background image

 

  

                          PH-8-HANDTOOL / PH-8-BENCHTOOL / PH-16-BENCHTOOL Operating Instructions  

PKLPAI-8-16 

 

 

        Page 3 of 10 

1.3 Jaw Insert assembly / disassembly: 

 
Ensure that the correct Jaw Inserts have been selected for the size and type of Phastite connector to be assembled, and jaw (see 
section 1.2).  
 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
1.3.1 PH-8-HANDTOOL  /  PH-8-BENCHTOOL 
 
1.3.1.1 Assembly. 
 

 

Ensure that insert and jaw are free from damage / foreign bodies. 

 

Slide insert into jaw. Ensuring that the guide flat is facing the main body of the tool and inserted into the jaw in the direction 
shown. 

 

  
 
 
 
 

 

Once installed the insert will be retained by a self energising locking system. 

 
1.3.1.2 Disassembly. 
 

 

The insert can removed from the jaw, simply by pulling. 

 

For smaller inserts a step is provided as shown. This can be used to remove the insert. 

 
 
 
 
 
 
1.3.2 PH-16-BENCHTOOL 
 
1.3.2.1 Assembly. 
 

 

Ensure that insert and jaw are free from damage / foreign bodies. 

 

Slide insert into jaw. Ensuring that the 2 location pins locate within the insert. 

 

Once installed retain the insert with the small socket cap screw provided 

 tighten hand tight only. 

 
1.3.2.2 Disassembly. 
 

 

The insert can removed from the jaw, simply by removing the small socket cap screw. 

 
 
 

1.4 Installing / Disconnecting Hose Couples. 
 

Only the coupling between the hose assembly and the pump should be disconnected. The hose assembly to tool connection must not 
be disconnected. 
 
An appropriate hose coupling has been supplied to suit 3/8 NPT ported equipment. If replaced the coupling must be selected to suit the 

pump and hose assembly and must be selected with all aspects of the application in mind. It is the user‟s responsibility to s

elect a 

suitable coupling.  

Fixed Jaw 

Moving Jaw 

Guide flat. 

Insertion Direction 

Step for insert removal 

Fixed Jaw 

Moving Jaw 

Summary of Contents for Phastite PH-16-BENCHTOOL

Page 1: ...PH 8 HANDTOOL PH 8 BENCHTOOL PH 16 BENCHTOOL Operating Instructions PKLPAI 8 16 Page 1 of 10 ASSEMBLY INSTRUCTIONS PH 8 HANDTOOL PH 8 BENCHTOOL PH 16 BENCHTOOL...

Page 2: ...manent Connectors for 12mm 14mm 16mm 18mm 20mm 22mm and 25mm O D tube Inch Phastite Permanent Connectors for 1 2 5 8 3 4 7 8 and 1 O D tube A Phastite Permanent Connector can be a union straight elbow...

Page 3: ...sert 1 3 2 PH 16 BENCHTOOL 1 3 2 1 Assembly Ensure that insert and jaw are free from damage foreign bodies Slide insert into jaw Ensuring that the 2 location pins locate within the insert Once install...

Page 4: ...arks will be The Phastite Tube Marker generates two lines on the tube When inserting the tube into a Phastite connector the two lines should not be visible This ensures adequate tube insertion prior t...

Page 5: ...e tool ensuring that the Connector is orientated to the appropriate jaw insert see 1 2 for details D Re confirm adequate tube insertion by ensuring that both tube mark lines are hidden under the Phast...

Page 6: ...nector is orientated to the appropriate jaw insert see 1 2 for details D Re confirm adequate tube insertion by ensuring that both tube mark lines are hidden under the Phastite Collar E Apply pressure...

Page 7: ...se note the swivel nut is not shown in the following images to aid clarity G and 12mm Phastite sizes only PH 8 HANDTOOL PH 8 BENCHTOOL only Ensure that the Swivel Nut shoulder and Phastite Connector g...

Page 8: ...oved by approximately 12mm Release the pressure from the tool thus allowing the three cylinders to return to the rest position During the cylinder return stroke the removable cylinder can be lifted ou...

Page 9: ...require any additional information Call 1 800 CPARKER or go to www parker com for telephone numbers of the appropriate technical service department 2 6 Important receiving instructions Visually inspe...