Parker domnick hunter DNC1050 User Manual Download Page 12

DNC200 - DNC1200 USER GUIDE

12 - Rev. D

10.   

Technical Specifications

 

10.1    Air-Cooled Units

Model

Nominal

Capacity

(scfm)

Pipe

Size

Drain

Electrical 

Supply

Recommended 

Pre-Filter

Replacement 

Element

Recommended 

After-Filter

Replacement 

Element

DNC200

200

2”

 NPT

1/4”

NPT

230V/1PH/60Hz

AO030GNFI

030AO

AA030GNFI

030AA

DNC250

250

2” 

NPT

1/4”

 NPT

230V/1PH/60Hz
230V/3PH/60Hz
460V/3PH/60Hz
575V/3PH/60Hz

AO035GNFI

035AO

AA035GNFI

035AA

DNC325

325

2” 

NPT

1/4” 

NPT

230V/1PH/60Hz
230V/3PH/60Hz
460V/3PH/60Hz
575V/3PH/60Hz

AO035GNFI

035AO

AA035GNFI

035AA

DNC400

400

2”

 NPT

1/4” 

NPT

230V/3PH/60Hz
460V/3PH/60Hz
575V/3PH/60Hz

AO040HNFI

040AO

AA040HNFI

040AA

DNC500

500

2” 

NPT

1/4”

 NPT

230V/3PH/60Hz
460V/3PH/60Hz
575V/3PH/60Hz

AO045HNFI

045AO

AA045HNFI

045AA

DNC700

700

3” 

NPT

1/4” 

NPT

230V/3PH/60Hz
460V/3PH/60Hz
575V/3PH/60Hz

AO050JNFI

050AO

AA050JNFI

050AA

DNC850

850

3” 

NPT

1/4” 

NPT

230V/3PH/60Hz
460V/3PH/60Hz
575V/3PH/60Hz

AO050JNFI

050AO

AA050JNFI

050AA

DNC1050

1050

3” 

NPT

1/4” 

NPT

230V/3PH/60Hz
460V/3PH/60Hz
575V/3PH/60Hz

AO055JNFI

055AO

AA055JNFI

055AA

DNC1200

1200

3” 

NPT

1/4” 

NPT

230V/3PH/60Hz
460V/3PH/60Hz
575V/3PH/60Hz

AO055JNFI

055AO

AA055JNFI

055AA

Ambient Temperature (C1) air-cooled only

Inlet Temperature (C2)

Inlet Pressure (C3)

Flow correction factors

To obtain dryer capacity at new conditions, multiply capacity x C1 x C2 x C3.

°F

80

90

95

100

105

110

115

°C

27

32

35

38

41

43

46

Factor

1.12

1.08

1.05

1.00

0.95

0.90

0.84

°F

80

85

90

95

100

105

110

115

120

130

140

°C

27

29

32

35

38

41

43

46

49

54

60

Factor

1.22

1.22

1.22

1.10

1.00

0.92

0.83

0.76

0.69

0.56

0.46

psi g

50

60

75

80

90

100

110

125

130

140

150

bar g

3.5

4.1

5.2

5.5

6.2

6.9

7.6

8.6

9.0

9.7

10.3

Factor

0.80

0.84

0.90

0.92

0.96

1.00

1.01

1.02

1.03

1.04

1.05

Summary of Contents for domnick hunter DNC1050

Page 1: ...domnick hunter Non Cycling Refrigerated Dryer User Guide Rev D Models DNC200 DNC1200...

Page 2: ...trols Standard on all models 5 4 Start Up Procedures 6 4 1 When Operating Dryer 6 5 Routine Maintenance 7 6 Maintenance Schedule 8 6 1 Maintenance Procedures 8 7 Troubleshooting Service 9 7 1 Refriger...

Page 3: ...n ambient temperature between 41 100 F 5 38 C and free from explosive and corrosive fumes Three 3 feet 92cm of space must be allowed between all open grills If the dryer is installed in a confined are...

Page 4: ...ions To be performed by a qualified person only Risk of serious injury or death Observe Lock out Tag Out Procedure Disconnect lock out and tag all power at source prior to attempting repairs or adjust...

Page 5: ...D 3 Controls Standard on all models Dryer ON OFF Switch Dryer POWER Light HIGH REFRIGERANT PRESSURE ALARM LOW REFRIGERANT PRESSURE ALARM DEWPOINT TEMPERATURE INDICATOR Adjustable time drain module mou...

Page 6: ...s may be the result of shipping damage see section 1 0 4 Switch unit on ON OFF indicator will light 5 Do not pass air through the dryer until it stabilizes Typically 5 minutes 6 Once the dryer stabili...

Page 7: ...bris that might accumulate Remove any debris immediately The strainer should be checked weekly Pre filtration per installation instructions Parker pre filter should be installed directly upstream from...

Page 8: ...ndensing coil fins air cooled units only Dryer Compressor oil level sight glass 250 to 1200 SCFM Filtration Depressurized dryer Replace pre and after filter elements Dryer Check for refrigerant leaks...

Page 9: ...for proper voltage Turn dryer on Check fuses and replace if necessary 2 Clean strainer 3 Reduce load 4 Check wiring voltage Replace if necessary 5 Close bypass High Dewpoint 1 Excessive thermal load 2...

Page 10: ...500 230 3 60 11 4 57 1 1 2 1 5 16 1 25 460 3 60 5 4 23 1 0 6 1 5 7 9 10 575 3 60 5 4 23 1 0 6 1 5 6 3 10 DNC700 230 3 60 15 7 98 1 3 1 2 23 2 35 460 3 60 7 1 38 1 1 5 1 2 11 0 15 575 3 60 7 1 38 1 1 5...

Page 11: ...r XF0325 NCR XF0500 NCR XF1000 NCR 6 Expansion valve DP34181 404 DP34182 404 1 DP34183 404 DP34185 404 7 Refrigerant filter DP28125 DP28135 8 Hot gas bypass valve DP36062 4 DP36062 2 9A Fan 1 pressure...

Page 12: ...4 NPT 230V 3PH 60Hz 460V 3PH 60Hz 575V 3PH 60Hz AO050JNFI 050AO AA050JNFI 050AA DNC850 850 3 NPT 1 4 NPT 230V 3PH 60Hz 460V 3PH 60Hz 575V 3PH 60Hz AO050JNFI 050AO AA050JNFI 050AA DNC1050 1050 3 NPT 1...

Page 13: ...DNC200 DNC1200 USER GUIDE 13 Rev D 11 Associated Drawings REF ADE11374...

Page 14: ...DNC200 DNC1200 USER GUIDE 14 Rev D REF ADE11374...

Page 15: ...DNC200 DNC1200 USER GUIDE 15 Rev D REF ADE11374...

Page 16: ...DNC200 DNC1200 USER GUIDE 16 Rev D REF ADE11374...

Page 17: ...DNC200 DNC1200 USER GUIDE 17 Rev D REF ADE11374...

Page 18: ...xploded Views DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 200 EXPLODED ASSY AD11511 2 1 1 16...

Page 19: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 250 EXPLODED ASSY AD11510 2 1 1 15 2014 26...

Page 20: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 325 EXPLODED ASSY AD11509 2 1 1 15 2014 26...

Page 21: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 400 EXPLODED ASSY AD11508 2 1 1 15 2014 26...

Page 22: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 500 EXPLODED ASSY AD11507 2 1 1 14 2014 26...

Page 23: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 700 EXPLODED ASSY AD11506 2 1 1 14 2014 12...

Page 24: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 850 EXPLODED ASSY AD11505 2 1 1 14 2014 12...

Page 25: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 16 NON CYCLING 1050 EXPLODED ASSY AD11504 2 1 1 14 2014 19...

Page 26: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 16 NON CYCLING 1200 EXPLODED ASSY AD11503 2 1 1 14 2014 19...

Page 27: ...dicate a response on a scale of 1 being the lowest to 5 being the highest Condition of Arrival Ease of Installation Ease of Start Up Product Quality Technical Assistance Clarity of Instruction Warrant...

Page 28: ...nit Padova Italy 39 049 9712 111 www parker com hzd Hiross Zander Essen Business Unit Essen Germany 49 2054 9340 www parker com hzd Engine Filtration Water Purification Racor Dewsbury England 44 0 192...

Reviews: