GENERAL SAFETY INFORMATION

 

A filter housing is potentially hazardous if used improperly, and without complying with the instructions included 
in  this  document.    This  document  describes  permissible  uses,  applicable  safety  regulations  and  prescribes 
training for maintenance personnel – refer to Table 2. 

 

 

Do  not  perform  unauthorised  modifications  or  repairs;  Parker  is  not  liable  for  any 
modifications undertaken by end users. 

 

Do not operate outside of the pressure and temperature rating – refer to section 4.  

 

Do not install in an active seismic zone or where weather may impart additional loads. 

 

Do not use in an ATEX designated zone, unless the filter housing is rated to do so with 

the  appropriate  control  measures  implemented  that  conform  to  the  governing 
regulations, directives and standards in the country of use. 

 

Do  not  use  with  fluids  and/or  under  conditions  that  are  different  to  the  design 
specification. 

 

Do use in a manner that is deemed contrary to specific national or regional regulations. 

 

Do  not  use  spare parts that are  not  specific  to  the  model  or  type  of  filter housing 
installed. 

 

 

Compliance to National  and local  codes  of  practice,  environmental regulations  and 
Health & Safety directives have precedence over this guidance.

1

 

 

Installation,  operation  and  maintenance  should  only  be  performed  by  competent 
personnel using appropriate risk assessment methodology. 

 

Read  and  understand  any  documentation  provided  for  the  accessories  and comply 
with the instructions for use. 

 

Suitable protective systems should be fitted to prevent out of control events.  

 

Filter housings must be supported to connecting pipework, as they are not designed 

to sustain load, vibration or cyclic loading.  

 

The filter housing should be maintained and inspected regularly to ensure it meets the 
design specification during its service life. 

 

 

If the filter housing shows signs of damage it must not be placed into service. 

 

Residual process fluid  in  the filter  housing  or on used  filters  cartidges  may  lead  to 
injury or death. 

 

Rapid depressurisation may lead to injury or death. 

 

Poorly installed, operated  and maintained pressure equipment may lead to injury or 
death. 

Table 2 

 

 

 

                                                                 

 

1

 Directive 2014/68/EU relating to the making available on the market of pressure equipment 

Summary of Contents for VBA-11A

Page 1: ...179550500 Rev 2 Instructions for Use VBA Range...

Page 2: ...al Layout 6 4 3 Spare Parts 7 4 4 Data Label 7 4 5 Declaration of Conformity 7 5 INSTALLATION 8 5 1 Receiving and Handling 8 5 2 Storage 8 5 3 Installation Location 8 5 4 Connection and Assembly 9 6 O...

Page 3: ...authorized distributors provide product or system options for further investigation by users having technical expertise The user through its own analysis and testing is solely responsible for making...

Page 4: ...p to the coupling point connecting it to other equipment a vessel may be composed of more than one chamber Filter Cartridge Filter element installed inside the housing with a sealing feature PED Press...

Page 5: ...se spare parts that are not specific to the model or type of filter housing installed Compliance to National and local codes of practice environmental regulations and Health Safety directives have pre...

Page 6: ...ury or death Table 3 4 1 Product Description Refer to the Parker general arrangement drawing number 179503030 for details of the filter housing further information can be found in the product specific...

Page 7: ...d to the main filter housing body to provide important information about the specification see Figure 2 Pos Description 1 Parker Part Code 2 Design Temperature C 3 Design Pressure Bar 4 PED Fluid Grou...

Page 8: ...t of the product inform the supplier immediately of any damage and await instructions whether to proceed b It is recommended to unpack the filter housing near to final installation location to avoid u...

Page 9: ...all drain valves and discharges points to prevent fluid from harming personnel property or the local environment 6 Operation and Maintenance Please read and understand this document before operating o...

Page 10: ...ep 2 For disposal of the used filter cartridge refer to section Decommissioning and Disposal d Fit the replacement filter cartridge in accordance with the instructions provided in the filter cartridge...

Page 11: ...ondition which could lead to the onset of a hazardous situation d Replace worn parts with those designed for the filter housing Check the condition of filter housing seals each time the cartidges are...

Page 12: ...eases to work properly Replace closure locking ring or housing contact your local Parker representative Leakage of fluids from access connections to the tank Inadequately tightened connections Contami...

Page 13: ...0500 Rev 2 Page 13 of 13 www parker com bioscience Parker Hannifin Manufacturing Ltd Bioscience Filtration EMEA Durham Road Co Durham DH3 2SF England phone 44 0 191 4105121 email bioscience emea parke...

Reviews: