K3.1.114o Manual NitroFlow Mobile
- 14 -
Parts
NitroFlow
®
Basic Mobile
1x Generator
1x Manual
Options (on demand)
Storage vessel
Vac/Hz NitroFlow
®
Basic Mobile LP
NitroFlow
®
Basic Mobile HP
120 / 60
159.003727
159.003364
230 / 50
159.003728
159.003340
4.2 Capacity
data
Generator
Nominal production capacity Nlpm*
Purity%
99.9 99.7 99.5 99 98 97 96 95 93
LP**
10
15
18
24 31 35 40 43 50
HP**
7.6 12
13
18 23 26 30 32 38
*Capacity at nominal conditions:
x
Ambient temperature: 20 °C / 68 °F
x
Ambient pressure: 1013 mbar(a)
** LP = Low Pressure, max. 2 bar(g) / 29 psig nitrogen pressure
** HP = High Pressure, max. 8 bar(g) / 116 psig nitrogen pressure
4.3 Maintenance
parts
Part Part
number
Maintenance kit: 1 x Carbon adsorber
159.003754
Oxygen sensor
159.005574
In case the compressor(s) need to be replaced, the correct part numbers are:
Part Part
number
Air compressor LP/LP (
230V/50Hz
) 159.005576
Air compressor LP/LP (
115V/60Hz
) 159.005578
Nitrogen compressor LP/HP (
230V/50Hz
)
159.005575
Nitrogen compressor LP/HP (
115V/60Hz
)
159.005577