![Parker GS100 User Manual Download Page 11](http://html.mh-extra.com/html/parker/gs100/gs100_user-manual_755506011.webp)
Parker Hannifin Corporation
– GS100 User Manual
10
CAN (SAE J1939) communication characteristics
CAN baud rate
CAN
baud
125
250
1000
KBPS
CAN Message data Rate
MD
r
10
50
2000
ms
Number of Output Pulse Samples
for Speed and direction
N
ssD
1
8
15
-
Speed output Tolerance
-2
-
2
%
Tooth Pulse Counter
[5]
P
counter
0
-
1,000,000
-
CAN Message Counter
[5]
M
counter
0
-
7
-
CAN default Source Address
SA
d
0x80
-
CAN default Broadcast PGN
B
PGN-d
0xFF75
-
[1]
Supply current is measured
with 6.8kΩ pull-up resistor connected to an external 5V supply.
[2]
Airgap is dependent on the target geometry and material dependent and should be independently characterized.
[3]
The sensor broadcasts 0Hz CAN output for any speeds below 10Hz.
[4]
This reading was measured when sensor was connected to a 12V
power supply with a 6.8KΩ pull-up to external 5V
[5]
Once it reaches the max value, this value falls back to 0 and starts counting again.
Product Features
General Notes
Mounting Fastener Torque
11.3 N-m
O-ring
AS-568A-114 or equal
Input and Output Wires
20 AWG SXL
Connector
DTM04-6P Deutsch
Weight
0.10 kg
Environmental
EMC
EMC Emissions - Level 1 (ANSI/ASAE EP455 R2008)
EMC Susceptibility - Level 3 (ISO 13766 2006)
ESD
Direct Contact: ± 8KV
Air: ± 15KV
EMI
ISO 7637-2 and 3 transients
Load Dump
ISO 7637-2 2004 Pulse 5a, +87V peak 400ms duration
Climate
IP67 and IP69K rated
Chemical
Liquids (resistance) standard automotive
Certifications
EU RoHS 2
CE
EN61000-6-2, EN61000-6-4, EN 13309, ISO 13766-1, ISO13766-2, ISO 14982