Installation & Operation
Valve should be installed with reasonable accessibility for service
whenever possible - repair service kits are available. Keep pipe
or tubing lengths to a minimum with inside clean and free of
dirt and chips. Pipe joint compound should be used sparingly
and applied only to the male pipe - never into the female port.
Do not use PTFE tape to seal pipe joints - pieces have a
tendency to break off and lodge inside the unit, possibly causing
malfunction.
Valves will operate when mounted in any position. They are
also suitable for vacuum service. A pilot pressure of 207 kPa
(30 psig) or more is recommended to operate these valves.
Pilot pressure does not need to be increased as line pressure
is increased.
Series C & CW (wall mounting) valves can be operated either
normally closed to pressure or normally open to pressure.
Connect inlet to port “A” for normally closed valve. Port “B” is
exhaust. Connect inlet to port “B” for normally open valve. Port
“A” is exhaust. Plug exhaust port for 2-Way operation.
Factory Pre-Lubrication - All valves are pre-lubricated at
assembly with a petroleum based grease. Filtered and lubricated
air is necessar y for maximum valve life and minimum
maintenance.
Service Procedure
!
Caution: Shut off air supply and exhaust pressure trapped
within the unit before servicing.
Servicing Valve & Actuator Assemblies:
To remove the
pressure actuator assembly (item 11) from the
valve body, unscrew the mounting screws (item 15). Remove
the piston and lip seal from the piston cap (item 14). To remove
the spool, spool guide, and seals from the valve body, unscrew
the end plug using a 3/8" Allen wrench. Then gently press on
the “pin” side of the spool until it slides out of the valve body.
Introduction
Follow these instructions when installing, operating, or servicing
the product.
Application Limits
These products are intended for use in general purpose
compressed air systems only.
Operating Inlet Pressure Range:
kPa
psig
bar
Minimum
0
0
0
Maximum
1030
150
10.3
Ambient Temperature Range:
-18°C to 71°C (0°F to
160°F)
Symbols
➤
A
B
➤
➤
➤
➤
A
B
Normally
Closed
Normally
Open
Installation & Service Instructions
V-225CP
C10 & CW10 Series Valves
ISSUED: September, 2000
Supersedes: October, 1995
ECN# P27805
Pneumatic Division North America
Richland, Michigan 49083
!
!
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or
system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application,
including consequences of any failure and review the information
concerning the product or systems in the current product catalog. Due
to the variety of operating conditions and applications for these products
or systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by Parker Hannifin Corporation and its subsidiaries at any
time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.