background image

14  

15  

Summary of Contents for MiniKrimp 94C-001-PFD

Page 1: ...MiniKrimp Crimping Machine Technical Manual...

Page 2: ...AGE Before selecting or using any Parker hose or fittings or related accessories it is important that you read and follow Parker Safety Guide for Selecting and Using Hose Fittings and Related Accessor...

Page 3: ...eiving Instructions UNPACKING Carefully remove all documents and components from shipping containers INSPECTION Visually inspect all components for shipping damage If any shipping damage is found noti...

Page 4: ...corrosion resistant Features of the MiniKrimp with Hand Pump Lightweight portable compact all in one unit Unit with pump weighs only 42 pounds 10 000 psi and 30 tons of force No gauges to set exclusiv...

Page 5: ...ighly corrosion resistant Features of the MiniKrimp with Air over Hydraulic Pump Lightweight portable compact all in one unit Unit with pump weighs only 45 pounds 10 000 psi and 30 tons of force No ga...

Page 6: ...with 94C 001 PFD MiniKrimp Hand Pump Model Part 025349 Replacement Connector Replacement stainless steel bent tube rigid connector For use with 94C 002 PFD MiniKrimp Air Over Hydraulic Model Accessor...

Page 7: ...ose is designed to be used when mounting a hand pump 015301 to the MiniKrimp stand 94C MKS base Part 015736 Side Vise Mount Material High strength steel Mount connects to the side of the MiniKrimp usi...

Page 8: ...proved for use with the MiniKrimp without expressed written consent from Parker Parflex Division s technical support Any worn connectors should be replaced immediately MiniKrimp with Hand Pump Hand Pu...

Page 9: ...MiniKrimp is ready for operation Reference the Enerpac pump manual for operating instructions 1 IF APPLICABLE Relieve pressure from attached pump Remove the hand pump and bent tube assembly from the b...

Page 10: ...ned Steel Sleeve 1 015303 Custom Cylinder 1 015304 Aluminum Frame 1 015305 Cup Pusher 1 015306 Bent Tube Assembly 1 015310 3 8 x 3 8 Shoulder Bolt 1 015415 Spring Plunger 1 6 CTX S 3 8 37 to 1 4 NPT E...

Page 11: ...3 Custom Cylinder 1 015304 Aluminum Frame 1 015305 Cup Pusher 1 015310 3 8 x 3 8 Shoulder Bolt 1 015415 Spring Plunger 1 6 2 CTX S 3 8 37 to 1 8 NPT Elbow 1 6 6 CTX S 3 8 37 to 3 8 NPT Elbow 1 822011...

Page 12: ...the crimp shell Hose Visually inspect both ends of hose for square cut Remove any burrs loose fibers or wires Fittings Verify fitting series corresponds to the selected hose Visually inspect fitting s...

Page 13: ...osition ring so it is centered on die Reference Crimp Die Selection on Crimpsource online at www parker com crimpsource Die Spacer Ring Pakalign Feature Assemble hose Insert hose and fitting from bott...

Page 14: ...ose assembly length Measure crimp diameter of each fitting at top middle and bottom of shell Take measurements at a minimum of three places around shell circumference Verify crimp diameter is within t...

Page 15: ...2 lithium grease Dow Corning GN assembly paste or equivalent to prevent wear Die cavity in base plate worn or faulty If all crimp diameters are out of specification by the same amount the die cavity...

Page 16: ...egarding Accessories Trouble Shooting Warranty Policy and Safety Guide refer to the MiniKrimpTM Technical Manual Bul 4660 MKD Where do I purchase Enerpac Replacement Oil for my MiniKrimp machine The P...

Page 17: ...product is defective the product must be delivered or shipped freight prepaid to the nearest ENERPAC Authorized Service Center The customer should contact ENERPAC to locate and Authorized Service Cen...

Page 18: ...15...

Page 19: ...isture content of the Hose at any particular time and other factors The following are considerations for electrically nonconductive and conduc tive Hose For other applications consult the individual c...

Page 20: ...and other hazards can result when using the wrong Hose for such applications The system designer must take into account the fact that this permeation will take place and must not use Hose or Fitting i...

Page 21: ...division 3 5 Field Attachable Permanent Do not reuse any field attachable Hose Fitting that has blown or pulled off a Hose Do not reuse a Parker per manent Hose Fitting crimped or swaged or any part...

Page 22: ...Assemblies will fail if they are not replaced at proper time intervals Usually these failures are the result of some form of misapplication abuse wear or failure to perform proper maintenance When Hos...

Page 23: ...20...

Page 24: ...ts Reserved Parker Hannifin Corporation Parflex Division 1300 North Freedom Street Ravenna Ohio 44266 Phone 330 296 2871 Fax 330 296 8433 www parker com CERTIFIED ISO 9001 Accredited by the Dutch Coun...

Reviews: