Mount the I/O Base

To  mount  the  I/O  base  on  a  wall  or  panel,  use  the  screw  holes 
provided in the base.

  IMPORTANT

The I/O module must be mounted on a grounded metal mounting 
plate or other conductive surface.

A mounting illustration for the base with an adapter is shown below.

Inches

(mm)

Adapter

2.0

(50)

2.0

(50)

1.9

(47.2)

4.02

(102)

1.81

(46)

4.32

(109.8)

5.39

(137.0)

Drill and Tap

for M4 Screw

2.39

(60.7)

3.02

(76.6)

3.13

(79.4)

5.98*

(151.9)

0.87

(22)

Drill and Tap

for M6 Screw

Ground Lug
Connection

Latching Mechanism

Mounting Base
  Keyswitch-
  Set to position 1
  for the PSST8M
  digital output
  modules

Install the Mounting Base as Follows:
  1. Lay  out  the  required  points  as  shown  above  in  the  drilling 

dimension drawing.

  2. Drill  the  necessary  holes  for  #8  (M4)  machine  or  self-tapping 

screws.

  3. Mount the base using #8 (M4) screws.
  4. Ground the system using the ground lug connection.  (The ground 

lug connection is also a mounting hole.)

* Depending on the type and number of manifolds, this dimension 

may vary.  Refer to Catalog 0600P-# for additional information.

Summary of Contents for PSST16M12A

Page 1: ...ct or systems in the current product catalog Due to the variety of operating conditions and applications for these products or systems the user through its own analysis and testing is solely responsib...

Page 2: ...n not in use store the equipment in appropriate static safe packaging ATTENTION Environment and Enclosure This equipment is intended for use in overvoltage Category II applications as defined in IEC p...

Page 3: ...60 7 3 02 76 6 3 13 79 4 5 98 151 9 0 87 22 Drill and Tap for M6 Screw Ground Lug Connection Latching Mechanism Mounting Base Keyswitch Set to position 1 for the PSST8M digital output modules Install...

Page 4: ...PSST8M12A 24V dc Out 0 1 2 3 4 5 6 7 Module Will Bridge Two Bases Wire the Output Modules Following are wiring instructions for the digital output modules view into connector Pin 1 Output 0 Pin 7 Out...

Page 5: ...2 Output Output 24VDC 500mA 3 Channel 4 Output Output 24VDC 500mA 4 Channel 6 Output Output 24VDC 500mA 5 Channel 8 Output Output 24VDC 500mA 6 Channel 10 Output Output 24VDC 500mA 7 Channel 12 Output...

Page 6: ...hat the PSST8M12A is now under the I O configuration Add 24 VDC Output Modules to RSLogix 5000 I O Configuration To add your output modules to RSLogix 5000 I O configuration follow these steps In RSLo...

Page 7: ...active and under control Flashing Red Open circuit detection No load Off State only Red Short circuit detected On State only Indication Probable Cause Module Status Off No power applied to device Gree...

Page 8: ...IEC 60068 2 2 Test Bb Un packaged Non operating Dry Heat 40 to 85 C 40 to 185 F Relative Humidity IEC 60068 2 30 Test Db Un packaged Non operating Damp Heat 5 to 95 Non condensing Shock IEC60068 2 27...