Measurement temperature point position and ATEX Classes

Seal

Planetary gearbox

Motor part

The temperature is measured on the metal surface next to the seal around the output shaft on all air motors except for some 1600 watts air motors.

Air Motor  
Order Code

Measuring Point

P1VAS160A0960

At 0 and 48 mm from top face (seal level)

P1VAS160A0016

At 0 and 57 mm from top face (seal level)

P1VAS160A0250

At 0 and 48 mm from top face (seal level)

P1VAS160A0120

At 0 and 48 mm from top face (seal level)

Air Motor  
Order Code

ATEX Classes

P1VAS012A*N00

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS012A*550

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS012A*360

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS012A*140

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS012A*090

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS012A*060

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS012A*010

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020A*G00

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020A*460

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS020A*240

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS020A*140

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS020A*070

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020A*036

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020A*018

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020A*005

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030A*E50

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030A*460

II 2G Ex h IIC T3 Gb X  II 2D Ex h IIIC T195°C Db X

P1VAS030A*240

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS030A*123

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS030A*070

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030A*036

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030A*018

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030A*010

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030A*005

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS060A*D50

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS060A*550

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS060A*400

II 2G Ex h IIC T3 Gb X  II 2D Ex h IIIC T195°C Db X

P1VAS060A*300

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS060A*200

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS060A*070

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS060A*050

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS060A*034

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS060A*018

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS090A*C60

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS090A*520

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS090A*367

II 2G Ex h IIC T3 Gb X  II 2D Ex h IIIC T195°C Db X

P1VAS090A*285

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS090A*190

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS090A*065

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS090A*047

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS090A*031

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS160A*960

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS160A*250

II 2G Ex h IIC T3 Gb X  II 2D Ex h IIIC T195°C Db X

P1VAS160A*120

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS160A*070

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS160A*032

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS160A*020

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS160A*016

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

Air Motor  
Order Code

ATEX Classes

P1VAS012D*N00

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS012D*550

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS012D*360

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS012D*140

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS012D*090

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS012D*060

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS012D*010

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020D*G00

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020D*460

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS020D*240

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS020D*140

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS020D*070

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020D*036

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020D*018

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS020D*005

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030D*E50

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030D*460

II 2G Ex h IIC T3 Gb X  II 2D Ex h IIIC T195°C Db X

P1VAS030D*240

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS030D*123

II 2G Ex h IIC T4 Gb X  II 2D Ex h IIIC T130°C Db X

P1VAS030D*070

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030D*036

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030D*018

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030D*010

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

P1VAS030D*005

II 2G Ex h IIC T6 Gb X  II 2D Ex h IIIC T80°C Db X

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Test in the ATEX zone after about 1.5 hours of operation, measure the surface and ambient temperature and record the values in writing. The 
measured ambient temperature is subtracted from the measured surface temperature and 40°C is added. The maximum surface temperature thus 
calculated must not exceed the maximum surface temperature allowed. If the measured value is greater than the maximum value indicated then the 
PNEUMATIC MOTEUR should be stopped immediately and consult your local partner. 
 

Summary of Contents for P1VAS Series

Page 1: ...en Pneumatik komponenten zu trennen Siehe ISO 4414 1982 bzw DIN 24 558 bez glich der Sicherheitsvorschriften bei Installation und Einsatz von Pneumatikkomponenten Air Motors Insert item part number pr...

Page 2: ...P1VAS motor is equipped as standard with food grade grease in the planetary gearbox An oil which is approved by the food industry is also available if supplementary lubrication is required Working pre...

Page 3: ...n not be operated against a mechanical stop since this would cause damage to the last stage of the planetary gear The motor package is stronger than the last planetary stage It is not possible to prov...

Page 4: ...060A 070 690 1190 14 P1VAS060A 050 800 2030 16 P1VAS060A 034 800 2030 16 P1VAS060A 018 800 2030 16 P1VAS090A C60 690 1190 14 P1VAS090A 520 690 1190 14 P1VAS090A 367 690 1190 14 P1VAS090A 285 690 1190...

Page 5: ...S6 4447865C P1VAS030A 070 P1VAS030D 070 P1VAS6 4447861M P1VAS6 4447863B P1VAS6 4447864B P1VAS6 4447865C P1VAS030A 036 P1VAS030D 036 P1VAS6 4447861M P1VAS6 4447863B P1VAS6 4447864B P1VAS6 4447865C P1VA...

Page 6: ...the Declaration of Conformity are observed and its provisions are followed The Parker air motor is suited for standard use in explosion Ex areas Design group II Use in endangered areas except in under...

Page 7: ...l damage or injury may be caused by the hot moving parts of the P1VASmotors in the presence of explosive gas mixtures and concentrations of dust potentially explosive atmosphere oil acids gases vapour...

Page 8: ...6 Gb X II 2D Ex h IIIC T80 C Db X P1VAS090A 367 II 2G Ex h IIC T3 Gb X II 2D Ex h IIIC T195 C Db X P1VAS090A 285 II 2G Ex h IIC T4 Gb X II 2D Ex h IIIC T130 C Db X P1VAS090A 190 II 2G Ex h IIC T4 Gb X...

Page 9: ...9 UK...

Page 10: ...tinu sans lubrification option C En standard le r ducteur plan taire est pr lubrifi en usine l aide d une graisse approuv e par l industrie agro alimen taire Une huile galement agr e est disponible si...

Page 11: ...e silencieux qui le plus souvent sont viss s directement sur l orifice d chappement du moteur Il existe cet effet plu sieurs mod les en laiton fritt et en plastique fritt L air vacu tant puls il est a...

Page 12: ...AS060A 200 690 1190 14 P1VAS060A 070 690 1190 14 P1VAS060A 050 800 2030 16 P1VAS060A 034 800 2030 16 P1VAS060A 018 800 2030 16 P1VAS090A C60 690 1190 14 P1VAS090A 520 690 1190 14 P1VAS090A 367 690 119...

Page 13: ...47861M P1VAS6 4447863B P1VAS6 4447864B P1VAS6 4447865C P1VAS030A 070 P1VAS030D 070 P1VAS6 4447861M P1VAS6 4447863B P1VAS6 4447864B P1VAS6 4447865C P1VAS030A 036 P1VAS030D 036 P1VAS6 4447861M P1VAS6 44...

Page 14: ...ion de conformit sont respect es et ses dispositions sont suivies Les moteurs pneumatiques Parker sont con us pour une utilisation en zone explosive ATEX Suivant groupe II Utilisation dans les zones h...

Page 15: ...xplosifs ou les concentrations de poussi res associ s aux pi ces chaudes et mobiles des moteurs P1VAS peuvent provoquer des incidents graves voire fatals 1 A t il t tabli avec certitude l installation...

Page 16: ...4 Gb X II 2D Ex h IIIC T130 C Db X P1VAS160A 070 II 2G Ex h IIC T4 Gb X II 2D Ex h IIIC T130 C Db X P1VAS160A 032 II 2G Ex h IIC T4 Gb X II 2D Ex h IIIC T130 C Db X P1VAS160A 020 II 2G Ex h IIC T6 Gb...

Page 17: ...17 FR...

Page 18: ...ilterung 5 m Standardfilter Taupunkt 3 C k hlgetrocknet und lkonzentration 1 0 mg l m was bei einem Standardkompressor mit Standardfilter gegeben ist seine Bahn gelangt Installationsanweisungen f r P1...

Page 19: ...die Leistungsausbeute des Motors reduziert wird Schallpegel Die Schallpegel in der folgenden Tabelle wurden bei Leerlaufdrehzahl mit einem im Abstand von 1 m vom Druckluft Motor aufgestellten Messinst...

Page 20: ...0A 070 690 1190 14 P1VAS060A 050 800 2030 16 P1VAS060A 034 800 2030 16 P1VAS060A 018 800 2030 16 P1VAS090A C60 690 1190 14 P1VAS090A 520 690 1190 14 P1VAS090A 367 690 1190 14 P1VAS090A 285 690 1190 14...

Page 21: ...1VAS6 4447865C P1VAS030A 070 P1VAS030D 070 P1VAS6 4447861M P1VAS6 4447863B P1VAS6 4447864B P1VAS6 4447865C P1VAS030A 036 P1VAS030D 036 P1VAS6 4447861M P1VAS6 4447863B P1VAS6 4447864B P1VAS6 4447865C P...

Page 22: ...dass sich der Parker Motor f r die Anwendung in explosionsgef hrdeten Bereichen eignet Ger tegruppe II Verwendung in explosionsgef hrdeten Bereichen ausgenommen Untertage und bertageanlagen im Bergbau...

Page 23: ...nnen zu schweren oder t dlichen Verletzungen f hren 1 Ist bei Montage des Motors sichergestellt dass keine explo sionsgef hrlichen Atmosph ren le S uren Gasen D mp fe oder Strahlungen vorkommen 2 Lieg...

Page 24: ...IC T80 C Db X P1VAS160A 250 II 2G Ex h IIC T3 Gb X II 2D Ex h IIIC T195 C Db X P1VAS160A 120 II 2G Ex h IIC T4 Gb X II 2D Ex h IIIC T130 C Db X P1VAS160A 070 II 2G Ex h IIC T4 Gb X II 2D Ex h IIIC T13...

Page 25: ...25 DE...

Page 26: ...orway parker com PL Poland Warsaw Tel 48 0 22 573 24 00 parker poland parker com PT Portugal Tel 351 22 999 7360 parker portugal parker com RO Romania Bucharest Tel 40 21 252 1382 parker romania parke...

Reviews: