Parker D41FE Operation Manual Download Page 6

6

Pilot Operated Proportional DC Valve 
Series D*1FE

Operation Manual

Parker Hannifin Corporation

D_1FE 5715-688 UK CM 18.01.2019

Technical Data

General
Design

Proportional directional control valve, pilot operated

Actuation

VCD

®

-actuator

Size

NG10 (CETOP 05) NG16 (CETOP 07) NG25 (CETOP 08) NG32 (CETOP 10) 

D31

D41

D81 / D91

D111

Mounting Interface

DIN 24340 / ISO 4401 / CETOP RP121 / NFPA

Mounting position

unrestricted

Ambient temperature

[°C] -20...+50

MTTF

D

 value

[years] 50

Weight

[kg]

11.3

14.2

23.5

64.5

Vibration resistance

[g] 10 Sinus 5...2000 Hz acc. IEC 68-2-6

10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36
15 Shock acc. IEC 68-2-27

Hydraulic

Max. operating pressure

[bar]

Internal pilot drain P, A, B, X  350; T, Y 35
External pilot drain P, A, B, T, X  350; Y 35

Fluid

Hydraulic oil acc. DIN 51524 ... 51535, other on request

Fluid temperature

[°C] -20...+60 (NBR: -25...+60)

Viscosity   permitted 
 recommended

[cSt]/[mm2/s]
[cSt]/[mm2/s]

20...400
30...80

Filtration

ISO 4406; 18/16/13

Electrical 
Duty ratio

[%] 100

Protection class

IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)

Supply voltage / ripple

[V] 22...30, ripple < 5 % eff., surge free

Current consumption max.

[A] 3.5

Pre-fusing

[A] 4.0 A medium lag

Input signal   Code K (B)   Voltage
 

 Impedance

[V]

[kOhm]

+10...0...-10, ripple < 0.01 % eff., surge free, 0...+10 V P–>A (P–>B)
100

   

Code E  

Voltage

 

 

Impedance  

[mA]

[Ohm]

+20...0...-20, ripple < 0.01 % eff., surge free, 0...+20 mA P–>B
< 250

    

Code S 

Current

 

 Impedance

[mA]

[Ohm]

4...12...20, ripple < 0.01 % eff., surge free, 12...20 mA P–>A
< 3.6 mA = enable off, > 3.8 mA = enable on acc. NAMUR NE43
< 250

Input Capacitance typ.

[nF] 1

Differential input max. 
 

Code 0

[V] 30 for terminal D and E against PE (terminal G)

11 for terminal D and E against 0V (terminal B)

    

Code 5

[V] 30 for terminal 4 and 5 against PE (terminal 

W

 )

11 for terminal 4 and 5 against 0V (terminal 2)

    

Code 7

[V] 30 for terminal D and E against PE (terminal G)

Enable signal Code 5/7

[V] 5...30, Ri > 8 kOhm

Diagnostic signal

[V] +10...0...-10 / +12.5 V, rated max. 5 mA

EMC

EN 61000-6-2, EN 61000-6-4

Electrical connection  

   

    

 

 

Code 0/7

6 + PE acc. EN 175201-804

 

Code 5

11 + PE acc. EN 175201-804

Wiring min.   Code 0/7

7 x 1.0 AWG16 overall braid shield

 

Code 5

8 x 1.0 AWG16 overall braid shield

Wiring lenght max.

[m] 50

Summary of Contents for D41FE

Page 1: ...e Operation Manual Series D 1FE Pilot Operated Design 30 Parker Hannifin Manufacturing Germany GmbH Co KG Industrial Systems Division Europe Gutenbergstr 38 41564 Kaarst Germany Tel 49 181 99 44 43 0...

Page 2: ...of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application fol...

Page 3: ...g Name Plates 7 Work at the Valve 7 3 Important Details 7 Intended Usage 7 Common Instructions 7 Liability 7 Storage 7 4 Mounting Installation 8 Scope of Supply 8 Mounting 8 Operation Limits 8 Pressur...

Page 4: ...onic option NG06 pilot Proportional control High repeatability Pilot connections D 1 F C E Design series not required for ordering For details see Catalogue HY11 3500UK For details see Catalogue HY11...

Page 5: ...e valve The most important features are high dynamic actuator principle with special designed electronic driver closed loop controlled pilot valve and main spool Ensured fail safe behaviour constant c...

Page 6: ...tion class IP65 in accordance with EN 60529 with correctly mounted plug in connector Supply voltage ripple V 22 30 ripple 5 eff surge free Current consumption max A 3 5 Pre fusing A 4 0 A medium lag I...

Page 7: ...ded The manufacturer is not liable for warranty claims resulting from this Common Instructions We reserve the right for technical modifications of the described product Illustrations and drawings with...

Page 8: ...sscross with the following torque values D31FE 13 2 Nm D41FE 13 2 63 Nm D81 91FE 108 Nm D111FE 517 Nm Insufficient condition of the valve mounting surface migth create malfunction Incorrect mountingre...

Page 9: ...50 m For cable lengths 50 m consult Parker The connection cable is coupled to the female connector by solder joints Skinning lengths for the connecting cable The connection Code 5 requires a 11 PE fem...

Page 10: ...on observanceofthisinstruc tion may create irreparable damage of valve resp incorporated system parts The backshell nut of the cable gland has to be tighten with a suitable tool The target value for t...

Page 11: ...eries D 1FE Operation Manual 11 Parker Hannifin Corporation D_1FE 5715 688 UK CM 18 01 2019 Wiring Code 0 6 PE acc EN 175201 804 Code 5 11 PE acc EN 175201 804 Code 7 6 PE acc EN 175201 804 enable 1 D...

Page 12: ...e valve will reach its powerdownpositionspring actuatedindependently from the command signal value The enable function represents no safety ar rangementagainstunwantedvalveopera tion in terms of rules...

Page 13: ...nge filtration review valve flushing The overcurrent shutoff condition may be resetted by the actions below Code 0 Temporary disconnection of the supply voltage Code 5 Temporary disconnection of the e...

Page 14: ...ve parameter The chosen parameters may be optionally stored on the PC via the File menu with the menu item Save as data retrieving is always possible via the function Load file Extended functions The...

Page 15: ...pprox 0 5 Hz slowly green disable valve OK approx 1 Hz fast green valve error approx 10 Hz very fast green Closer information can be can be displayed via the ProPxD Parametrier software LED Error code...

Page 16: ...ustment of maximum signal span for negative output signal To match the command signal span to the valve operating range P7 MIN Adjustment of stroke step for valve side A at min operating threshold To...

Page 17: ...ault report about diagnosis 768 J8 Min supply voltage supervision Adjustment of the minimal supply voltage Below this supply voltage the valve switches off with an error message J9 Relay time out off...

Page 18: ...will be lost In principle parameters dedicated to a type which deviates from the connected valve may be edited However for data transmitting the correct valve has to be connected If parameters will b...

Page 19: ...pending on travel direction speed too low drifting without command poor dynamic possible reasons for malfunction corrective actions X hydraulic pump resp motor defective replace hydraulic pump resp mo...

Page 20: ......

Reviews: