Parker P1V-A160B Series Manual Download Page 11

11

www.parker.com/euro_pneumatic

Summary of Contents for P1V-A160B Series

Page 1: ...r the surrounding area Important instructions relating to explosion protection Application tips and other useful information Definition Potentially explosive atmosphere hereinafter referred to as Ex a...

Page 2: ...s apply Warranty and liability claims in regards to persons or equipment damage are invalid if one or several of the following causes apply Use of the equipment in a non designated application Imprope...

Page 3: ...class of T6 may not exceed a maximum surface temperature of 85 C Motor should be tested to ensure that the permissible temperature does not exceed 80 C there is a safety margin of 5 C This is the maxi...

Page 4: ...be covered by a contact guard 8 8 0 72 1 28 2 9 5 75 9 9 24 48 83 132 200 275 390 10 9 1 02 1 8 4 1 8 1 14 34 67 117 185 285 390 550 12 9 1 21 2 15 4 95 9 7 16 5 40 81 140 220 340 470 660 70 0 46 0 8...

Page 5: ...sure that the flow pressure at the motor connection side is 6 bar 85 PSI A higher air pressure leads to increased wear and tear install a pressure regulator An air pressure below 6 bar reduces the po...

Page 6: ...ent temperature in accordance 5 3 with requirements Has it been certified that the air motor is sufficiently ventilated and that there is no 5 5 additional warming source such as a clutch Is a formal...

Page 7: ...the disassembly original spare parts and the trained repair specialists that can adjust the air motor to the correct gap play The gap play determines the motors power efficiency and life expectancy 7...

Page 8: ...lubrication these motors can operation 100 of the time Black vanes C E For continuous lubrication free operation To obtain the longest possible service life we recommend no oil in the air Order code...

Page 9: ...y do not usually carry the CE mark Nevertheless most P1V M motors carry the CE mark because they are ATEX certified for use in explosive atmospheres The following are the currently applicable directiv...

Page 10: ...and of motor bearing cover Air pressure is Increase air too low pressure No air shut off Open shut off valve is closed valve Hose diameter Use a hose with a is too small larger diameter Exhaust air i...

Page 11: ...11 www parker com euro_pneumatic...

Page 12: ...Netherlands Oldenzaal Tel 31 0 541 585 000 parker nl parker com NO Norway Asker Tel 47 66 75 34 00 parker norway parker com PL Poland Warsaw Tel 48 0 22 573 24 00 parker poland parker com PT Portugal...

Reviews: