13
DTX10 - DTX100 USER GUIDE
of time for the sensor to dry out and come to equilibrium with the system.
The sensor will also become saturated to atmospheric conditions if the air system is shut down
and allowed to depressurize. Upon restart of the system, the dew point may appear to be poor,
even though the dryer may be producing clean, dry air.
Although the probe can be exposed to occasional, brief periods of liquid saturation, it can not
be exposed to continuous wet conditions. If your dryer is over loaded and saturated, or if it will
be shut down for an extended period of time; remove or isolate the probe until the problem is
resolved. Refer to the separate DDS section for more detailed information.
IMPORTANT!
Demand Control Cycles can not be used together! Please consult factory to ensure
proper use of any of the nonstandard cycles.