Start Up and Operation 

a)

 

Ensure that the filter housing, accessories and connections are sealed before operation. 

b)

 

Ensure the drain valves and isolation valves are closed, if applicable, before operation. 

c)

 

Turn on the supply and partially open the inlet isolation valve to allow the housing to pressurise. 

d)

 

Inspect for leaks and remedy. 

e)

 

Fully open the inlet isolation valve.  

f)

 

Partially open the downstream isolation valve to start flow.  

g)

 

Inspect for leaks and remedy. 

h)

 

Fully open the outlet isolation valve.  

 

6.3

 

Housing Maintenance 

a)

 

Always be vigilant of pressures, temperatures and redisual process fluid when performing maintenance 
on the filter housing. 

b)

 

Always isolate the filter housing from the process, depressurize and drain process fluids before opening. 

c)

 

Frequently  inspect  the  condition  of  pressurised  parts,  accessories  and  connections  for  corrosion, 

abrasions, deformation due to blows, breakage or any other abnormal condition which could lead to 
the onset of a hazardous situation.   

d)

 

Replace worn parts with those designed for the filter housing.  Check the condition of filter housing 

seals each time the cartidges are replaced; replace if damaged.  It is recommended that the seals are 

replaced annually except for PTFE and/or FEP seals that should be replaced each time the filter housing 
is opened. 
 

7

 

 

Decommissioning and Disposal 

Table 7 contains guidelines for safe disposal of materials; local laws take precedence.  

What  

Materials 

Disposal Route 

Filter housing packaging  

Filter packaging 

Wood, cardboard, plastic 

film 

and 

packaging 

supports 

Wood – widely recyclable 

Cardboard - widely recyclable 
Plastic  film  –  potentially  recyclable  (check 
locally) 
Packaging  supports  -  potentially  recyclable 

(check locally) 
Avoid  landfill,  where  possible,  and  use 
incineration to energy schemes.  

Consumables 

and 

filter 

cartridges 

Elastomers,  polyolefins, 

thermoplastics 
(potentially 
contamination) 

Non-hazardous  waste  -  avoid  landfill,  where 

possible,  and  use  incineration  to  energy 
schemes. 
Hazardous waste – follow local regulations. 

Filter Housing 

Stainless steel 

Recyclable  after  decontamination  (check 

locally). 

Table 7 

 

 

 

 

 

 

Summary of Contents for VBA-11A

Page 1: ...179550500 Rev 2 Instructions for Use VBA Range...

Page 2: ...al Layout 6 4 3 Spare Parts 7 4 4 Data Label 7 4 5 Declaration of Conformity 7 5 INSTALLATION 8 5 1 Receiving and Handling 8 5 2 Storage 8 5 3 Installation Location 8 5 4 Connection and Assembly 9 6 O...

Page 3: ...authorized distributors provide product or system options for further investigation by users having technical expertise The user through its own analysis and testing is solely responsible for making...

Page 4: ...p to the coupling point connecting it to other equipment a vessel may be composed of more than one chamber Filter Cartridge Filter element installed inside the housing with a sealing feature PED Press...

Page 5: ...se spare parts that are not specific to the model or type of filter housing installed Compliance to National and local codes of practice environmental regulations and Health Safety directives have pre...

Page 6: ...ury or death Table 3 4 1 Product Description Refer to the Parker general arrangement drawing number 179503030 for details of the filter housing further information can be found in the product specific...

Page 7: ...d to the main filter housing body to provide important information about the specification see Figure 2 Pos Description 1 Parker Part Code 2 Design Temperature C 3 Design Pressure Bar 4 PED Fluid Grou...

Page 8: ...t of the product inform the supplier immediately of any damage and await instructions whether to proceed b It is recommended to unpack the filter housing near to final installation location to avoid u...

Page 9: ...all drain valves and discharges points to prevent fluid from harming personnel property or the local environment 6 Operation and Maintenance Please read and understand this document before operating o...

Page 10: ...ep 2 For disposal of the used filter cartridge refer to section Decommissioning and Disposal d Fit the replacement filter cartridge in accordance with the instructions provided in the filter cartridge...

Page 11: ...ondition which could lead to the onset of a hazardous situation d Replace worn parts with those designed for the filter housing Check the condition of filter housing seals each time the cartidges are...

Page 12: ...eases to work properly Replace closure locking ring or housing contact your local Parker representative Leakage of fluids from access connections to the tank Inadequately tightened connections Contami...

Page 13: ...0500 Rev 2 Page 13 of 13 www parker com bioscience Parker Hannifin Manufacturing Ltd Bioscience Filtration EMEA Durham Road Co Durham DH3 2SF England phone 44 0 191 4105121 email bioscience emea parke...

Reviews: