Parker Hannifin S.p.A. S.B.C. Division
user’s manual PSU
9
3.Module connections
3.1.1.
Rail system
External components
may not
be connected to the rail system.
Maximum no. of TPDM modules in a combination: 15 modules
3.1.2.
Communication connection
24Vdc
- DCbus
Earth
+ DCbus
0Vdc
Use the dedicate fixing plates.
On the right side of the last module, and on the
left side of the first module insert the closing
protection:
IN
OUT
IN
OUT
Protective covers:
the user is
responsible for protective covers
and/or additional safety measures in
order to prevent damages to persons
and electric accidents.
Address setting
Switch Value upon ON
1
16
2
32
3
64
Range: 0,16,32,48,64,80,96,112
Settings: left: OFF
right: ON
1
st
Module
address = basic address
IN
OUT
The communication in the axis combination is implemented via a SSK28
cable and double RJ45 sleeves on the device top. Beginning with the TPD
(mains module) the connection is always made from X30 to X31 of the
next device. On the first device (X31) and the last device (X30) in the
multi-axis combination, a bus termination plug (BUS07/01) is required.
Serial connection of up to 32 axes (or 15 modules)
Caution!
Risk of Electric Shock.
Discharge time of the bus capacitor
is approx. 10 minutes.