background image

2

Mounting Information

90

°

10

°

10

°

V

Notes:
1.  Mount filter assembly as close to vertical (V) as possible. Do not 

exceed 10° from vertical or the assembly may not function properly.

2. Fastener size is 3/8˝ (M10) for mounting brackets.

1000FH

10.9 in

(27.7 cm)

Adjustable 
by ±2.1 in. 

(±5.3 cm)

4.5 in

(11.4 cm)

5.8 in.

(14.7 cm)

5.0 in

(12.7 cm)

900FH

11.0 in

(27.9 cm)

Adjustable to 

13.5 in

(34.3 cm)

5.8 in.

(14.7 cm)

4.5 in

(11.4 cm)

Installation Diagram

Valve 1

Valve 2

Fuel Tanks Above Filter

Do not exceed 39’ (11.9 m)

of head feet or 15 PSI.

Fuel Tank

(Pressure Side Installation)

A shut-off valve is 

recommended when the 

fuel tank is mounted higher 

than the filter

Fuel Tank Below Filter

Do not exceed 5’ (1.5 m) of lift

or 4 inches of mercury (inHg)

of inlet piping restrictions

Fuel Tank

(Ideal Vacuum 

Side Installation)

Fuel Tank

(Vacuum Side Installation)

Install a check valve 

(with light or no restriction) 

when tank is lower than filter

to maintain prime.

Pressure Side:

Fuel transfer pump not to 

exceed maximum PSI

or flow rate of filter.  

NOT ideal - pumps emulsify 

water hindering filter 

performance.

Fuel transfer pump

(IDEAL vacuum side installation)

Engine

Maintain a service clearance below

filter assembly of at least 2 in. (5.1 cm)

for draining and servicing bowl.

Valve 3

Suction (vacuum) Side: 

Primary (first) filter - use 30 micron.

If it is the 

only

 filter in the system, 

use 2 or 10 micron.

Maintain a clearance above the filter assembly 

of 5 in. (12.7 cm) (900FH), 

and 10 in. (25.4 cm) (1000FH)

for filter removal.

Optional Bypass Installation and Operation

(allows user to service filter without shutting down engine.)

Valves

1

2

3

Unit On-line

Open

Open

Closed

Unit Off-line

Closed

Closed

Open

Optional Vacuum Gauge: 

Helps in monitoring system restriction

and filter element life.

Summary of Contents for Racor Turbine Series

Page 1: ...r When heavy enough they too fall to the bottom of the collection bowl Stage 3 Filtration Proprietary Aquabloc cartridge filters repel water and remove contaminants from fuel down to 2 micron nominal Aquabloc cartridge filters are waterproof and effective longer than water absorbing filters Instruction Part Number 12960 Rev E Contact Information Parker Hannifin Corporation Racor Division P O Box 3...

Page 2: ...uum Side Installation Fuel Tank Vacuum Side Installation Install a check valve with light or no restriction when tank is lower than filter to maintain prime Pressure Side Fuel transfer pump not to exceed maximum PSI or flow rate of filter NOT ideal pumps emulsify water hindering filter performance Fuel transfer pump IDEAL vacuum side installation Engine Maintain a service clearance below filter as...

Page 3: ...bends with flexible fuel hose as kinks may occur Avoid the use of two 45 elbow fittings where one 90 elbow will work When routing hose avoid surfaces that move have sharp edges or get hot such as exhaust piping Priming Instructions 1 Remove T handle and lid from top of filter 2 Fill filter with clean fuel 3 Lubricate lid gasket and T handle O ring with clean fuel or motor oil 4 Replace lid and T h...

Page 4: ...is operated by turning the ignition switch ON for a minimum of five minutes prior to starting the engine HEATER WIRING INSTALLATION Caution Please read carefully before beginning installation See schematic on next page 1 Never power up the heater if there is no fuel in the Racor filter severe damage may result to the heater and filter assembly 2 During equipment or vehicle servicing always ensure ...

Page 5: ...RK 11862 Dual 2 RK 19490 24 Racor Heater Relay Kit Information Note Racor heater relay kits are ordered separately Battery Ignition Switch black 14 Green 14 red 14 white 18 Optional Toggle Switch Red 18 Black 14 Fuse Box 1A Min Inlet Port Racor Relay Kit Racor 3 wire Schematic Shown Note If your Racor heater has only 2 wires no white the relay White 18 wire simply goes to chassis ground White 18 ...

Page 6: ...cm Weight dry 6 0 lb 2 7 kg Clean Pressure Drop 0 30 PSI 0 021 bar Maximum Pressure1 15 PSI 1 03 bar Water In Bowl Capacity 10 3 oz 305 ml Available Options water detection kit 2 12 or 24 vdc heater 2 vacuum gauge 12 or 24 vdc primer pump Yes Yes Yes Yes Water Removal Efficiency 99 Ambient Temperature Range 40 o to 255 o F 40 o to 124 o C Maximum Fuel Temperature 190 F 88 C 1 Pressure installation...

Page 7: ... Body Feed thru Kit includes A B 6 5 RK 11815 103 Mounting Bracket Kit 6 RK 19663 RK 11 1679 3 wire Feed thru Heater Assembly Kit Body Feed thru Plug Kit 7 RK 11 2009 Kit Body Housing Return Tube includes B 3 pcs G 8 RK 11 1939 Conical Baffle and Turbine Centrifuge Kit includes B C D E 9 RK 11 1938 See thru Bowl with Drain and Plug Kit includes B F 10 10 RK 32204 Water Sensor Kit 11 RK 20126 Bowl ...

Page 8: ...h 7 0 in 17 8 cm Width 6 0 in 15 2 cm Weight dry 10 0 lb 4 5 kg Clean Pressure Drop 0 43 PSI 0 03 bar Maximum Pressure1 15 PSI 1 03 bar Water In Bowl Capacity 10 3 oz 305 ml Available Options water detection kit 2 12 or 24 volt dc heater 2 vacuum gauge 12 or 24 vdc primer pump Yes Yes Yes Yes Water Removal Efficiency 99 Ambient Temperature Range 40o to 255o F 40o to 124o C Maximum Fuel Temperature...

Page 9: ...2015 24 vdc Heater Body Feed thru Kit includes A B 6 5 RK 11815 103 Mounting Bracket Kit 6 RK 19663 RK 11 1679 3 wire Feed thru Heater Assembly Kit Body Feed thru Plug Kit 7 RK11 2010 Kit Body Housing Return Tube includes B 3 pcs G 8 RK 11 1939 Conical Baffle and Turbine Centrifuge Kit includes B C D E 9 RK 11 1938 See thru Bowl with Drain and Plug Kit includes B F 10 10 RK 32204 Water Sensor Kit ...

Page 10: ...h this surface Check O ring for damage Damaged worn or dirty seals will allow air ingestion Inspect and replace all seals as needed Clean the sealing surfaces of dirt or debris every time the filter is replaced If carriage bolt is loose do not overtighten it as this may distort the bracket position Heater feed thru O ring must not be damaged or swollen Tighten to 15 20 in lbs Air bubbles appearing...

Page 11: ...e outlet hole on fuel return tube if filter is removed and fuel will not flow to engine Instead punch emergency tab on the top of filter and leave in place Puncturing emergency tab will bypass all filtration and send unfiltered fuel to your engine Service filter as soon as possible to avoid harmful contaminants flowing downstream to the final filter or engine Water Sensors This feature alerts oper...

Page 12: ... TO PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL FAMILY OR HOUSEHOLD PURPOSES WARRANTIES OF DESCRIPTION WARRANTIES OF MERCHANTABILITY TRADE USAGE OR WARRANTIES OR TRADE USAGE Warning Failure or improper selection or improper use of the products and or systems described herein or related items can cause death personal injury and property damage This document and oth...

Reviews: