![Parking Facilities PF6000 Installation, Operation & Maintenance Manual Download Page 10](http://html.mh-extra.com/html/parking-facilities/pf6000/pf6000_installation-operation-and-maintenance-manual_756556010.webp)
in
Parking and access control equipment manufactured in the UK
Automatic Raise Arm Barriers
Pole Arm Adaptor Installation
10
5/6.
7/8.
45 mins
5/6.
Now it is time to fit the pole to the barrier, you must drill through the pole
AFTER
you have slid it onto
arm using a 6mm HSS drill bit. The holes should be drilled at 60mm then 200mm from the knuckle as
shown above. These measurements have been supplied to maintain the optimum strength of the pole arm
adaptor. Also please note that the pole is a precise fit so may need a degree of manipulating onto the
7/8.
When all holes have been drilled use the M6 bolts supplied to secure the pole to the adaptor, if you
have any accessories such as a mag lock or boom lights connect these before securing the pole. Once
this is done manually wind the pole up and down to check operation and alignment.Now connect all loops,
power and access control using the wiring diagram. For any other specific wiring access control wiring
details please contact your supplier. Just remember to check all connections and the barrier is earthed
60 5
10
15
20
25
30
35
40
45
50
55
Pictured above is a domed pole arm adaptor the indicators show
were you should drill the 6mm holes using a standard 6mm drill
bit, drill all the way through from one side to the other.
Drill holes here
Pre-cut out point
60mm
Picture shown is without pole for illustration purposes
Pictured above is a domed pole arm adaptor the indicators show
were you should drill the 6mm holes using a standard 6mm drill
bit, drill all the way through from one side to the other.
Drill holes here
Pre-cut out point
200mm
60mm
Picture shown is without pole for illustration purposes
Picture shown is now with a pole
Pictured above is a the pole arm adaptor(left) now covered with
a pole (this can be varying lengths) you need to now use the M6
bolts supplied to attach the pole arm.
Drill through the pole arm
in the same place as before
Note! YOU CAN DRILL THROUGH BOTH THE
POLE ARM AND THE ADAPTOR AT THE SAME TIME
Domed Oval Pole
Arm Adaptor
Domed Round Pole
Arm Adaptor
Flat Round Pole
Arm Adaptor
HD Round Pole
Arm Adaptor