TWP/TWB201 – TWP/TWB7501
28
MANUAL STEPPING
This feature is used to assist in maintenance and troubleshooting of the dryer. Touching the STEP button at the
main screen will advance thru the regeneration states. This allows the user to skip ahead to desired stages of the
regeneration process more quickly. Using this feature may yield worse than desired dewpoints until the dryer is
allowed to cycle uninterrupted. For safety, when attempting to switch out of repressurization or blowdown, the dryer
will wait until the pressures in the tanks are at a safe level before proceeding to the next state.
CAUTION: Never step through the cooling state. Doing so may result in extreme temperatures being released
downstream. Only switch out of cooling if you are certain there is no possibility of releasing dangerous heat
downstream.
CONTROLLER DISPLAY & OPERATION
The dryer’s controller is an Allen-Bradley® PLC coupled with a proprietary color, touch panel HMI. The controller
is factory programmed with the proper timing configurations for the dryer model. The controller features user
configurable drain settings, timing configuration, dewpoint demand cycles, system pressure and temperature
monitoring, system alarms with user configurable settings and alarm log, and a manual stepping feature for
maintenance. Additionally, there is reference information for troubleshooting dryer operation and alarms.
The standard controller display is accessible at the front of the dryer without opening the enclosure. If the enclosure
must be opened, always remember to close and secure the enclosure door when not using!
Summary of Contents for TWP/TWB201
Page 1: ...1 Externally Heated Blower Purge Desiccant Dryers User Manual Models TWP TWB201 TWP TWB7501...
Page 9: ...TWP TWB201 TWP TWB7501 9 TWP Desiccant Dryer Operation TWB Desiccant Dryer Operation...
Page 10: ...TWP TWB201 TWP TWB7501 10 FLOW SCHEMATIC MODELS TWP201 301...
Page 11: ...TWP TWB201 TWP TWB7501 11 FLOW SCHEMATIC MODELS TWP401 801...
Page 12: ...TWP TWB201 TWP TWB7501 12 FLOW SCHEMATIC MODELS TWP1001 1201...
Page 13: ...TWP TWB201 TWP TWB7501 13 FLOW SCHEMATIC MODELS TWP1501 7501...
Page 14: ...TWP TWB201 TWP TWB7501 14 FLOW SCHEMATIC MODELS TWB201 801...
Page 15: ...TWP TWB201 TWP TWB7501 15 FLOW SCHEMATIC MODELS TWB1001 1201...
Page 16: ...TWP TWB201 TWP TWB7501 16 FLOW SCHEMATIC MODELS TWB1501 7501...
Page 17: ...TWP TWB201 TWP TWB7501 17 TWP WIRING DIAGRAM STANDARD CONTROLLER...
Page 18: ...TWP TWB201 TWP TWB7501 18 TWP WIRING DIAGRAM STANDARD CONTROLLER...
Page 19: ...TWP TWB201 TWP TWB7501 19 TWP WIRING DIAGRAM STANDARD CONTROLLER...
Page 20: ...TWP TWB201 TWP TWB7501 20 TWP WIRING DIAGRAM STANDARD CONTROLLER...
Page 21: ...TWP TWB201 TWP TWB7501 21 TWB WIRING DIAGRAM STANDARD CONTROLLER...
Page 22: ...TWP TWB201 TWP TWB7501 22 TWB WIRING DIAGRAM STANDARD CONTROLLER...
Page 23: ...TWP TWB201 TWP TWB7501 23 TWB WIRING DIAGRAM STANDARD CONTROLLER...
Page 24: ...TWP TWB201 TWP TWB7501 24 TWB WIRING DIAGRAM STANDARD CONTROLLER...
Page 25: ...TWP TWB201 TWP TWB7501 25 PANEL LAYOUT STANDARD CONTROLLER...