![Parker UC-DF Quick Start Manual Download Page 5](http://html1.mh-extra.com/html/parker/uc-df/uc-df_quick-start-manual_756355005.webp)
C o n f i d e n t i a l P a r k e r S e a R e c o v e r y
0 6 1 2 2 0 1 7
ULTROclear ZK-A2F Typical Operation
35-50 psi source water pressure (in range)
75-130 psi membrane pressure (in range)
Up to 33 gph RO product flow (in range)
Pressure Relief Valve
Turn Clockwise (CW) to increase the relief pressure, default 60 psi
AUTO OPERATION:
With the direct feed (DF) ULTROclear RO system in the ON position and operating, the unit
will remain in operation until pressure in the feed line decreases to approximately 20 psi (default
adjustable). At 20 psi, the RO system will STOP. Once the pressure increases to more than 40 psi
(default), the RO system will automatically START and operate to produce RO product water.
RO PRODUCT
FLOW, 30 GPH
ZK-A2
(2 MEMBRANES)
INTERNAL PRESSURE
RELIEF BYPASS VALVE, 60
PSI SETPOINT
Summary of Contents for UC-DF