27
IQAN-MD4 Technical Overview
Appendix A
Instruction book, IQAN-MD4
Appendix A
IQAN-MD4 Technical Overview
Absolute Maximum Ratings
a
a.The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be subjected without damage.
This doesn´t
imply that the device will function at these extreme conditions,
only that, when these conditions are removed and the device operated
within the “Recommended Operating Conditions”, it will still be functional and its useful life won’t have been shortened.
Ambient temperature
-30 to 70 °C
Storage temperature
-40 to 85 °C
Voltage supply on +BAT
6.5 to 36 V
Reverse polarity protection on +BAT
36 V with external 20A fuse (recommended fuse 3A to 5A)
Voltage on any pin with respect to -BAT
36 V
Environmental ratings
Climate environment
Enclosure, water & dust protection
Salt mist
Damp heat cyclic
Damp heat steady state
Heat, operation
Cold
Change of temperature
IEC 60529:2001, IP65; (front and back)
IEC 60068-2-52:1996 Kb, 72 h
IEC 60068-2-30:2005 Db, +55°C, 95% RH, 6 cycles
IEC 60068-2-78:2001 Cab, +40°C, 93% RH, 21 days
IEC 60068-2-2:2007 Bb, +70°C, 72 hours
IEC 60068-2-1:1993 Ab, -30°C, 16 hours
IEC 60068-2-14:1984 Nb, - 30°C to +55°C, 10 x 8 hours
Mechanical environment
Random vibration, MD4-7
Random vibration, MD4-5
Random vibration, MD4-10
Bump
IEC 60068-2-64: 2008 Fh, 15 - 1000 Hz, 7.1 Grms, 3 x 10 h
IEC 60068-2-64: 2008 Fh, 15 - 2000 Hz, 4.0 Grms, 3 x 10 h
IEC 60068-2-64: 2008 Fh, 15 - 2000 Hz, 4.0 Grms, 3 x 10 h
IEC 60068-2-27:2008 Ea, 40 g, 6 ms, 1000 * 6 dir
EMC
Radiated emission
Conducted emission, MD4-7
Conducted emission, MD4-5
Conducted emission, MD4-10
Conducted emission, transients
Conducted susceptibility
Radiated susceptibility
Conducted transients susceptibility
ESD, Operation
ESD, Handling
ISO 13766:2010/ISO 14982:2009
EN 55025:2008, 0.15-108 MHz, Class 2
EN 55025:2008, 0.15-108 MHz, Class 2
EN 55025:2008, 0.15-108 MHz, Class 1
ISO 7637-2:2004, 12/24 V, Level 2
ISO 11452-4:2005, 1 - 200 MHz, 1 kHz, 80% AM, 150 mA
ISO 11452-2:2004, 200-2000 MHz, 1kHz, 80% AM, 100 V/m
ISO 11452-2:2004, 800-2000 MHz, PM 577 µs / 4.6 ms, 60 V/m
ISO 7637-2:2004, Pulse 1, 2a, 2b, 3a, 3b, 4, Level 3; Pulse 5, Level 1
ISO 7637-3:2007, Level 3
ISO 10605:2008, 8 kV (contact), 25 kV (air)
ISO 10605:2008, 8 kV (contact)