background image

 Motor Output Connections

 AC Input Connections

 26 Pin MOTOR FEEDBACK Connector

 +24VDC/Relay Connector

#8 (M4)
spade fork, 
0.325" max. width
20 in-lbs nominal,
24 in-lbs max.

Drive terminals: 

Mating terminals: 

Tightening torque: 

GT6K Stepper

Quick Reference Guide

 Multiple Drive Connections

For multiple drives, use a
single point safety earth

Encoder Z–
Encoder Z+
Encoder B–
Encoder B+
Encoder A–
Encoder A+
Encoder Ground
Encoder Ground
E5V
E5V

13
12
11
10

9
8
7
6
5
4
3
2
1

26
25
24
23
22
21
20
19
18
17
16
15
14

Male
Pins

To configure drive parameters, connect a PC  to this port. 
Use Motion Planner for drive configuration. 
Enabling Ethernet will disable the COM1 port.

 RS-232/485 Connector – COM1 – Port 1

6

7

8

9

2

1

3

4

5

Rx Tx

Gnd

RS-232 Connections

2

1

3

4

5

6

7

8

9

Rx-

(RD A)

Tx-
(TD A)

Gnd

Rx+

(RD B)

Tx+

(TD B)

RS-485 Connections

Male
Pins

Connect an RP240, or use this port for RS-232. 
Download Operating System through this port only. 
Ethernet and COM2 can both be active at the same time.

 RS-232 Connector – COM2 – Port 2

6

7

8

9

2

1

3

4

5

Rx Tx

Gnd

+5VDC

RS-232 Connections

Left  Right 

  Indicated State:

Red Grn  

+24VDC 

only 

Red Yel  

AC 

only 

Grn (flash)   

Motion in progress
Autorun mode
Initializing

Red Off

Drive not enabled or
Drive faulted

Yellow/Green

Green/Red

LEDs

 50 Pin DRIVE I/O Connector

Output Ground

Output 6
Output 5

Output Ground

Output 4
Output 3

Output Ground

Output 2

Output Ground

Output 1

Input/Limit Ground

Input 3

(Trig B)  Input 2
(Trig A)  Input 1

Input/Limit Ground

(Master Trig)  Input 5

Input 4

CNTRL-P: Inputs 1 – 5

Input/Limit Ground

(Home)  Limit 3

Input/Limit Ground

(Neg)  Limit 2

(Pos)  Limit 1

CNTRL-P: Lim 1 –  3

VINref

Analog Ground
Analog Input–
Analog Input+
Analog Output B
Analog Output A
Digital Ground
Reserved
Reserved
Direction– Out
Di Out
Step– Out
Step+ Out
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Digital Ground
Digital Ground
Reserved
Reserved
Reset
Digital Ground
Enable

25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10

9
8
7
6
5
4
3
2
1

25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10

9
8
7
6
5
4
3
2
1

50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26

GT6K-L5/L8
at 120VAC

95 – 132VAC

N/C

N

L1

Fuses

Re24VDC input.  
19.2 – 28.8 VDC. 
500 mA minimum.

When drive is enabled, it 
holds relay closed. 

Relay rating: 5A at 24VDC  
or 120VAC.

If drive is faulted or disabled, 
relay will open. (Typical use: 
control of motor brake.)

+24V   DC

24V RTN

RELAY COM

RELAY  N.O.

 Ethernet Connector

RJ-45 connector for 10Base-T (10Mbps
twisted pair) TCP/IP protocol.
Default address is 192.168.10.30.
Green LED on = Connection OK;
Yellow LED on (flash) = Transmitting.

 Expansion I/O Connector

Connect as many as eight EVM32-II I/O modules in series, 
for up to 256 additional I/O points.

 Master Encoder Connector

Connect an encoder for Following only; 
not for servo feedback or stepper stall
detect.

Pins 11 - 26 are
not used by the 
GT6K

R

S

-23

2

ETHERNET

+24V   DC

MO

T

O

R

1

2

0

V

GT6K

Gemini

Stepper

A+

A–

B+

B–

Motor Cable

DRIVE
TERMINALS

A+

A–

B+

B–

Earth

MOTOR
WIRES

#8 (M4)
spade fork, 
0.325" max. width
20 in-lbs nominal,
24 in-lbs max.

Drive terminals: 

Mating terminals: 

Tightening torque: 

www.comoso.com

Reviews: