VF814

67

68

65

14

1

2

8

5

8

3

24¾

26¾

39

2

13

10

3

8

-

-

225

5

VF829

133

136

130

29

1

2

8

5

8

3

39

41

1

8

68

2

13

10

3

8

-

-

265

8

VF844

200

204

195

44

1

2

8

5

8

3

57

1

16

59

7

16

101

2

13

10

3

8

-

-

305

11

VF1614

267

272

260

14

4

1

16

15

37

13

16

40

13

16

52

4

24¼

9

7

5

8

7

5

8

18

7

16

500

22

VF1629

533

544

520

29

4

1

16

15

52

13

16

55

13

16

82

4

24¼

9

7

5

8

7

5

8

18

7

16

560

35

VF1644

800

816

780

44

4

1

16

15

66¾

69¾

110

4

24¼

9

7

5

8

7

5

8

18

7

16

620

48

VF2029

800

816

780

29

6

1

20

19½

60

1

8

65

5

8

89

6

28

13

26

1000

67

VF2044

1200 1224 1170

44

6

1

20

19½

74

5

8

80

7

16

118

6

28

13

26

1100

88

VF2829

1600 1632 1560

29

12

1

28

24

48½

64¼

77

8

36

18

9

9

35

1500

125

VF2844

2400 2448 2340

44

12

1

28

24

64

3

8

79¾

108

8

36

18

9

9

35

1600

165

VF3644

3600 3672 3510

44

18

1

36

5

8

26

63

3

8

84

109

10

48

23

12½

12½

44

2250

288

VF4244

5400 5508 5265

44

27

1

42¾

28

66

87

3

8

110

12

54

28

13

13

52¼

3800

400

1. 

Flow rates are for FO-614PLF series pleated paper cartridges.  For higher viscosity fluids, consult your Velcon Representative.

2. 

 VF Series Filters are designed to accommodate our standard 6 in. O.D., 31/2 in. I.D., 141/2 in. long cartridges that are stacked one, two, or three 
high. Many cartridges are available in longer lengths that eliminate stacking. For example, a 44 inch long FO-644PLF1M could be used in place of 
three 141/2 inch long cartridges. This makes for easier and less expensive changeouts.

3. 

A number of threaded base filter cartridges (e.g. FO-644PLF5TB) are available, which allow for easier cartridge changeout and removal of 
particulate matter from the deckplates. See data sheet #1549. The threaded base cartridges mount on the 6000T Adapters.

4. 

 Dimensions shown are for estimating purposes only. For exact dimensions, obtain certified drawing.

5. 

 VF16 and VF20 Series vessels have flat covers. VF16 Series vessels do not have hydraulic lift jacks.

6. 

Available Aquacon® Cartridges are AC-6xx05 and AD-6xx25 where xx represents cartridge lengths of 14, 29, and 44 inches.

Figure 1

Figure 2

Summary of Contents for Velcon HF Series

Page 1: ...ril 2014 Standard Filter Vessel Installation and Operation Manual VF HF Parker Hannifin Corporation Velcon Filtration Division 1210 Garden of the Gods Road Colorado Springs CO 80907 1 719 531 5855 Phone 1 719 531 5690 Fax www velcon com vfsales parker com ...

Page 2: ...ilter Vessel Installation Operation Manual VEL2199 0414 WARNING DO NOT PRESSURE TEST THIS VESSEL WITH AIR PRESSURE TESTING WITH AIR IS A HAZARDOUS PROCEDURE THIS VESSEL IS TO BE PRESSURIZED ONLY WITH THE LIQUID FOR WHICH IT IS INTENDED TO BE USED AND ONLY TO THE MAXIMUM DESIGN PRESSURE SHOWN ON THE VESSEL NAME PLATE ...

Page 3: ...losures 11 Installing Tie Rods 12 Appendix A Pleated Media Filter Cartridges 16 17 B F0 6xxA3 FOH 6xxA1 EI1590 Qualified Filter Cartriges 18 19 C VF Series Vertical Filter Vessels 20 21 D Assembly Torque Recommendations 22 23 DISCLAIMER This generic vessel manual is provided for your information with the understanding that each vessel sent out from Velcon is customized for the particular vessel an...

Page 4: ...4 Parker Hannifin Corporation Velcon Filtration Division Colorado Springs CO 80907 USA Velcon Filtration Division Filter Vessel Installation Operation Manual VEL2199 0414 ...

Page 5: ...D COVER TO ENSURE STABILITY OF THE FILTER 3 Bolt the filter to a stable base 4 Carefully install correct gaskets on the inlet and outlet connections and connect to the inlet and outlet piping 5 Connect any accessories that are not already installed See Accessory Parts List and literature as required 6 Cartridges are normally packed separately Open the vessel cover and install cartridges as explain...

Page 6: ...B Turn the handle the other way 90 or 180 depending on the type of valve and record the pressure reading C Subtract the lower reading from the higher reading to determine differential pressure The higher reading is inlet pressure If the filter separator is equipped with a pressure gauge and a selector valve use the following procedure for determining differential pressure A Turn the handle one way...

Page 7: ...ighten nuts on tie rods until the rubber wash ers begin to curl Do not over torque K Check the cover gasket for alignment re place the cover and secure tightly The Filter is now ready for the start up procedure SUMP CHECKS NOTE USE ONLY PARKER VELCON CARTRIDGES IN THIS FILTER VELCON CANNOT WARRANT PERFORMANCE IF ANY OTHER MANUFACTURER S CARTRIDGES ARE USED To reorder cartridges and replacement par...

Page 8: ...8 Parker Hannifin Corporation Velcon Filtration Division Colorado Springs CO 80907 USA Velcon Filtration Division Filter Vessel Installation Operation Manual VEL2199 0414 ...

Page 9: ...9 Parker Hannifin Corporation Velcon Filtration Division Colorado Springs CO 80907 USA Velcon Filtration Division Filter Vessel Installation Operation Manual VEL2199 0414 Installation Instructions ...

Page 10: ...der to the threaded clips on the vessel walls using the nut and lockwasher Adjust the spider clip nuts so the spider lies flat on the ends of the cartridges Install the washer and nut over the ends of the cartridges to affix the spider to the cartridge ends Snug the nuts DO NOT TIGHTEN YET Adjust the ends of each cartridge to create even separation between the cartridges and between the cartridge ...

Page 11: ...Table One lists guideline torque values for lubricated bolts for common sizes used for vessel closures Always use lubricated bolts as this reduces the required torque improves torque accuracy and retards corrosion A common cause of inaccurate bolt torque is inappropriate bolt torquing procedures Key elements to the procedure are application of the torque in stages and in a specific cross torquing ...

Page 12: ...op or end of the cartridge or cartridge stack with the tie rod ex tending out from the end seal plate tie rod hole 8 Adjust the tie rod by screwing it in or out until the amount extending beyond the end cap is 1 5 8 Remove the cartridges spacers and caps 9 Screw the nut at the end of the tie rod down against the mounting adapter while preventing the tie rod from turning 10 Tighten the nut to 5 foo...

Page 13: ... screw the short end of the tie rod into the tie rod bar on the vessel Screw in about one inch 5 Install a separator over the tie rod and into place on the mounting adapter so the tie rod extends from the end seal cap tie rod hole 6 On double open ended separators place an end seal plate on the top or end of the separator with the tie rod extending out from the end seal plate tie rod hole 7 Adjust...

Page 14: ...14 Parker Hannifin Corporation Velcon Filtration Division Colorado Springs CO 80907 USA Velcon Filtration Division Filter Vessel Installation Operation Manual VEL2199 0414 ...

Page 15: ...15 Parker Hannifin Corporation Velcon Filtration Division Colorado Springs CO 80907 USA Velcon Filtration Division Filter Vessel Installation Operation Manual VEL2199 0414 Appendix Accessories ...

Page 16: ... from most industrial fluids Corrugated Media Prevents pleat pinch off assuring all filtration media is utilized Buna N Gaskets The best general gasket material available assures positive seal in most fluids Thermoset Bonding Material Durable endcap to media bond prevents internal bypassing Threaded base filter elements Available for easier installation SPECIFICATIONS 75 psi Collapse strength 5 9 ...

Page 17: ...644PLF5M 5 Yes FO 644PLF10M 10 Yes FO 644PLF15M 15 Yes FO 644PLF25M 25 Yes Model Dim Nominal Micron Rating Protec tive Outer Wrap FO 644PLF1 4TB 6 x 44 Threaded Base Yes FO 644PLF1 2TB Yes FO 644PLF1TB 1 Yes FO 644PLF2TB 2 Yes FO 644PLF5TB 5 Yes FO 644PLF10TB 10 Yes FO 644PLF25TB 25 Yes FO 656PLF1M 6 x 56 x 3 ID 1 Yes FO 656PLF1 2TB 6 x 56 Threaded Base Yes FO 656PLF1TB 1 Yes FO 656PLF2TB 2 Yes FO...

Page 18: ...ations and Qualification Procedures for Aviation Fuel Microfilters Product Features Large Surface Area Allows high flow rate with low initial pressure drop and maximum contaminant holding capacity Resin Impregnated Microfiberglass Cellulose Media Maintains strength resists effects of water and heat 75 psi Collapse Strength Heavy gauge carbon steel endcaps and center tube give safety margin against...

Page 19: ... 614A3TB 6 x 141 2 x 31 2 ID NO 3 47 FO 629A3 6 x 29 x 31 2 ID YES 3 111 FO 629A3TB 6 x 29 x 31 2 ID YES 3 105 FO 644A3 6 x 44 x 31 2 ID YES 3 171 FO 644A3TB 6 x 44 x 31 2 ID YES 3 165 FO 656A3 6 x 56 x 31 2 ID YES 3 219 FO 656A3TB 6 x 56 x 31 2 ID YES 3 213 FOH 614A1K 6 x 141 2 x 31 2 ID YES 1 53 FOH 614A1TB 6 x 141 2 x 31 2 ID YES 1 47 FOH 629A1K 6 x 29 x 31 2 ID YES 1 111 FOH 629A1TB 6 x 29 x 3...

Page 20: ...onratingand typeofcartridgethatisrightforyour application PLFSeries pleatedsur facetypefiltration FGSeries fi berglassdepthtypefiltration or Aquacon Series dehydrationand filtration Filter vessels VF814 through VF844 such as the VF814150 shown at right have through bolt covers NPT connections and include fittings for drain pressure gauge and air vent VF1614 and larger vessels such as the VF2044150...

Page 21: ...9 35 1600 165 VF3644 3600 3672 3510 44 18 1 365 8 26 633 8 84 109 10 48 23 12 12 44 2250 288 VF4244 5400 5508 5265 44 27 1 42 28 66 873 8 110 12 54 28 13 13 52 3800 400 1 Flow rates are for FO 614PLF series pleated paper cartridges For higher viscosity fluids consult your Velcon Representative 2 VF Series Filters are designed to accommodate our standard 6 in O D 31 2 in I D 141 2 in long cartridge...

Page 22: ...22 Parker Hannifin Corporation Velcon Filtration Division Colorado Springs CO 80907 USA Velcon Filtration Division Filter Vessel Installation Operation Manual VEL2199 0414 NOTES ...

Page 23: ...23 Parker Hannifin Corporation Velcon Filtration Division Colorado Springs CO 80907 USA Velcon Filtration Division Filter Vessel Installation Operation Manual VEL2199 0414 NOTES ...

Page 24: ...49 0 711 7071 290 10 www parker com rfde Hydraulic Filtration Hydraulic Filter Arnhem Holland 31 26 3760376 www parker com hfde Urjala Operation Urjala Finland 358 20 753 2500 www parker com hfde Condition Monitoring Centre Norfolk England 44 0 1842 763 299 www parker com hfde Parker Kittiwake West Sussex England 44 0 1903 731 470 www kittiwake com Parker Procal Peterborough England 44 0 1733 232 ...

Reviews: