GENERAL

The ULTROclear (UC) Direct Feed (DF) low pressure reverse osmosis (RO) system is designed
to treat RO permeate/product water from an upstream first pass RO/watermaker system, directly
without intermediate break tanks. Installation of the Parker Sea Recovery low pressure
ULTROclear DF system is typically inside of a ship/vessel or inside of a building for land based
applications. The second pass RO system provides ultrapure water for spot free rinsing (zero
mineral deposits) and similar high purity applications.

Key Features:

Direct Feed operation treating first pass RO permeate directly without buffer tank(s)

Corrosion resistant low pressure RO system – coated aluminum frame

Run dry RO pump operation without damage – Robust & Reliable

Simple operation, ON & OFF automatic

Parker Quality – Parker Hannifin Corporation/Water Purification – Sea Recovery

INSTALLATION

Refer to the attached installation diagram

Step 1A:

Place the RO system in a suitable location in the ship or building with enough room for

maintenance and servicing.

Step 2A:

Secure the RO system down with appropriate anchorage and vibration mounts, as

necessary.

Step 3A:

Connect ½” tubing (Parker Nylon N series tubing) to the INLET port on the connection

panel. Feed water is supplied directly from an upstream RO watermaker. Typical supply pressure
is 20 to 50 psi.

Note: The UC can treat onboard potable water or dockside potable water in addition to direct-feed from the
watermaker.

Step 4A:

Connect ½” tubing to the BRINE port and route to drain or recycle back to the low

pressure piping of the seawater RO watermaker for 100% recovery.

Summary of Contents for UC-DF

Page 1: ... P a r k e r S e a R e c o v e r y 0 6 1 2 2 0 1 7 PARKER SEA RECOVERY ULTROCLEAR Direct Feed DF LOW PRESSURE REVERSE OSMOSIS RO 400 1500 GPD SECOND PASS RO SYSTEM DIRECT FEED 1 5 M3 day to 5 75 M3 day QUICK START GUIDE UC DF ...

Page 2: ...em coated aluminum frame Run dry RO pump operation without damage Robust Reliable Simple operation ON OFF automatic Parker Quality Parker Hannifin Corporation Water Purification Sea Recovery INSTALLATION Refer to the attached installation diagram Step 1A Place the RO system in a suitable location in the ship or building with enough room for maintenance and servicing Step 2A Secure the RO system do...

Page 3: ...ght and ready for operation INITIAL STARTUP AND OPERATION Step 1B Verify source water flow and pressure are available to the INLET of the low pressure RO system Step 2B Turn the black BRINE flow meter control knob clockwise CW until it is fully closed Then turn the black knob counterclockwise CCW two full turns partially open CAUTION Never operate the RO system with the black BRINE knob fully clos...

Page 4: ...ph max ZK A2F Two vessel rated flow 800 gpd 33 gph max ZK A3F Three vessel rated flow 1 200 gpd 50 gph max ZK A4F Four vessel rated flow 1 500 gpd 62 gph max Typical Filter Out Pressure 20 to 50 psi Typical Membrane Pressure range 75 to 130 psi Typical operation for a ZK A2F system is shown below producing 30 gph of RO PRODUCT water at 42 psi Filter OUT pressure BLACK BRINE FLOW METER CONTROL KNOB...

Page 5: ...sure default 60 psi AUTO OPERATION With the direct feed DF ULTROclear RO system in the ON position and operating the unit will remain in operation until pressure in the feed line decreases to approximately 20 psi default adjustable At 20 psi the RO system will STOP Once the pressure increases to more than 40 psi default the RO system will automatically START and operate to produce RO product water...

Page 6: ...ll be reduced Product water pressure 0 to 25 psi Brine pressure 0 20 psi UC Feed Power 2 amp 230V 3 amp 110V Typical operating power less than 175 watts low energy under hp 100 to 230V 1 phase 50 60 hz Common Options A Mounting pads for the low pressure RO unit a 4 2115030120 b 4 061142150020 c 4 061100049000 d Note Holes can be drilled into the base of the frame for mounting as applicable for the...

Page 7: ...al information for all pressure flow and conductivity in the system is required to be provided in the case of any warranty claims Pressure flows and conductivity must be provided for each flow stream with daily recordings photos and documentation ULTROclear DF System Cleaning The ULTROclear DF RO system should be cleaned when the membrane pressure is observed to increase by approximately 10 15 or ...

Page 8: ...nd other contaminants Deposits build up on the membrane surfaces during operation until they cause loss in normalized permeate flow loss of normalized salt rejection or both Membrane elements should be cleaned when one or more of the below mentioned parameters are applicable The normalized permeate flow drops 10 The normalized salt passage increases 5 10 The normalized pressure drop feed pressure ...

Page 9: ...ear DF Reverse Osmosis Overall Configuration Corrosion resistant durable low pressure RO system designed for use in marine environments ON OFF SELECTOR SWITCH PRIMARY ELECTRICAL CONNECTION 110V or 220V 1PH TWO PREFILTER HOUSINGS AND FILTER ELEMENTS RO VESSELS WITH MEMBRANE ELEMENTS ...

Page 10: ...C o n f i d e n t i a l P a r k e r S e a R e c o v e r y 0 6 1 2 2 0 1 7 Parker Water Purification Sea Recovery Contact Information ...

Page 11: ...onductivity Source water feed pressure PI 10 psi Filter out pressure PI 20 psi Membrane pressure PI 25 psi Concentrate pressure PI 35 psi Permeate pressure PI 50 psi RO permeate flow FI 50 gpm RO concentrate flow FI 40 gpm RO conc Recycle flow FI 35 Gpm RO permeate EC AIT50 HH Conductivity RO feed ORP at CF 20 CF 20 mV mV ...

Page 12: ...arts when water is fed into the system and stops when water no longer passes through The final product water is ultra pure capable of absorbing and pulling away dirt and debris from all surface finishes Simply plug into your watermaker to get endless spot free rinse water for your boat Made for sport fishing 40 100 ft 12 30 5 m Direct feed from the watermaker Simple and reliable add on easy to use...

Page 13: ...l 3 0 M3D 2 45 lbs 20 kg ZK A3F 116 ZK A3F 215 1200 Gal 4 50 M3D 3 50 lbs 23 kg ZK A4F 116 ZK A4F 215 1500 Gal 5 75 M3D 4 55 lbs 25 kg 0 5 tube product 0 5 tube inlet 0 5 tube brine ZK A4 F ZK A3 F ZK A2 F ZK A1 F Models Side view 110v 1ph 60hz 116 220V 1ph 50hz 215 2630 E El Presidio St Carson CA 90810 Toll Free 855 339 6899 Tel 310 608 5600 Fax 310 608 5692 Email waterpurification parker com Web...

Page 14: ......

Reviews: