25
Low-side digital outputs
Instruction book, IQAN
Low-side digital outputs
The low-side digital outputs are designed to drive small loads, e.g. lamps and buzzers.
Low-side digital outputs work by grounding a signal through the module. See
Appendix A for maximum loads per output.
EXAMPLE
Connect the lamp to the low-side digital outputs using a DOUT(LS) position, and
the +BAT, as supply.
Connecting a switch to DOUT(LS)-X and +BAT.
+BAT
DOUT(LS)-X
IQAN module
load