TECHNICAL DATA
DIMENSIONS
Height
Width
Depth
Height to hotplate
900mm (nominal)
600mm (nominal)
600mm
(to front of
door panel)
Space for fixing at hotplate level
2mm minimum clearance
Space for fixing above hotplate level
Flush-see important note 'Location of Appliance' page 46.
Minimum space above hotplate
787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Weight of appliance
64.5kg.
Minimum distance from rear wall
5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas
Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).
Electric
230V-240V 50 Hz mains 3 core cable is supplied with an integral,
moulded plug fitted with a 3 amp fuse.
GRILL
Natural Gas
L.P.Gas
Heat Input
2.7kW (9215 Btu/h)
2.45kW (176 g/h)
Injector Marking
121
078
HOTPLATE
Natural Gas
R.H.F.
R.H.R.
L.H.R. L.H.F
Heat Input
1.0kW
1.9kW
1.9kW 2.9kW
(3412 Btu/h) (6483 Btu/h) (6483 Btu/h) (9895 Btu/h)
Injector Marking
070
096
096
119
L.P.Gas
R.H.F.
R.H.R.
L.H.R.
L.H.F.
Heat Input
1.0kW
1.9kW
1.9kW
2.9kW
(71.85 g/h)
(136.5 g/h)
(136.5 g/h)
(208.4 g/h)
Injector Marking
050
071
071
083
44
Summary of Contents for SIG 556
Page 1: ...SIG 556 Operating and Installation Instructions...
Page 52: ...52 N O T E S...
Page 53: ...53 N O T E S...
Page 54: ...54 N O T E S SIG 556 311625804...