7.
[Optional]
Joint F can be verified to be fully seated by disconnecting the Pin Catch (Y-63700-134-2) from the Anti-
Rotation Sub (Y-63700-161-1), fully exposing Joint F. Confirm the undercut/thread relief on Inner Member (Y-63700-
103-1) is 50% exposed.
8. Install (2) Bonded Rebound Stacks (J-28348-45).
9. Apply LOCTITE 243 on center thread of Inner Member (Y-63700-103-1).