1.5 Adequate tube insertion.

 

 
Adequate tube insertion is essential. 
 
To achieve this, a Phastite Tube Marker should be used.  
 
To use the Phastite Tube Marker: 
 
Insert the tube into the Tube Marker. 
 
Ensure the tube is against the bottom of the bore (use the inspection hole to verify). 
 
While holding the tube, push and twist the Tube Marker one third of a turn. The higher the load applied the clearer the tube marks will 
be. 
 
The Phastite Tube Marker generates two lines on the tube. 
 
When inserting the tube into a Phastite connector the two lines should not be visible. This ensures adequate tube insertion prior to 
assembly. 
 
After assembly only one of the lines will be visible. If both lines are visible the tube slipped during assembly and the connection should 
not be used.   

 
 
 
1.6 PH-8-BENCHTOOL - Bench Mounting Bracket. 
 

If required the 

PH-8-HANDTOOL

 

Phastite Tool can be bench mounted by using a Bench Mount Bracket. 

 
The Bench Mount Bracket has four mounting holes as shown:  

 
 

 

 
 
 
1.7 Tube Preparation 
 

Ensure that the end of the tube is cut square and any burrs are removed without undue chamfering of the tube end. 

Summary of Contents for Phastite PH-8-HANDTOOL

Page 1: ...PH 8 HANDTOOL PH 8 BENCHTOOL PH 16 BENCHTOOL Operating Instructions PKLPAI 8 16 Page 1 of 10 ASSEMBLY INSTRUCTIONS PH 8 HANDTOOL PH 8 BENCHTOOL PH 16 BENCHTOOL...

Page 2: ...manent Connectors for 12mm 14mm 16mm 18mm 20mm 22mm and 25mm O D tube Inch Phastite Permanent Connectors for 1 2 5 8 3 4 7 8 and 1 O D tube A Phastite Permanent Connector can be a union straight elbow...

Page 3: ...sert 1 3 2 PH 16 BENCHTOOL 1 3 2 1 Assembly Ensure that insert and jaw are free from damage foreign bodies Slide insert into jaw Ensuring that the 2 location pins locate within the insert Once install...

Page 4: ...arks will be The Phastite Tube Marker generates two lines on the tube When inserting the tube into a Phastite connector the two lines should not be visible This ensures adequate tube insertion prior t...

Page 5: ...e tool ensuring that the Connector is orientated to the appropriate jaw insert see 1 2 for details D Re confirm adequate tube insertion by ensuring that both tube mark lines are hidden under the Phast...

Page 6: ...nector is orientated to the appropriate jaw insert see 1 2 for details D Re confirm adequate tube insertion by ensuring that both tube mark lines are hidden under the Phastite Collar E Apply pressure...

Page 7: ...se note the swivel nut is not shown in the following images to aid clarity G and 12mm Phastite sizes only PH 8 HANDTOOL PH 8 BENCHTOOL only Ensure that the Swivel Nut shoulder and Phastite Connector g...

Page 8: ...oved by approximately 12mm Release the pressure from the tool thus allowing the three cylinders to return to the rest position During the cylinder return stroke the removable cylinder can be lifted ou...

Page 9: ...require any additional information Call 1 800 CPARKER or go to www parker com for telephone numbers of the appropriate technical service department 2 6 Important receiving instructions Visually inspe...

Page 10: ...nd high loads IMPORTANT Phastite assembly equipment must only be serviced by a qualified parker technician For repair service contact the Authorized Parker Service Centre in your area Care must be tak...