![Parker GS100 User Manual Download Page 25](http://html.mh-extra.com/html/parker/gs100/gs100_user-manual_755506025.webp)
Parker Hannifin Corporation
– GS100 User Manual
24
Sensor Configuration Messages
Configuration Message Format
Speed Sensor Configuration Parameter Read/Write/Response
(1)
PGN
PF
PS
SA
Parameter Group Definition
0xEF00 (61184)
239
DA
(2)
SA
Proprietary A
Data
Byte
Length
Parameter Name
Format
1
1 byte
Command Type
Unsigned Integer, message function for configuring Speed Sensor. Value is 0x81.
2
1 byte
Configuration Parameter Number
Unsigned Integer, configuration parameter to read/write (see Configuration Parameters,
Table 9)
3
1 byte
Read/Write/Response
0 = Read Configuration Parameter, 1 = Write configuration parameter, 2 = Response from
Speed Sensor
4
Up to
5 bytes
Data
Configuration parameter specific data (see Configuration Parameters, Table 9)
Note: Data may be omitted or set to all 1’s for read request
1. After receiving a valid read message, the speed sensor will send a response message with the Destination Address (DA) set to the Source Address of the
requestor. For write messages, Speed Sensor will not give response or acknowledgement.
2. When sending a read/write message the Destination Address (DA) will be the Source Address of the Speed Sensor receiving the message. Some examples for
the configuration parameters read/write messages can be found at the end of the document.