background image

1

 

1 Safety Information

Do not operate this equipment until the safety information and instructions in this user guide have been read and understood by all 
personnel concerned.

USER RESPONSIBILITY

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE 
DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, its subsidiaries and authorised distributors provide product or system 
options for further investigation by users having technical expertise.   

The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring 
that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyse all aspects 
of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalogue and in 
any other materials provided from Parker or its subsidiaries or authorised distributors.   

To the extent that Parker or its subsidiaries or authorised distributors provide component or system options based upon data or specifications 
provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and 
reasonably foreseeable uses of the components or systems. 

Only competent personnel trained, qualified, and approved by Parker Hannifin should perform installation, commissioning, service and repair 
procedures.

This equipment is for indoor use only. Do not operate outdoors.

With the exception of oxygen, any gas can cause asphyxiation in high enough concentrations. Always ensure that the generator is operated in 
a well ventilated area and all of the vent ports on the rear of the generator are kept clear and free from blockages.

Use of the equipment in a manner not specified within this user guide may result in an unplanned release of pressure, which may cause serious 
personal injury or damage.

When handling, installing or operating this equipment, personnel must employ safe engineering practices and observe all related regulations, 
health & safety procedures, and legal requirements for safety.

The components within the generator may contain high pressure. These should not be modified or tampered with in any way as serious injury 
could occur.

Ensure that the equipment is depressurised and electrically isolated, prior to carrying out any of the scheduled maintenance instructions 
specified within this user guide.

Parker Hannifin can not anticipate every possible circumstance which may represent a potential hazard. The warnings in this manual cover the 
most known potential hazards, but by definition can not be all-inclusive. If the user employs an operating procedure, item of equipment or a 
method of working which is not specifically recommended by Parker Hannifin the user must ensure that the equipment will not be damaged or 
become hazardous to persons or property.

Most accidents that occur during the operation and maintenance of machinery are the result of failure to observe basic safety rules and 
procedures. Accidents can be avoided by recognising that any machinery is potentially hazardous.

Note:

 Any interference with the calibration warning labels will invalidate the gas generator's warranty and may incur costs for the recalibration of 

the gas generator. 

Should you require an extended warranty, tailored service contracts or training on this equipment, or any other equipment within the Parker 
Hannifin range, please contact your local Parker Hannifin office. 

Details of your nearest Parker Hannifin sales office can be found at www.parker.com/dhfns

Retain this user guide for future reference.

Summary of Contents for domnick hunter UHP10ZA-S

Page 1: ...ro Air Generator UHP 10ZA S UHP 300ZA S Original Language User Guide aerospace climate control electromechanical filtration fluid gas handling hydraulics pneumatics process control sealing shielding E...

Page 2: ...ccordance with such instruction and with good practice The company shall not be under any liability whatsoever under the warranty if before giving notification in writing to the company as aforesaid t...

Page 3: ...layout 8 3 1 1 Installation Parts 8 3 2 Connecting the generator 9 3 2 1 Electrical supply 9 3 2 2 Stacking the Generator 9 4 Operating the equipment 10 4 1 Overview of the generator 10 4 2 Starting t...

Page 4: ......

Page 5: ...ed area and all of the vent ports on the rear of the generator are kept clear and free from blockages Use of the equipment in a manner not specified within this user guide may result in an unplanned r...

Page 6: ...be worn Gloves must be worn Warning Generator must be shut down and depressurised before performing any maintenance Refer to manual Caution Hot components enclosed Do not remove the cover until the u...

Page 7: ...cification is valid when the equipment is located installed operated and maintained as specified within this user guide Parameter Units UHP 10ZA S 35ZA S 50ZA S 75ZA S 150ZA S 200ZA S 300ZA S General...

Page 8: ...flicker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject to conditional connection This equipment has been tested to and complies with the following...

Page 9: ...A S 325 12 8 340 13 4 425 16 7 219 8 6 10 2 22 5 35ZA S 455 17 9 340 13 4 425 16 7 330 13 0 14 2 31 3 50ZA S 455 17 9 340 13 4 425 16 7 330 13 0 14 2 31 3 75ZA S 455 17 9 340 13 4 425 16 7 330 13 0 14...

Page 10: ...s final location installation site and left to stabilise prior to unpacking Failure to do this could cause condensing humidity and potential failure of the generator 2 5 2 Unpacking Once ready to inst...

Page 11: ...llowed Class 1 Oil In each cubic metre of compressed air not more than 0 01 mg of oil is allowed Note This is the combined level for aerosol liquid and vapour ISO 8573 1 2010 Class 2 2 1 can be achiev...

Page 12: ...XPFA BP 1 8 OD Tube Non Return Valve 2A C2L 1 BN BP 1 4 OD Tube Non Return Valve 4A C4L 1 BN B 1 8 OD Tube Equal Tee 2ET2 B 1 4 OD Tube Equal Tee 4ET4 B 1 8 OD Tube Pressure Relief Valve This relief v...

Page 13: ...Generator The generator may be re configured so that the Parker Hannifin H and HMD range of hydrogen generators may be stacked safely on top of it To re configure the generator unlock the two retaini...

Page 14: ...or reaches the set temperature open the isolation valve located downstream of the generator Note The temperature may fluctuate up to 1 of the set temperature 6 The application instrument is now being...

Page 15: ...r leaks within the system Generator Check the mains supply cable for damage Generator Ensure there is ventilation clearance around generator Generator Replace the inlet and outlet filters Recommended...

Page 16: ...ck nut No 10 self tapping screw 120 V Fan Service Kit 606272526 606272526 Description Catalogue Number Technical Reference Contents 230 V Catalyst UHP 10ZA S 606272511 606272511 Catalyst assembly comp...

Page 17: ...Name Address Telephone Fax Contact Name Date of Commission Service Interval Months Hours Date Serviced By Comments Print Sign 6 4 000 12 8 000 18 12 000 24 16 000 30 20 000 36 24 000 42 28 000 48 32...

Page 18: ...sensor is open circuit Contact Parker Hannifin Indication Possible fault Condition Action Poor quality results downstream monitoring The generator is not powered Check the following 1 the generator i...

Page 19: ...supply cable is not damaged Contact Parker Hannifin Faulty controller or internal wiring fault Contact Parker Hannifin Indication Possible fault Condition Action Downstream monitoring Faulty cooling...

Page 20: ...r com NL The Netherlands Oldenzaal Tel 31 0 541 585 000 parker nl parker com NO Norway Asker Tel 47 66 75 34 00 parker norway parker com PL Poland Warsaw Tel 48 0 22 573 24 00 parker poland parker com...