN 13229 Inset Wood Burning Stove Stove Mass 116 5 kg NOMINAL OUTPUT 6 0 KW CO Emission at 13 O2 0 18 Mean Flue Gas Temperature 326 C EFFICIENCY 75 Flue Gas Mass Flow 6 ...

Page 3: ...ervicing and maintenance of the appliance and chimney system HEALTH AND SAFETY PRECAUTIONS Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met HANDLING Adequate facilities must be available for loading unloading and site handling FIRE CEMENT Some types of fire cement are caustic and should not be allowed to come into contact ...

Page 4: ...ather In a small number of installations occasional local weather conditions e g wind from a particular direction may cause downdraught in the flue and cause the stove to emit fumes In these circumstances the stove should not be used A professional flue installer will be able to advise on solutions to this problem e g anti downdraught cowl CO ALARM Your installer should have fitted a CO alarm in t...

Page 5: ...lue pipe also has adequate clearances to combustible materials The walls surrounding the stove will become hot and should therefore be finished in a heat resistant plaster Do not hang pictures plasma screen televisions or ornaments above the stove as these could be damaged and could potentially create a fire hazard Please check the suitability of any fireplace surround for closed solid fuel applia...

Page 6: ... removed a soot door must be fitted in a suitable position FLUE DRAUGHT If the draught exceeds the recommended maximum a draught stabiliser must be fitted so that the rate of burning can be controlled and to prevent over firing If the reading is less than the recommended minimum then the performance of the appliance will be compromised The flue draught should be checked under fire at high output M...

Page 7: ... fires and therefore not suitable for solid fuel A combustible fire surround with a depth of up to 100mm requires a minimum clearance of 100mm from the side of the stove For combustible fire surrounds with a depth in excess of 100mm this clearance must be increased to 200mm REMOVING INTERNAL COMPONENTS All internal components must be removed prior to fitting the stove This will make handling the s...

Page 8: ...move the lower rear brick support using the finger hole provided to lift it from its slots 7 Cut the cable ties and remove the baffle by rolling it up over the baffle supports and out of the stove 8 Remove the grate bars starting with the high bars 9 Remove the firebox side plates ...

Page 9: ...inkage arm from the front cam bar rotate the cam bar and lift it out 12 Lift out the rear cam bar along with the cam bar linkage arm 13 Lift out the primary air duct 14 Lift out the primary air valve slider 15 Undo the four M6 x 25mm screws and remove the primary air valve and gasket ...

Page 10: ...a stainless steel liner a liner clamp HHN07 ARRT 003 will need to be used The clamp should be connected to the liner by a proprietary flexible liner to single wall flue adaptor using the three fixing holes in the clamp socket and those provided in the flue adaptor The clamp can be attached to the bottom of the liner without the appliance fitted Apply fire cement to the inside of the stove s flue c...

Page 11: ... internal parts by following the removing internal components instructions in reverse order Ensure that the firebox side plates are refitted using the following procedure Insert the side plate so that the front end of it locates under the front plate catch bar as shown Ensure that the back end of the side plate is outside the rear grate support as shown Lower the side plate into position so that t...

Page 12: ...to Combustibles section of the installation instructions WARNING This appliance will be hot when in operation and due care should be taken The supplied operating tool or gloves may be used to open the door and operate the air controls AEROSOLS Do not use an aerosol spray on or near the stove when it is alight AIR CONTROLS Installed operated and maintained correctly this stove will burn cleanly and...

Page 13: ... to be refuelled approximately once every 1 1 hours REDUCED COMBUSTION In order to shut down the stove reduce the primary and secondary air by sliding both controls to the left If the controls are left in this position the fire will be starved of air and will die down If you want to revive the fire it is recommended that the primary air control is opened first and then the secondary air control Wa...

Page 14: ...ations and Local Authority Byelaws this appliance requires regular maintenance of the following N B Refer to the Removing Internal Components section of the installation instructions for details on how to remove each component AS NECESSARY Baffle This should be removed and cleaned at least once a month to prevent any build up of soot or fly ash that could lead to blocked flue ways and dangerous fu...

Page 15: ...duce condensation and subsequent damage leave the air controls fully open If the appliance has been unused for a long period of time such as during the spring and summer months a competent person should check the chimney for potential obstructions before lighting the stove Gaskets all gaskets used on this appliance are produced from a heat resistant material called Manniglas The glass gasket will ...

Page 16: ...it SCPHCE09SDSK Glass Gasket HCE09 030 Glass Clip HHR08 046 Glass Screw FSJM05008SS Door Glass HCE09 031 Rope Sealing Kit SCPHCE09NDSK R H Door HCE09 009 Glass Gasket HCE09 030 Glass Clip HHR08 046 Glass Screw FSJM05008SS Door Glass HCE09 031 Rope Sealing Kit SCPHCE09NDSK Door Handle Assembly AVI08 ARRT 012MB Door Handle Assembly AVI05 ARRT 011MB Single Door HCE09 008 Door Handle AVA08 020MB Door ...

Page 17: ...JINCHI08 RevC 21 05 14 Spares Information Single Door Body Spares ...

Page 18: ...JINCHI08 RevC 21 05 14 Spares Information Double Door Body Spares ...

Reviews: