English
4/6
PST 090-340
is symptomatic of poor drainage.
Th
is check of the timed drain opening (parameter
d1
).
Settings depends upon the operating conditions of the dryer and
varies the amount of condensate to be removed.
For standard dryer operating conditions, see the following table of
recommended settings:
Model
Parameter d1
PST090-340
5
Parameter d1
: time open in seconds for every 2 minutes of opera-
tion.
c) EXTERNAL - if there is an external drain.
To change operation mode, use the parameter d3 (see par. 5.3 in List of
parameters).
Y
Only set the EXTERNAL mode in absence of the solenoid valve.
Otherwise the relative coil could become damaged.
Alarm log
Contains the descriptions of the last alarms (max. 8).
Press
é
for 5 seconds: the keypad now operates in Alarm
MENU mode and the events can be scrolled with
z
and
é
.
Every event is displayed with “ALx” (x=1-8).
AL1 = most recent event.
If there are no events “---” appears.
To view the details of the event, press
x
:
ALx
1 Alarm code
2 Th
ousands of hours
3 Hours
4 Dew point
5 Evaporation temperature
6 Compressor discharge temperature
Scroll with
z
and
é
.
5.3 Parameters
Accessing parameters
Press
z
and at the same time
é
: the keypad now operates in
Parameters MENU mode and the parameters can be scrolled with
z
and
é
.
List of parameters
A1
Sets the unit of measure for dew point in °C or °F.
A2/A3
Total hours of dryer operation = A2
(display only).
A4/A5
Like A2/A3 but for hours of refrigeration compressor ope-
ration.
A6
Sets Hd Warning intervention temperature (see par. 5.4 in
List of alarm/warnings).
A7
Inhibits remote OFF command.
b1
Sets the dryer address for serial communications.
b2
Sets the serial communication speed.
b3
Not available
b5
Refrigerant evaporation temperature.
b7
Not available
b8
Compressor discharge (delivery) temperature.
b9
Not available
C5
Dryer model:
Mon = models PST090-390
MuL = models PST490-1980
Note
: if the C5 is set to = MuL in a monocooler dryer then
the warning ASE will occur. ASE is a warning for the mul-
ticooler models..
C7
Sets compressor operation mode:
- CYC = CYCLING (energy saving enabled)..
- Con = CONTINUOUS (energy saving disabled)..
C36
Operating logic of the alarm/machine status relay.
0 = relay energised when dryer is running, de-energised if
in warning/alarm status.
1 = relay de-energised when dryer is running, energised if
in warning/alarm status.ù
2 = relay de-energised when dryer is not running,
energised when running.
C37
% energy saving.
d1
Sets the seconds of condensate drain opening (if set in TI-
MED mode).
d2
Like d1, but for seconds closed.
d3
ISets condensate drain operation mode:
- CAP = INTEGRATED
- tIM = TIMED
- Con = EXTERNAL (24VAC)
On the model PST090 , which does not includes the sensor B2, para-
meter C29 will also appear on display. Make sure that parameter C29 is
to set “0”.
Changing parameters
Aft er displaying the parameter, press
x
, change with
z
and
é
, ,
then press
x
to confi rm.
Press
y
to return to STANDARD mode.
5.4 Alarms and Warnings
Alarms
cause the dryer to switch off .
Warnings
only cause a signal.
In the case of Alarm or Dew Point Sensor Warning (dSE),
[
displays the alarm code. In the case of a Warning,
[
alternatively
displays the fault code and the dew point and WARNING LED comes
on.
If an alarm occurs:
a) Identify and eliminate the cause;
b) press
z
to reset the alarm;
c) press
x
to restart the dryer.
If a warning without automatic reset occurs:
a) identify and eliminate the cause
b) press
z
to reset the warning.
List of alarms/warnings
HP
High Pressure Alarm
CP
Phases monitor Alarm
LP
Low Pressure Alarm
Ld
Low Dew Point Alarm
Lt
Low Evaporation Temperature Alarm
Ht
High Compressor Discharge Temperature Alarm = T> 120°C.
rSE
Refrigerant Temperature Sensor Warning
Switches to CONTINUOUS mode.
drE
Condensate Drain Warning
Condensate drainage switches to TIMED mode.
dSE
Dew Point Sensor Warning
Th
e measured temperature must return within its normal ran-
ge.
Hd
High Dew Point Warning
Automatic reset when the dew point = A6 - 4°F (2°C).
HSE
Discharge temperature sensor Warning
Sr
Scheduled Maintenance Warning
See par. 5.2 and 6.3
Summary of Contents for PST090
Page 2: ......
Page 29: ... 8 5 Exploded drawing PST 090 Ac 9 PST 090 340 ...
Page 30: ... 8 5 Exploded drawing PST 130 175 Ac 10 PST 090 340 ...
Page 31: ... 8 5 Exploded drawing PST 250 340 Ac 11 PST 090 340 ...
Page 32: ... 8 5 Exploded drawing PST 250 340 Wc 12 PST 090 340 ...
Page 33: ... 8 6 Dimensional drawing PST 090 Ac 13 PST 090 340 ...
Page 34: ... 8 6 Dimensional drawing PST 130 175 Ac 14 PST 090 340 ...
Page 35: ... 8 6 Dimensional drawing PST 250 340 Ac 15 PST 090 340 ...
Page 36: ... 8 6 Dimensional drawing PST 250 340 Wc 16 PST 090 340 ...
Page 37: ... 8 7 Refrigerant circuit PST 090 175 Ac 17 PST 090 340 90 Ac 250 Ac 130 175 Ac 325 500 Ac ...
Page 39: ... 8 8 Wiring diagram PST 090 230V 1 60Hz Ac 19 PST 090 340 Sheet 1 5 ...
Page 40: ... 8 8 Wiring diagram PST 090 230V 1 60Hz Ac 20 PST 090 340 Sheet 2 5 ...
Page 41: ... 8 8 Wiring diagram PST 090 230V 1 60Hz Ac 21 PST 090 340 Sheet 3 5 ...
Page 42: ... 8 8 Wiring diagram PST 090 230V 1 60Hz Ac 22 PST 090 340 Sheet 4 5 ...
Page 43: ... 8 8 Wiring diagram PST 090 230V 1 60Hz Ac 23 PST 090 340 Sheet 5 5 5x20 24V 1A T ...
Page 44: ... 8 8 Wiring diagram PST 090 230V 3 60Hz Ac 24 PST 090 340 Sheet 1 6 ...
Page 45: ... 8 8 Wiring diagram PST 090 230V 3 60Hz Ac 25 PST 090 340 Sheet 2 6 ...
Page 46: ... 8 8 Wiring diagram PST 090 230V 3 60Hz Ac 26 PST 090 340 Sheet 3 6 ...
Page 47: ... 8 8 Wiring diagram PST 090 230V 3 60Hz Ac 27 PST 090 340 Sheet 4 6 ...
Page 48: ... 8 8 Wiring diagram PST 090 230V 3 60Hz Ac 28 PST 090 340 Sheet 5 6 ...
Page 49: ... 8 8 Wiring diagram PST 090 230V 3 60Hz Ac 29 PST 090 340 Sheet 6 6 ...
Page 50: ... 8 8 Wiring diagram PST 090 460V 3 60Hz Ac 30 PST 090 340 Sheet 1 6 ...
Page 51: ... 8 8 Wiring diagram PST 090 460V 3 60Hz Ac 31 PST 090 340 Sheet 2 6 ...
Page 52: ... 8 8 Wiring diagram PST 090 460V 3 60Hz Ac 32 PST 090 340 Sheet 3 6 ...
Page 53: ... 8 8 Wiring diagram PST 090 460V 3 60Hz Ac 33 PST 090 340 Sheet 4 6 ...
Page 54: ... 8 8 Wiring diagram PST 090 460V 3 60Hz Ac 34 PST 090 340 Sheet 5 6 ...
Page 55: ... 8 8 Wiring diagram PST 090 460V 3 60Hz Ac 35 PST 090 340 Sheet 6 6 ...
Page 56: ... 8 8 Wiring diagram PST 130 175 230V 3 60Hz Ac 36 PST 090 340 Sheet 1 6 ...
Page 57: ... 8 8 Wiring diagram PST 130 175 230V 3 60Hz Ac 37 PST 090 340 Sheet 2 6 ...
Page 58: ... 8 8 Wiring diagram PST 130 175 230V 3 60Hz Ac 38 PST 090 340 Sheet 3 6 ...
Page 59: ... 8 8 Wiring diagram PST 130 175 230V 3 60Hz Ac 39 PST 090 340 Sheet 4 6 ...
Page 60: ... 8 8 Wiring diagram PST 130 175 230V 3 60Hz Ac 40 PST 090 340 Sheet 5 6 ...
Page 61: ... 8 8 Wiring diagram PST 130 175 230V 3 60Hz Ac 41 PST 090 340 Sheet 6 6 ...
Page 62: ... 8 8 Wiring diagram PST 130 175 460V 3 60Hz Ac 42 PST 090 340 Sheet 1 6 ...
Page 63: ... 8 8 Wiring diagram PST 130 175 460V 3 60Hz Ac 43 PST 090 340 Sheet 2 6 ...
Page 64: ... 8 8 Wiring diagram PST 130 175 460V 3 60Hz Ac 44 PST 090 340 Sheet 3 6 ...
Page 65: ... 8 8 Wiring diagram PST 130 175 460V 3 60Hz Ac 45 PST 090 340 Sheet 4 6 ...
Page 66: ... 8 8 Wiring diagram PST 130 175 460V 3 60Hz Ac 46 PST 090 340 Sheet 5 6 ...
Page 67: ... 8 8 Wiring diagram PST 130 175 460V 3 60Hz Ac 47 PST 090 340 Sheet 6 6 ...
Page 68: ... 8 8 Wiring diagram PST 250 280 230V 3 60Hz Ac Wc 48 PST 090 340 Sheet 1 6 ...
Page 69: ... 8 8 Wiring diagram PST 250 280 230V 3 60Hz Ac Wc 49 PST 090 340 Sheet 2 6 ...
Page 70: ... 8 8 Wiring diagram PST 250 280 230V 3 60Hz Ac Wc 50 PST 090 340 Sheet 3 6 ...
Page 71: ... 8 8 Wiring diagram PST 250 280 230V 3 60Hz Ac Wc 51 PST 090 340 Sheet 4 6 ...
Page 72: ... 8 8 Wiring diagram PST 250 280 230V 3 60Hz Ac Wc 52 PST 090 340 Sheet 5 6 ...
Page 73: ... 8 8 Wiring diagram PST 250 280 230V 3 60Hz Ac Wc 53 PST 090 340 Sheet 6 6 ...
Page 74: ... 8 8 Wiring diagram PST 250 340 460V 3 60Hz Ac Wc 54 PST 090 340 Sheet 1 6 ...
Page 75: ... 8 8 Wiring diagram PST 250 340 460V 3 60Hz Ac Wc 55 PST 090 340 Sheet 2 6 ...
Page 76: ... 8 8 Wiring diagram PST 250 340 460V 3 60Hz Ac Wc 56 PST 090 340 Sheet 3 6 ...
Page 77: ... 8 8 Wiring diagram PST 250 340 460V 3 60Hz Ac Wc 57 PST 090 340 Sheet 4 6 ...
Page 78: ... 8 8 Wiring diagram PST 250 340 460V 3 60Hz Ac Wc 58 PST 090 340 Sheet 5 6 ...
Page 79: ... 8 8 Wiring diagram PST 250 340 460V 3 60Hz Ac Wc 59 PST 090 340 Sheet 6 6 ...
Page 83: ......