Electro hydraulic proportional controls version 45 for
axial piston pumps, PV series
Bulletin MSG30-3254-INST/UK
Installation and setup manual
13 Trouble shooting guide
Pump delivers no output flow
Drive motor does not turn
reason
solution
Motor is not connected correctly or one of the three phases has failed.
Motor does not turn smoothly when pump is disconnected from pump.
Check motor connections, check electrical power supply
.
reason
solution
Pump is mechanically blocked. Motor turns smoothly when disconnected from
pump.
Send pump for service to factory.
Drive motor only turns at slow speed
reason
solution
Motor is not selected properly. Installed motor has not enough torque.
Start pump at unloaded system. Use motor with more horse power.
reason
solution
Pump is hydraulically blocked. No function of compensator, no pressure relief
valve; Pump stops after e few turns.
Check function of pump compensator (see below). Start pump at unloaded
system.
Drive motor turns, pump does not turn
reason
solution
Coupling is not or not correctly mounted.
Check coupling assembly and correct it.
Drive motor turns and pump turns
reason
solution
Wrong direction of rotation.
Change direction of motor rotation.
reason
solution
Fluid reservoir empty or not filled to level, suction line ends above fluid level.
Fille reservoir to required level, if necessary increase suction pipe length.
reason
solution
Suction line is blocked. E. g. by plugs, cleaning tissues, plastic-plugs.
Ball valve in the suction line closed. Suction filter blocked.
Check suction line for free flow. Open valves in suction line.
Valves should be equipped with electrical indicator. Check suction filter.
reason
solution
Suction line not gas tight, pump gets air into suction port.
Seal suction line against air ingression.
reason
solution
Pressure line / system is not able to bleed air out.
Unload pressure port, unload system before start, bleed air from pressure line.
Pump does not build up pressure, but delivers full flow at low pressure
reason
solution
Standard pressure compensator is set to minimum pressure.
Adjust compensator setting to desired pressure.
reason
solution
No pressure pilot valve connected.
Install suitable pressure pilot valve and adjust it to the desired setting.
reason
solution
Multiple pressure pilot selector valve is not energized; Pump works in stand-by.
Energize selector valve solenoid.
reason
solution
Differential pressure at compensator is adjusted properly (too low).
Check differential pressure adjustment and correct it as described above.