WARNING:
• Use only with approved refrigerants. Review
product specifications for more details.
• Periodically check to ensure the ZoomLock jaws are
meeting and aligned.
• Wear proper eye protection during installation.
• Keep hands and fingers away from the jaws during
use.
• Use supplied brush to ensure ZoomLock jaws are
debris free.
• Do not leave battery on charger unattended or
overnight.
• Do not braze or solder within 5 inches of a Zoom-
Lock fitting. If brazing or soldering nearby, appro-
priate heat sink or wet rag steps must be taken.
STEP 8
Use the supplied deburring tool to remove any
residual burrs from the outside and inside of the
copper tube (sharp edges may damage the o-ring).
STEP 7
The ZoomLock Crimp Gauge can ensure the tube end
is perpendicular.
STEP 6
Cut the copper tube using the supplied tube cutter.
STEP 4
Slide charged battery into base of
Crimping Tool.
> CL
ICK <
>
CLIC
K
<
1
2
STEP 2
Press the locking pin, then rotate 45° to release.
1
2
SD-404 / 52015
Parker Hannifin Corporation
Sporlan Division
206 Lange Drive • Washington, MO 63090 USA
phone 636 239 1111 • fax 636 239 9130
www.sporlanonline.com/zoom
⚠
WARNING – USER RESPONSIBILITY
Failure or improper selection or improper use of the products described herein or related items
can cause death, personal injury and property damage.
This document and other information from Parker Hannifin Corporation, its subsidiaries and
authorized distributors provide product or system options for further investigation by users having
technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of
the system and components and assuring that all performance, endurance, maintenance, safety and
warning requirements of the application are met. The user must analyze all aspects of the application,
follow applicable industry standards, and follow the information concerning the product in the current
product catalog and in any other materials provided from Parker or its subsidiaries or authorized
distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system
options based upon data or specifications provided by the user, the user is responsible for
determining that such data and specifications are suitable and sufficient for all applications and
reasonably foreseeable uses of the components or systems.
For safety information see the Safety Guide at www.parker.com/safety or call 1-800-CParker.
OFFER OF SALE
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its
subsidiaries or its authorized distributors. This offer and its acceptance are governed by the
provisions stated in the detailed “Offer of Sale” available at www.parker.com.
FOR USE ON AIR CONDITIONING and REFRIGERATION SYSTEMS ONLY.
© 2015 Parker Hannifin Corporation.
STEP 3
Slide jaws over Crimping Tool head, then depress
locking pin until it clicks.
STEP 5
Press and hold the trigger
on Crimping Tool to
calibrate.
Calibration is
recommended daily,
prior to use.
STEP 1
Slide battery into
charger. Plug
charger into a power
source. Check to see
that the charging
light is on. When red
light turns off and
green light turns on,
battery is fully
charged ~ 20
minutes.
*Jaw quantity and sizes differ per Kit Item Number.
WHAT’S IN THE BOX >
< INSTALLATION
AIDS NEEDED
X2
*
It’s easy to install ZoomLock fittings for a clean,
secure, braze-free connection, but be sure to
read and follow the instructions enclosed.
Contact Parker’s technical support team at
636-392-3906 if you have questions regarding
ZoomLock applications.
IMAGE LIFE WITHOUT BRAZING.
BRAZE-FREE FITTING
INSTALLATION