background image

WARNING:

•  Use only with approved refrigerants. Review 

product specifications for more details.

•  Periodically check to ensure the ZoomLock jaws are 

meeting and aligned.

•  Wear proper eye protection during installation.

•  Keep hands and fingers away from the jaws during 

use.

•  Use supplied brush to ensure ZoomLock jaws are 

debris free.

•  Do not leave battery on charger unattended or 

overnight.

•  Do not braze or solder within 5 inches of a Zoom-

Lock fitting. If brazing or soldering nearby, appro-

priate heat sink or wet rag steps must be taken.

STEP 8

Use the supplied deburring tool to remove any 

residual burrs from the outside and inside of the 

copper tube (sharp edges may damage the o-ring).

STEP 7

The ZoomLock Crimp Gauge can ensure the tube end 

is perpendicular.

STEP 6

Cut the copper tube using the supplied tube cutter.

STEP 4

Slide charged battery into base of 

Crimping Tool.

 > CL

ICK <

 >

 CLIC

<

 1

 2

STEP 2

Press the locking pin, then rotate 45° to release.

 1

 2

SD-404 / 52015

Parker Hannifin Corporation

Sporlan Division

206 Lange Drive • Washington, MO 63090 USA

phone 636 239 1111 • fax 636 239 9130

www.sporlanonline.com/zoom

WARNING – USER RESPONSIBILITY

Failure or improper selection or improper use of the products described herein or related items 

can cause death, personal injury and property damage.

This document and other information from Parker Hannifin Corporation, its subsidiaries and 

authorized distributors provide product or system options for further investigation by users having 

technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of 

the system and components and assuring that all performance, endurance, maintenance, safety and 

warning requirements of the application are met. The user must analyze all aspects of the application, 

follow applicable industry standards, and follow the information concerning the product in the current 

product catalog and in any other materials provided from Parker or its subsidiaries or authorized 

distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system 

options based upon data or specifications provided by the user, the user is responsible for 

determining that such data and specifications are suitable and sufficient for all applications and 

reasonably foreseeable uses of the components or systems.
For safety information see the Safety Guide at www.parker.com/safety or call 1-800-CParker.

OFFER OF SALE

The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its 

subsidiaries or its authorized distributors. This offer and its acceptance are governed by the 

provisions stated in the detailed “Offer of Sale” available at www.parker.com.

FOR USE ON AIR CONDITIONING and REFRIGERATION SYSTEMS ONLY.

© 2015 Parker Hannifin Corporation.

STEP 3

Slide jaws over Crimping Tool head, then depress 

locking pin until it clicks.

STEP 5

Press and hold the trigger 

on Crimping Tool to 

calibrate.

Calibration is 

recommended daily, 

prior to use.

STEP 1

Slide battery into 

charger. Plug 

charger into a power 

source. Check to see 

that the charging 

light is on. When red 

light turns off and 

green light turns on, 

battery is fully 

charged ~ 20 

minutes.

*Jaw quantity and sizes differ per Kit Item Number.    

WHAT’S IN THE BOX >

 

< INSTALLATION

   AIDS NEEDED

X2

*

It’s easy to install ZoomLock fittings for a clean, 

secure, braze-free connection, but be sure to 

read and follow the instructions enclosed.
Contact Parker’s technical support team at 

636-392-3906 if you have questions regarding 

ZoomLock applications.

IMAGE LIFE WITHOUT BRAZING.

BRAZE-FREE FITTING

INSTALLATION