Installation & Commissioning
EN
7
3 Installation & Commissioning
3.1 Recommended system layout
The dryer should be installed with the correct pre-filtration and condensate management equipment to meet both the specification and local
environmental requirements.
Referring to diagram A4 in Annex A, the following equipment is recommended to meet these requirements:
* These filters may not have been supplied with the dryer but are essential in order to achieve the ISO classifications stated below.
3.1.1 Air Quality
A dryer operating with a pressure dewpoint of -40
o
C and installed with AO and AA grade filtration on the inlet and an AR grade filter at the outlet
can achieve ISO 8573.1:2010 Class 2.2.2
The optional -70
o
C dryer installed with the above filtration can achieve ISO 8573.1:2010 Class 2.1.2
ISO 8573.1:2010 is an international standard that specifies the purity classes of compressed air with respect to solid particulates, water and oil.
ISO 8573.1:2010 class 2.2.2 equates to the following:
Class 2 (Solid Particulate)
In each cubic metre of compressed air, not more than 400,000 particles in the 0.1 - 0.5 micron size range are allowed.
In each cubic metre of compressed air, not more than 6,000 particles in the 0.5 - 1 micron size range are allowed.
In each cubic metre of compressed air, not more than 100 particles in 1 - 5 micron size range are allowed.
Class 2 (Water)
A pressure dewpoint of -40
o
C or better is required.
No liquid is allowed
Class 2 (Oil)
In each cubic metre of compressed air, not more than 0.1 mg of oil is allowed.
Note: This is the combined level for aerosol, liquid and vapour.
ISO 8573.1:2010 class 2.1.2 equates to the following:
Class 2 (Solid Particulate)
In each cubic metre of compressed air, not more than 400,000 particles in the 0.1 - 0.5 micron size range are allowed.
In each cubic metre of compressed air, not more than 6,000 particles in the 0.5 - 1 micron size range are allowed.
In each cubic metre of compressed air, not more than 100 particles in 1 - 5 micron size range are allowed.
Class 1 (Water)
A pressure dewpoint of -70
o
C or better is required.
No liquid is allowed
Class 2 (Oil)
In each cubic metre of compressed air, not more than 0.1 mg of oil is allowed.
Note: This is the combined level for aerosol, liquid and vapour.
Only competent personnel trained, qualified, and approved by Parker domnick hunter should perform installation,
commissioning and service procedures.
Ref
Description
Ref
Description
1
Compressor
5
Dryer
2
Wet air receiver
6
* Dust filter (AR Grade)
3
* General purpose filter (AO Grade)
7
Isolation valves
4
* High efficiency filter (AA Grade)
8
Outlet to application
Summary of Contents for Domnick Hunter PNEUDRI DME012
Page 123: ...EN EL 122 1 1 1 2 DRYFIL DRYFIL DRYFIL DRYFIL DRYFIL Q DRYFIL Conformit Europ enne...
Page 128: ...9 EN EL 127 3 2 3 3 AA AO AR 5 DDS AR 5 4 mm DDS P T F E AA Q 1 AO 4 AR 2 AA 5 DDS 3 6...
Page 131: ...9 EN EL 130 5 9 5 2 Parker domnick hunter 5 1 5 2 _ _ 3 _ 6 _ 12 _ 36 Q 9 9 DDS 9 9 9 E...
Page 133: ...9 EN EL 132 5 4 9 9 9 9 4 000 8 000 16 000 20 000 24 000 28 000 32 000 36 000 40 000...
Page 135: ...EN EL 134 6 2 6 3 9 9 12 Parker domnick hunter O 9 O...
Page 288: ...EN RU 287 1 1 1 2 DRYFIL 3 3 DRYFIL 3 DRYFIL DRYFIL DRYFIL DRYFIL 3 Conformit Europ enne...
Page 293: ...EN RU 292 3 2 3 3 AA AO AR A5 A DDS AR A5 8 4 DDS 3 8 1 5 4 AR 2 3 55 5 4 DDS 3 6...
Page 298: ...EN RU 297 5 4 4 000 8 000 16 000 20 000 24 000 28 000 32 000 36 000 40 000...
Page 300: ...EN RU 299 6 2 6 3 12 Parker domnick hunter...
Page 346: ...DME012 DME080 345...
Page 348: ...DME012 DME080 347 A2 DME012 DME040 A C D B A B DME050 DME080...
Page 349: ...MT 348 A3 A4 DME012 DME040 DME050 DME080 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 7 3 4 6 7 5 2 8...
Page 350: ...DME012 DME080 349 A5 1 6 3 4 6 5 2...
Page 351: ...MT 350...