Parker Hannifin S.p.A. S.B.C. Division                                               

                   

user’s manual PSU

 

 

9

 

3.Module connections 

 

3.1.1.

 

Rail system 

 

 

 

 

 

 

 

External components 

may not

 be connected to the rail system. 

 

Maximum no. of TPDM modules in a combination: 15 modules 
 

3.1.2.

 

Communication connection 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24Vdc

- DCbus

Earth 

+ DCbus

0Vdc 

Use the dedicate fixing plates. 
On  the  right  side  of  the  last  module,  and  on  the 
left  side  of  the  first  module  insert  the  closing 
protection: 

 

 

IN

OUT

IN

OUT

Protective  covers: 

the  user  is 

responsible  for  protective  covers 
and/or additional safety measures in 
order to prevent damages to persons 
and electric accidents. 

Address setting  

Switch  Value upon ON 

16 

32 

64 

Range: 0,16,32,48,64,80,96,112 
Settings:      left: OFF 

      right: ON 

1

st

 

Module

 address = basic address  

 

 

IN 

OUT 

The communication in the axis combination is implemented via a SSK28 
cable and double RJ45 sleeves on the device top. Beginning with the TPD 
(mains  module)  the  connection  is  always  made  from  X30  to  X31  of  the 
next  device.  On  the  first  device  (X31)  and  the  last  device  (X30)  in  the 
multi-axis combination, a bus termination plug (BUS07/01) is required. 
 

Serial connection of up to 32 axes (or 15 modules)

 

Caution!

  Risk  of  Electric  Shock. 

Discharge  time  of  the  bus  capacitor 
is approx. 10 minutes.

 

Summary of Contents for P10

Page 1: ...1 User s manual Rev 0 January 2011 PSU...

Page 2: ...Parker Hannifin Divisione S B C EME Division and of its licensees and they shall not be copied or used without express authorization Parker Hannifin S p A Divisione S B C is committed to a continuous...

Page 3: ...s 5 1 2 2 Cable 5 1 2 3 Grounding 5 1 2 4 PSU protections 5 1 2 5 Hardware PSU 6 2 MOUNTING 7 2 1 Connectors layout 8 2 1 1 LED Status 8 2 1 2 Signal connectors 8 3 MODULE CONNECTIONS 9 3 1 1 Rail sys...

Page 4: ...PSUPx0 Mains module 3AC 230 480V nominal power in 1kW 10 10kW 20 20kW 30 30kW D6 Designation nominal supply 3 Configuration and parameterization interface USB USB connection 4 Options Mxx I O extensi...

Page 5: ...1 2 Nm M5 Braking resistor X40 Section 0 25 4mm2 AWG23 11 0 25 4mm2 AWG23 11 Tightening torque 0 5 Nm M4 0 5 Nm M4 Mains X41 Section 0 5 6mm2 AWG20 10 0 5 16mm2 AWG20 6 Tightening torque 1 2 Nm M5 1 7...

Page 6: ...41 41 36 Peak output current 5 sec Arms 36 36 30 72 72 60 82 82 72 Power kW 6 10 10 12 20 20 17 30 30 Internal capacitance F 550 1175 1175 Total capacity applicable F 2400 5000 5000 External braking...

Page 7: ...on user s manual PSU 7 2 Mounting 100mm 360mm 263mm 96mm 400mm 90 50 5mm 101mm PSU Weight Size 1 P10 3 95 kg Size 2 P20 P30 6 5 kg P20 Dimensions Size Lenght mm Height mm Depht mm 1 50 360 410 270 2 1...

Page 8: ...U completed Flashes slowly Serial communication error Flashes quickly Flashes quickly Ready On Off 2 1 2 Signal connectors X41 Mains X40 Braking resistor 1 L1 R Braking resistor No short circuit prote...

Page 9: ...safety measures in order to prevent damages to persons and electric accidents Address setting Switch Value upon ON 1 16 2 32 3 64 Range 0 16 32 48 64 80 96 112 Settings left OFF right ON 1st Module a...

Page 10: ...etwork must be provided with a separating transformer Then the PSU device is operated locally like in a TN network The secondary sided center of the separating transformer must be grounded and connect...

Page 11: ...User Manual Rev 0 January 2011 First edition For other informations log into website www sbcelettronica com Arranges to the manual data can be made by the manufacturer without advance notice The data...

Page 12: ......

Reviews: