Hydraulic Motor/Pump
Series V14
EO/EP/HO/HP control description
Basically, the controls function in a similar
way. At increasing solenoid current (EP) or
increasing pilot pressure (HP) the control
moves towards the min displacement posi-
tion. At decreasing current/pilot pressure, the
control retracts towards max displacement.
In comparison with EP and HP, the EO and
HO controls have no modulating spring or
feedback arm; this means that only min and
max displacements (but no intermediate
positions) are available with these controls.
Module cross section
(EP shown)
1.
Two-part seal
2.
Control module housing
3.
Treshold adjustment screw
4.
Feedback arm (EP, HP only)
5.
Treshold spring
6.
Modulating spring (EP, HP only)
7.
Servo valve spool
8.
Solenoid (EO, EP only);
cover on HO, HP
9.
End cover (max displ. limit)
10. Max displ. limiting screw/bushing
11. Setting piston
12. Connecting arm
13. Set screws
14. Min displ. limiting screw/bushing
15. Setting piston position sensor
(EP, EO option)
16. End cover (min displ. limit)
E.
Restrictor location, servo supply
12345678
910
11
12
13
14
15
16
E
2
4
5
1
3
6
7
8
E
9
10
11
12
13
14
15
16
13