
15
Parker Hannifin Manufacturing Germany GmbH & Co. KG
Pump & Motor Division Europe
Chemnitz, Germany
Electro hydraulic proportional controls version 45 for
axial piston pumps, PV series
Bulletin MSG30-3254-INST/UK
Installation and setup manual
Max. pressure
pilot valve
Flange ports ISO6162; DN,
PN; fit to PV, frame size BG; thread M
Cover and insert
DIN E NG2 quick
unload valve
Return port TE,
thread G
Alternative
outlet port P
2
,
thread G
2
Also available in
US-version ( UNC
threads and UNF
ports) and with
ports according to
ISO 6149
Gage port MpS, system
pressure, G1/4“
Port p system
pressure, G1/4“
Port p
P
, pilot
pressure, G1/4“
Gage port MpP,
pilot pressure, G1/4“
Port p
1
,G1/4“,
preloaded
pressure (covered)
Figure 13
Preload and quick unload manifold
Table 3: Main dimensions of the preload and quick unload manifold
dimension
BG1
BG2
BG3
BG4
BG5
BG6*
B[mm]
125
150
157
157
190
190
H[mm]
105
130
130
130
154
154
T[mm]
80
80
92
92
105
105
L[mm]
105
103
121
121
137,5
137,5
B1[mm]
189
189
196
196
239
239
H1[mm]
166
166
166
166
199
199
T1[mm]
116
116
137
137
155
155
for size
PV016 - 028 PV032 - 046 PV063 - 092 PV140 - 180 PV270
PV360
DN[mm]
19 (3/4”)
25 (1”)
32 (1 ¼”)
32 (1 ¼”)
38 (1 ½”) 38 (1 ½”)
PN[bar]
400
400
400
400
400
400
M
M10
M12
M12 (M14*) M12 (M14*) M16
M16
valve insertNG1
DIN E16
DIN E16
DIN E25
DIN E25
DIN E32 DIN E32
Qnominal[l/min]
160
160
300
300
550
550
valve insertNG2
DIN E16
DIN E16
DIN E16
DIN E16
DIN E25 DIN E25
Qnominal[l/min]
160
160
160
160
300
300
G (port TE)
½”
½”
½”
½”
¾”
¾”
G2 (opt. outlet)
¾”
1“
1 ¼”
1 ¼”
1 ½”
1 ½”
*1) optional for PV063 – PV180, thread option 4
*2) for BG6 PV360 the manifold of BG5 is used
Preload valve,
insert DIN E NG1